Impact of dose reduction and iterative model reconstruction on multi-detector CT imaging of the brain in patients with suspected ischemic stroke

被引:0
|
作者
Karolin J. Paprottka
Karina Kupfer
Isabelle Riederer
Claus Zimmer
Meinrad Beer
Peter B. Noël
Thomas Baum
Jan S. Kirschke
Nico Sollmann
机构
[1] Technical University of Munich,Department of Diagnostic and Interventional Neuroradiology, School of Medicine, Klinikum rechts der Isar
[2] Technical University of Munich,TUM
[3] University Hospital Ulm,Neuroimaging Center, Klinikum rechts der Isar
[4] University of Pennsylvania,Department of Diagnostic and Interventional Radiology
[5] University of California,Department of Radiology, Perelman School of Medicine
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Non-contrast cerebral computed tomography (CT) is frequently performed as a first-line diagnostic approach in patients with suspected ischemic stroke. The purpose of this study was to evaluate the performance of hybrid and model-based iterative image reconstruction for standard-dose (SD) and low-dose (LD) non-contrast cerebral imaging by multi-detector CT (MDCT). We retrospectively analyzed 131 patients with suspected ischemic stroke (mean age: 74.2 ± 14.3 years, 67 females) who underwent initial MDCT with a SD protocol (300 mAs) as well as follow-up MDCT after a maximum of 10 days with a LD protocol (200 mAs). Ischemic demarcation was detected in 26 patients for initial and in 64 patients for follow-up imaging, with diffusion-weighted magnetic resonance imaging (MRI) confirming ischemia in all of those patients. The non-contrast cerebral MDCT images were reconstructed using hybrid (Philips “iDose4”) and model-based iterative (Philips “IMR3”) reconstruction algorithms. Two readers assessed overall image quality, anatomic detail, differentiation of gray matter (GM)/white matter (WM), and conspicuity of ischemic demarcation, if any. Quantitative assessment included signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) calculations for WM, GM, and demarcated areas. Ischemic demarcation was detected in all MDCT images of affected patients by both readers, irrespective of the reconstruction method used. For LD imaging, anatomic detail and GM/WM differentiation was significantly better when using the model-based iterative compared to the hybrid reconstruction method. Furthermore, CNR of GM/WM as well as the SNR of WM and GM of healthy brain tissue were significantly higher for LD images with model-based iterative reconstruction when compared to SD or LD images reconstructed with the hybrid algorithm. For patients with ischemic demarcation, there was a significant difference between images using hybrid versus model-based iterative reconstruction for CNR of ischemic/contralateral unaffected areas (mean ± standard deviation: SD_IMR: 4.4 ± 3.1, SD_iDose: 3.5 ± 2.3, P < 0.0001; LD_IMR: 4.6 ± 2.9, LD_iDose: 3.2 ± 2.1, P < 0.0001).  In conclusion, model-based iterative reconstruction provides higher CNR and SNR without significant loss of image quality for non-enhanced cerebral MDCT.
引用
收藏
相关论文
共 50 条
  • [1] Impact of dose reduction and iterative model reconstruction on multi-detector CT imaging of the brain in patients with suspected ischemic stroke
    Paprottka, Karolin J.
    Kupfer, Karina
    Riederer, Isabelle
    Zimmer, Claus
    Beer, Meinrad
    Noel, Peter B.
    Baum, Thomas
    Kirschke, Jan S.
    Sollmann, Nico
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [2] Dose reduction with iterative reconstruction in multi-detector CT: What is the impact on deformation of circular structures in phantom study?
    Greffier, J.
    Macri, F.
    Larbi, A.
    Fernandez, A.
    Pereira, F.
    Mekkaoui, C.
    Beregi, J. -P.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2016, 97 (02) : 187 - 196
  • [3] Diagnostic usefulness of low-dose lumbar multi-detector CT with iterative reconstruction in trauma patients: a comparison with standard-dose CT
    Lee, Sun Hwa
    Yun, Seong Jong
    Kim, Dong Hyeon
    Jo, Hyeon Hwan
    Song, Jae Gwang
    Park, Yong Sung
    BRITISH JOURNAL OF RADIOLOGY, 2017, 90 (1077):
  • [4] Utility of CT perfusion with 64-row multi-detector CT for acute ischemic brain stroke
    Suzuki K.
    Morita S.
    Masukawa A.
    Machida H.
    Ueno E.
    Emergency Radiology, 2011, 18 (2) : 95 - 101
  • [5] Model-based Iterative Reconstruction for Multi-Detector Row CT Assessment of the Adamkiewicz Artery
    Nishida, Junko
    Kitagawa, Kakuya
    Nagata, Motonori
    Yamazaki, Akio
    Nagasawa, Naoki
    Sakuma, Hajime
    RADIOLOGY, 2014, 270 (01) : 282 - 291
  • [6] Suspected acute colon diverticulitis: Imaging with low-dose unenhanced multi-detector row CT
    Tack, D
    Bohy, P
    Perlot, I
    De Maertelaer, V
    Alkeilani, O
    Sourtzis, S
    Gevenois, PA
    RADIOLOGY, 2005, 237 (01) : 189 - 196
  • [7] Diagnostic accuracy of low-dose 256-slice multi-detector coronary CT angiography using iterative reconstruction in patients with suspected coronary artery disease
    Hou, Yang
    Ma, Yue
    Fan, Weipeng
    Wang, Yuke
    Yu, Mei
    Vembar, Mani
    Guo, Qiyong
    EUROPEAN RADIOLOGY, 2014, 24 (01) : 3 - 11
  • [8] Diagnostic accuracy of low-dose 256-slice multi-detector coronary CT angiography using iterative reconstruction in patients with suspected coronary artery disease
    Yang Hou
    Yue Ma
    Weipeng Fan
    Yuke Wang
    Mei Yu
    Mani Vembar
    Qiyong Guo
    European Radiology, 2014, 24 : 3 - 11
  • [9] Evaluation of Dose Reduction and Image Quality in Pediatric Multi-detector CT
    Lee, Seung-Wan
    Kim, Hee-Joung
    Kim, Dae-Hong
    Lee, Chang-Lae
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2010, 57 (01) : 183 - 191
  • [10] Feasibility of low-dose unenhanced multi-detector CT in patients with suspected acute appendicitis: comparison with sonography
    Karabulut, Nevzat
    Kiroglu, Yilmaz
    Herek, Duygu
    Kocak, Tevfik Baris
    Erdur, Bulent
    CLINICAL IMAGING, 2014, 38 (03) : 296 - 301