Construction of a sensitive cascade catalytic method for measurements of plasma phosphatidylcholine

被引:0
|
作者
Zahra Karami
Marzieh Khaksar
机构
[1] Shahid Bahonar University of Kerman,Department of Biology, Faculty of Sciences
关键词
Phosphatidylcholine; Catalytic cascade; Colorimetric method; Kinetic; Sensing;
D O I
暂无
中图分类号
学科分类号
摘要
Abnormal metabolism of phosphatidylcholine (PC) leads to diseases such as cardiovascular, respiratory distress syndrome, chronic inflammatory bowel, and Alzheimer. In this study, we established an efficient colorimetric catalytic cascade system to measure PC value. In the first stage, PC is hydrolyzed to choline and phosphatidic acid by phospholipase D (PLD). Then, choline is used to produce hydrogen peroxide by choline oxidase (ChO). Finally, ABTS (2,2′-Azino-bis(3-ethylbenzthiazoline-6-sulfonic acid)) produces green color in the presence of hydrogen peroxide and deoxyribozyme (DZ). Kinetic study of DZ showed that the value of Km was 0.190 and 0.078 mM for ABTS and hydrogen peroxide, respectively. Assay optimization showed that pH 7.5 and 30 °C were the best conditions for the sensing of PC. In addition, 0.075 μM DZ, 0.16 U/mL ChO, and 12 U/mL PLD were the best concentration for PC detection. The interfering study revealed that the constituents had no apparent absorbance value. The linear regression equation for PC was identified as A = 0.0052C + 0.0233 with a correlation coefficient of 0.9923. The limit of detection of this catalytic cascade system was obtained as 0.58 μM. PC evaluation in serum samples showed that the mean percentage recovery of PC was 97.98%. Taken together, good recovery and precision of PC detection designated that this colorimetric sensing approach is applicable for PC detection in real samples.
引用
收藏
页码:2001 / 2011
页数:10
相关论文
共 50 条
  • [1] Construction of a sensitive cascade catalytic method for measurements of plasma phosphatidylcholine
    Karami, Zahra
    Khaksar, Marzieh
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2020, 17 (08) : 2001 - 2011
  • [2] Rapid, specific, and sensitive measurements of plasma sphingomyelin and phosphatidylcholine
    Hojjati, MR
    Jiang, XC
    JOURNAL OF LIPID RESEARCH, 2006, 47 (03) : 673 - 676
  • [3] Chemiluminescence is a rapid and sensitive method to assess phosphatidylcholine oxidation
    Singh, SK
    Suurkuusk, M
    Eldsater, C
    Karlsson, S
    Albertsson, AC
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1996, 142 (02) : 199 - 213
  • [4] Sensitive and Convenient Detection of microRNAs Based on Cascade Amplification by Catalytic DNAzymes
    Tian, Tian
    Xiao, Heng
    Zhang, Zhengan
    Long, Yuelin
    Peng, Shuang
    Wang, Shaoru
    Zhou, Xiang
    Liu, Songmei
    Zhou, Xin
    CHEMISTRY-A EUROPEAN JOURNAL, 2013, 19 (01) : 92 - 95
  • [5] Construction of Efficient Bienzyme Cascade Catalytic System byYolk-shellStructure
    Jiang, Jiaqi
    Yang, Hongxia
    Yan, Mengfei
    Shi, Xinyao
    Li, Jiaqi
    Jiang, Yucheng
    Gaodeng Xuexiao Huaxue Xuebao/Chemical Journal of Chinese Universities, 2024, 45 (10):
  • [6] DETERMINATION OF PHOSPHATIDYLCHOLINE HYDROPEROXIDE IN PLASMA AND SERUM BY HPLC POSTCOLUMN METHOD
    AKASAKA, K
    MORIMUNE, K
    OHRUI, H
    MEGURO, H
    OHTA, M
    BUNSEKI KAGAKU, 1993, 42 (01) : 27 - 31
  • [7] NEW SENSITIVE METHOD FOR GAIN MEASUREMENTS
    HASEGAWA, KI
    NISHINO, O
    PROCEEDINGS OF THE IEEE, 1964, 52 (01) : 74 - &
  • [8] RETARDATION METHOD FOR PLASMA MEASUREMENTS
    BAKULIN, EA
    STEPIN, EV
    SHCHERBI.VV
    SOVIET PHYSICS TECHNICAL PHYSICS-USSR, 1969, 14 (01): : 77 - &
  • [9] NEW METHOD FOR CASCADE-FREE LIFETIME MEASUREMENTS
    HARDE, H
    GUTHOHRLEIN, G
    PHYSICAL REVIEW A, 1974, 10 (05) : 1488 - 1493
  • [10] A SENSITIVE METHOD FOR DETERMINATION OF HEMOGLOBIN IN PLASMA
    VANZETTI, G
    VALENTE, D
    CLINICA CHIMICA ACTA, 1965, 11 (05) : 442 - &