Estimates of the image quality and the radiation dose for head and abdomen phantom image acquisition by using dual-energy CT

被引:0
|
作者
Dae-Hong Kim
Hee-Joung Kim
Chang-Lae Lee
Pil-Hyun Jeon
Won-Hyung Lee
Sung-Soo Jeon
机构
[1] Yonsei University,Department of Radiological Science and Institute of Health Science, College of Health Science
[2] Yonsei University Wonju Christian Hospital,Department of Radiology
来源
关键词
Linearly-mixed image; CTDIw; Contrast-to-noise ratios (CNR); Dual-energy CT;
D O I
暂无
中图分类号
学科分类号
摘要
Using dual-energy computed tomography (CT) scans, we obtained images from a raw data set by using low- and high-energy scans (usually 80 and 140 kV, respectively). Generally, the head and the abdomen examinations were performed using single-energy (120 kV) scanning with a routine exposure protocol, and the images were used for diagnostic interpretation. The dual-energy CT scans can also be used for diagnosis by using the linearly-mixed method with low- and high-energy images. In the current study, we evaluated mixed images in dual-energy and single-energy scans for image quality and radiation dose. The CT scan protocol for single energy was adopted from IEC protocols, and the recommended dose from the EC. The dual-energy scan protocol was based on the Siemens dual-energy CT scan protocol. The CT scan protocols were extended further in the mA range for both scans to estimate the image quality corresponding to these dose alternations. The results demonstrate that the Contrast-to-noise ratio (CNR) value of a dual-energy mixed image is higher than that of a single-energy image in similar dose regions for both the head and the abdomen phantoms. We observed that the dual-energy images could reduce the dose compared to single-energy images. In the abdomen phantom study, the CNR of dual-energy images was even higher than that of single-energy images with half the radiation dose of the single-energy scan. Therefore, the dual-energy CT scan can accomplish a remarkable dose reduction while preserving image quality for head and abdomen imaging.
引用
收藏
页码:1150 / 1156
页数:6
相关论文
共 50 条
  • [1] Estimates of the Image Quality and the Radiation Dose for Head and Abdomen Phantom Image Acquisition by Using Dual-energy CT
    Kim, Dae-Hong
    Kim, Hee-Joung
    Lee, Chang-Lae
    Jeon, Pil-Hyun
    Lee, Won-Hyung
    Jeon, Sung-Soo
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2012, 60 (07) : 1150 - 1156
  • [2] Dual-energy CT for routine imaging of the abdomen and pelvis: radiation dose and image quality
    Wortman, Jeremy R.
    Shyu, Jeffrey Y.
    Dileo, Jeffrey
    Uyeda, Jennifer W.
    Sodickson, Aaron D.
    [J]. EMERGENCY RADIOLOGY, 2020, 27 (01) : 45 - 50
  • [3] Dual-energy CT for routine imaging of the abdomen and pelvis: radiation dose and image quality
    Jeremy R. Wortman
    Jeffrey Y. Shyu
    Jeffrey Dileo
    Jennifer W. Uyeda
    Aaron D. Sodickson
    [J]. Emergency Radiology, 2020, 27 : 45 - 50
  • [4] Evaluation of image quality and radiation dose using gold nanoparticles and other clinical contrast agents in dual-energy Computed Tomography (CT): CT abdomen phantom
    Zukhi, J.
    Yusob, D.
    Tajuddin, A. A.
    Vuanghao, L.
    Zainon, R.
    [J]. 10TH INTERNATIONAL SEMINAR ON MEDICAL PHYSICS & 1ST AMDI INTERNATIONAL ONCOLOGY SYMPOSIUM, 2017, 851
  • [5] Image Quality and Radiation Dose of Dual-Energy CT of the Head and Neck Compared with a Standard 120-kVp Acquisition
    Tawfik, A. M.
    Kerl, J. M.
    Razek, A. A.
    Bauer, R. W.
    Nour-Eldin, N. E.
    Vogl, T. J.
    Mack, M. G.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (11) : 1994 - 1999
  • [6] Evaluation of image quality and radiation dose of abdominal dual-energy CT
    Schmidt, David
    Soderberg, Marcus
    Nilsson, Mats
    Lindvall, Hakan
    Christoffersen, Christina
    Leander, Peter
    [J]. ACTA RADIOLOGICA, 2018, 59 (07) : 845 - 852
  • [7] Deep learning image reconstruction to improve accuracy of iodine quantification and image quality in dual-energy CT of the abdomen: a phantom and clinical study
    Fukutomi, Akiyo
    Sofue, Keitaro
    Ueshima, Eisuke
    Negi, Noriyuki
    Ueno, Yoshiko
    Tsujita, Yushi
    Yabe, Shinji
    Yamaguchi, Takeru
    Shimada, Ryuji
    Kusaka, Akiko
    Hori, Masatoshi
    Murakami, Takamichi
    [J]. EUROPEAN RADIOLOGY, 2023, 33 (02) : 1388 - 1399
  • [8] Deep learning image reconstruction to improve accuracy of iodine quantification and image quality in dual-energy CT of the abdomen: a phantom and clinical study
    Akiyo Fukutomi
    Keitaro Sofue
    Eisuke Ueshima
    Noriyuki Negi
    Yoshiko Ueno
    Yushi Tsujita
    Shinji Yabe
    Takeru Yamaguchi
    Ryuji Shimada
    Akiko Kusaka
    Masatoshi Hori
    Takamichi Murakami
    [J]. European Radiology, 2023, 33 : 1388 - 1399
  • [9] Virtual monochromatic imaging in dual-source dual-energy CT: Radiation dose and image quality
    Yu, Lifeng
    Christner, Jodie A.
    Leng, Shuai
    Wang, Jia
    Fletcher, Joel G.
    McCollough, Cynthia H.
    [J]. MEDICAL PHYSICS, 2011, 38 (12) : 6371 - 6379
  • [10] Dual-Energy CT of the Abdomen and Pelvis: Radiation Dose Considerations
    Grajo, Joseph R.
    Sahani, Dushyant V.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2018, 15 (08) : 1128 - 1132