Characteristics of Standard Capsule-Type PtCo Resistance Thermometers Between 0.65 K and 25 K

被引:0
|
作者
T. Shimazaki
T. Nakano
S. Takasu
机构
[1] AIST,National Metrology Institute of Japan (NMIJ)
来源
关键词
Joule–Thomson cryocooler; Platinum–cobalt (PtCo) resistance thermometer; Pulse tube refrigerator; Reproducibility; Stability;
D O I
暂无
中图分类号
学科分类号
摘要
Standard capsule-type platinum–cobalt (PtCo) resistance thermometers represent one of the few types of resistance thermometers that have been developed for precise thermometry in the cryogenic temperature range. These thermometers remain sensitive even at 0.65 K, which is the lower limit of the ITS-90. Standard capsule-type rhodium–iron (RhFe) resistance thermometers are another type of resistance thermometer intended for use in this temperature range and have been well characterized and are the de facto standard worldwide. Existing data show RhFe resistance thermometers are more reproducible than the corresponding PtCo resistance thermometer. However, it has become difficult to obtain brand-new standard capsule-type RhFe resistance thermometers since their production was discontinued in the early 2000s. Unfortunately, information regarding the characteristics of standard capsule-type PtCo resistance thermometers is limited compared to that available for RhFe resistance thermometers. In this study, the characteristics of two standard capsule-type PtCo resistance thermometers between 0.65 K and 25 K were investigated. Because the resistance versus temperature curves for these thermometers over this temperature range exhibit two inflection points, setting break points near each of the inflection points was found to be beneficial during polynomial curve fitting to obtain mK-level precision. Special attention was paid to the reproducibility of these thermometers, and it was observed that the reproducibility of one of the thermometers within the cryogenic temperature range was ±0.5 mK over 6 years, while the second thermometer showed a larger variation. Similar trends in the resistance characteristics of the two thermometers were observed at the triple point of water.
引用
收藏
相关论文
共 38 条
  • [1] Characteristics of Standard Capsule-Type PtCo Resistance Thermometers Between 0.65 K and 25 K
    Shimazaki, T.
    Nakano, T.
    Takasu, S.
    [J]. INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2017, 38 (07)
  • [2] CCT-K2: key comparison of capsule-type standard platinum resistance thermometers from 13.8 K to 273.16K
    Steele, AG
    Fellmuth, B
    Head, DL
    Hermier, Y
    Kang, KH
    Steur, PPM
    Tew, WL
    [J]. METROLOGIA, 2002, 39 (06) : 551 - 571
  • [3] Normal and Anomalous Self-Heating in Capsule-type Resistance Thermometers in the Range 1 K to 273 K
    Tew, W. L.
    Meyer, C. W.
    [J]. TEMPERATURE: ITS MEASUREMENT AND CONTROL IN SCIENCE AND INDUSTRY, VOL 8, 2013, 1552 : 451 - 456
  • [4] CCT-K2.3: NRC/NMi-VSL bilateral comparison of capsule-type standard platinum resistance thermometers from 13.8 K to 273.16 K
    Hill, K. D.
    Peruzzi, A.
    Bosma, R.
    [J]. METROLOGIA, 2012, 49
  • [5] Final report on CCT-K2.5: NRC/NMIJ/INRIM comparison of capsule-type standard platinum resistance thermometers from 13.8 K to 273.16 K
    Hill, K. D.
    Nakano, T.
    Steur, P.
    [J]. METROLOGIA, 2015, 52
  • [6] CCT-K2.4: NRC/INTiBS/LNE-Cnam trilateral comparison of capsule-type standard platinum resistance thermometers from 13.8 K to 273.16 K
    Hill, K. D.
    Szmyrka-Grzebyk, A.
    Lipinski, L.
    Hermier, Y.
    Pitre, L.
    Sparasci, F.
    [J]. METROLOGIA, 2012, 49
  • [7] Comparison system for the calibration of capsule-type standard platinum resistance thermometers at NMIJ/AIST
    Nakano, T.
    Tamura, O.
    Sakurai, H.
    [J]. INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2008, 29 (03) : 881 - 889
  • [8] Comparison System for the Calibration of Capsule-Type Standard Platinum Resistance Thermometers at NMIJ/AIST
    T. Nakano
    O. Tamura
    H. Sakurai
    [J]. International Journal of Thermophysics, 2008, 29 : 881 - 889
  • [9] Temperature-Measurement Errors with Capsule-Type Resistance Thermometers
    Gaiser, C.
    Fellmuth, B.
    [J]. TEMPERATURE: ITS MEASUREMENT AND CONTROL IN SCIENCE AND INDUSTRY, VOL 8, 2013, 1552 : 427 - 432
  • [10] Characteristics of Rhodium-Iron Resistance Thermometers and Interpolation Properties from 0.65 K To 24.5561 K
    Rusby, R. L.
    Tew, W. L.
    [J]. TEMPERATURE: ITS MEASUREMENT AND CONTROL IN SCIENCE AND INDUSTRY, VOL 8, 2013, 1552 : 409 - 413