Accuracy of single-energy quantitative computed tomography in the assessment of bone mineral density of cervical vertebrae

被引:0
|
作者
P.-M. Zink
M. Samii
W. Luedemann
M. Bellinzona
M. Prokop
机构
[1] Neurosurgical Clinic,
[2] Research Laboratory,undefined
[3] Nordstadt Hospital,undefined
[4] Hannover,undefined
[5] Department of Diagnostic Radiology I,undefined
[6] Hannover Medical School,undefined
[7] Hannover,undefined
来源
European Radiology | 1997年 / 7卷
关键词
Key words: Bone mineral density; Cervical vertebrae; Experimental study; Single-energy quantitative CT;
D O I
暂无
中图分类号
学科分类号
摘要
Earlier studies have shown that single-energy quantitative computed tomography (SEQCT) is a reliable method for bone mineral density (BMD) measurements in thoracic and lumbar vertebrae. Moreover, SEQCT has proved to be a useful parameter in the selection of appropriate implants in cervical spondylodesis. The aim of this study was to determine the accuracy of SEQCT in cervical vertebrae BMD measurement. BMD with reference to calcium hydroxyapatite (Ca10[PO4]6[OH]2) was assessed by SEQCT in 100 human vertebral bodies of the cervical spine. Bone cylinders were then cut from the appropriate region of interest. The cylinder volume was determined by the liquid displacement technique. The density of the mineral component was measured following incineration at 1100 °C for 24 h. The calculated BMD was correlated with the SEQCT values, resulting in a coefficient of r = 0.79 (P < 0.01). Mean SEQCT values were significantly lower than those determined by direct density assessment (t-test for coupled sampling, P < 0.02). This result was in agreement with studies on thoracic and lumbar vertebrae. These data suggest that SEQCT can reliably measure BMD in the cervical spine.
引用
收藏
页码:1436 / 1440
页数:4
相关论文
共 50 条
  • [1] Accuracy of single-energy quantitative computed tomography in the assessment of bone mineral density of cervical vertebrae
    Zink, PM
    Samii, M
    Luedemann, W
    Bellinzona, M
    Prokop, M
    [J]. EUROPEAN RADIOLOGY, 1997, 7 (09) : 1436 - 1440
  • [2] Assessment of the bone mineral density in the lumbar vertebrae of newborns by quantitative computed tomography
    Braillon, PM
    Lapillonne, A
    Ho, PS
    Bouvier, R
    Bochu, M
    Salle, BL
    [J]. SKELETAL RADIOLOGY, 1996, 25 (08) : 711 - 715
  • [3] Bone Mineral Density Measurements of Lumbar Vertebrae by Quantitative Computed Tomography
    Riaz, Hassan
    Khan, Obaid Ullah
    Akram, Hamid
    [J]. RAWAL MEDICAL JOURNAL, 2009, 34 (01): : 4 - +
  • [4] QUANTIFICATION OF BONE-MINERAL MEASURED BY SINGLE-ENERGY COMPUTED-TOMOGRAPHY
    HUSBY, T
    HOISETH, A
    HAFFNER, F
    ALHO, A
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1989, 60 (04): : 435 - 438
  • [5] BONE-MINERAL ANALYSIS USING SINGLE-ENERGY COMPUTED-TOMOGRAPHY
    ORPHANOUDAKIS, SC
    JENSEN, PS
    RAUSCHKOLB, EN
    LANG, R
    RASMUSSEN, H
    [J]. INVESTIGATIVE RADIOLOGY, 1979, 14 (02) : 122 - 130
  • [6] IMPROVED ACCURACY OF SINGLE-ENERGY COMPUTED-TOMOGRAPHY BONE-MINERAL DETERMINATION USING THRESHOLD ANALYSIS
    REINUS, WR
    NADEL, S
    [J]. INVESTIGATIVE RADIOLOGY, 1987, 22 (06) : 484 - 489
  • [7] Fractional quantitative computed tomography for bone mineral density evaluation - Accuracy, precision, and comparison to quantitative computed tomography
    Lee, J
    Shin, HI
    Kim, SY
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2004, 28 (04) : 566 - 571
  • [8] ASSESSMENT OF FELINE BONE MINERAL DENSITY: QUANTITATIVE COMPUTED TOMOGRAPHY.
    Lee, Y.
    Cheon, H.
    Lee, D.
    Yang, M. P.
    Chang, J.
    Kang, J. H.
    Chang, D.
    [J]. JOURNAL OF VETERINARY INTERNAL MEDICINE, 2011, 25 (03) : 739 - 739
  • [9] Population-Stratified Analysis of Bone Mineral Density Distribution in Cervical and Lumbar Vertebrae of Chinese from Quantitative Computed Tomography
    Zhang, Yong
    Zhou, Zhuang
    Wu, Cheng'ai
    Zhao, Danhui
    Wang, Chao
    Cheng, Xiaoguang
    Cai, Wei
    Wang, Ling
    Duanmu, Yangyang
    Zhang, Chenxin
    Tian, Wei
    [J]. KOREAN JOURNAL OF RADIOLOGY, 2016, 17 (05) : 581 - 589
  • [10] Accuracy of Quantitative Computed Tomography Bone Mineral Density Measurements in Mandibles: A Cadaveric Study
    Miguel-Sanchez, Alfonso
    Vilaplana-Vivo, Jaime
    Vilaplana-Vivo, Carlos
    Angel Vilaplana-Gomez, Juan
    Camacho-Alonso, Fabio
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 (04) : 693 - 699