18F-Fluoride PET/CT for detection of sacroiliitis in ankylosing spondylitis

被引:66
|
作者
Strobel, Klaus [1 ,2 ]
Fischer, Dorothee R. [2 ]
Tamborrini, Giorgio [3 ]
Kyburz, Diego [3 ]
Stumpe, Katrin D. M. [2 ]
Hesselmann, Rolf G. X.
Johayem, A.
von Schulthess, Gustav K. [2 ]
Michel, Beat A. [3 ]
Ciurea, Adrian [3 ]
机构
[1] Cantonal Hosp Lucerne, Luzern, Switzerland
[2] Univ Zurich Hosp, Dept Med Radiol, Div Nucl Med, CH-8091 Zurich, Switzerland
[3] Univ Zurich Hosp, Dept Rheumatol, CH-8091 Zurich, Switzerland
关键词
Fluoride PET/CT; Ankylosing spondylitis; Sacroiliac joint arthritis; Quantification; RADIOGRAPHIC PROGRESSION; ACTIVE SACROILIITIS; COMPUTED-TOMOGRAPHY; BONE METASTASES; PROSTATE-CANCER; SCINTIGRAPHY; SHORTAGE;
D O I
10.1007/s00259-010-1464-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to evaluate the performance of F-18-fluoride-PET/CT (PET/CT) for the diagnosis of sacroiliac joint (SIJ) arthritis in patients with active ankylosing spondylitis (AS). Included in the study were 15 patients with AS according to the modified New York criteria (AS group) and with active disease and 13 patients with mechanical low back pain (MLBP; control group) who were investigated with whole-body F-18-fluoride PET/CT. The ratio of the uptake in the SIJ and that in the sacrum (SIJ/S) was calculated for every joint. The mean SIJ/S ratio of 30 quantified joints in the AS group was 1.66 (range 1.10-3.07) with PET/CT, and the mean SIJ/S ratio of 26 quantified joints in the MLBP group was 1.12 (range 0.71-1.52). The area under the receiver operating characteristic curve for SIJ arthritis was 0.84. With plain radiography as a the gold standard and taking an SIJ/S ratio of > 1.3 as the threshold, the sensitivity, specificity and accuracy on a per patient basis were 80%, 77% and 79%, respectively. On a per SIJ basis, the greatest sensitivity (94%) was found in grade 3 sacroiliitis (n = 16). Our results suggest that quantitative F-18-fluoride PET/CT may play a role in the diagnosis of sacroiliitis in active AS and is an alternative to conventional bone scintigraphy in times of molybdenum shortage.
引用
收藏
页码:1760 / 1765
页数:6
相关论文
共 50 条
  • [1] 18F-FLUORIDE PET/CT FOR DETECTION OF AXIAL INVOLVEMENT IN ANKYLOSING SPONDYLITIS
    Idolazzi, L.
    Vantaggiato, E.
    Salgarello, M.
    Perandini, S.
    Fassio, A.
    Povino, M. R.
    Fracassi, E.
    Viaplana, O.
    Gatti, D.
    Rossini, M.
    Adami, S.
    [J]. ANNALS OF THE RHEUMATIC DISEASES, 2015, 74 : 1158 - 1158
  • [2] 18F-fluoride PET/CT for detection of axial involvement in ankylosing spondylitis: correlation with disease activity
    Luca Idolazzi
    Matteo Salgarello
    Davide Gatti
    Ombretta Viapiana
    Elisabetta Vantaggiato
    Angelo Fassio
    Silvano Adami
    Maurizio Rossini
    [J]. Annals of Nuclear Medicine, 2016, 30 : 430 - 434
  • [3] 18F-fluoride PET/CT for detection of axial involvement in ankylosing spondylitis: correlation with disease activity
    Idolazzi, Luca
    Salgarello, Matteo
    Gatti, Davide
    Viapiana, Ombretta
    Vantaggiato, Elisabetta
    Fassio, Angelo
    Adami, Silvano
    Rossini, Maurizio
    [J]. ANNALS OF NUCLEAR MEDICINE, 2016, 30 (06) : 430 - 434
  • [4] Erratum to: 18F-fluoride PET/CT for detection of axial involvement in ankylosing spondylitis: correlation with disease activity
    Luca Idolazzi
    Matteo Salgarello
    Davide Gatti
    Ombretta Viapiana
    Elisabetta Vantaggiato
    Angelo Fassio
    Silvano Adami
    Maurizio Rossini
    [J]. Annals of Nuclear Medicine, 2016, 30 : 511 - 511
  • [5] Assessment of malignant skeletal disease:: Initial experience with 18F-fluoride PET/CT and comparison between 18F-fluoride PET and 18F-fluoride PET/CT
    Even-Sapir, E
    Metser, U
    Flusser, G
    Zuriel, L
    Kollender, Y
    Lerman, H
    Lievshitz, G
    Ron, I
    Mishani, E
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2004, 45 (02) : 272 - 278
  • [6] 18F-fluoride PET/CT for detection of axial involvement in ankylosing spondylitis: correlation with disease activity (vol 30, pg 430, 2016)
    Idolazzi, Luca
    Salgarello, Matteo
    Gatti, Davide
    Viapiana, Ombretta
    Vantaggiato, Elisabetta
    Fassio, Angelo
    Adami, Silvano
    Rossini, Maurizio
    [J]. ANNALS OF NUCLEAR MEDICINE, 2016, 30 (07) : 511 - 511
  • [7] PERFORMANCE OF HYBRID 18F-FLUORIDE PET/MRI OF THE SACROILIAC JOINTS AND THE SPINE IN PATIENTS WITH ANKYLOSING SPONDYLITIS
    Baraliakos, X.
    Buchbender, C.
    Ostendorf, B.
    Ruhlmann, V
    Heusch, P.
    Miese, F.
    Beiderwellen, K.
    Schneider, M.
    Antoch, G.
    Braun, J.
    [J]. CLINICAL AND EXPERIMENTAL RHEUMATOLOGY, 2014, 32 (05) : 827 - 827
  • [8] 18F-Fluoride PET-CT in the detection of early bioprosthetic valve degeneration
    Cartlidge, T. R. G.
    Doris, M. K.
    Sellers, S.
    Van Beek, E. J. R.
    Virmani, R.
    Leipsic, J.
    Newby, D. E.
    Dweck, M. R.
    [J]. EUROPEAN HEART JOURNAL, 2018, 39 : 239 - 239
  • [9] Detection and global quantification of cardiovascular molecular calcification by 18F-Fluoride PET/CT
    Saboury, Babak
    Beheshti, Mohsen
    Langsteger, Werner
    Torigian, Drew
    Alavi, Abass
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [10] Altered bone metabolism of the spine in ankylosing spondylitis demonstrated by 18F-fluoride PET/CT - A novel evaluation tool in patients with relatively low modified Stoke Ankylosing Spondylitis Spine Scores
    Kim, J.
    Choi, Y.
    Lee, S.
    Joo, Y.
    Kim, T.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S108 - S109