Electrophysiological evaluation of a chronically implanted electrode for suprachoroidal transretinal stimulation in rabbit eyes

被引:0
|
作者
Kentaro Nishida
Hirokazu Sakaguchi
Motohiro Kamei
Toru Saito
Takashi Fujikado
Kohji Nishida
机构
[1] Osaka University Graduate School of Medicine,Department of Ophthalmology
[2] Aichi Medical University,Department of Ophthalmology
[3] NIDEK Co.,undefined
[4] Ltd,undefined
来源
关键词
Suprachoroidal transretinal stimulation; Electrically evoked potentials; Electroretinograms; Visually evoked potentials; Resistance;
D O I
暂无
中图分类号
学科分类号
摘要
In this study, we aimed to determine the electrophysiological efficacy, safety, and electrical stability of a chronically implanted electrode for suprachoroidal transretinal stimulation (STS) in rabbit eyes. A platinum microelectrode was implanted into the scleral pocket of rabbit eyes (n = 5) and followed-up for 6 months. To evaluate the electrophysiological efficacy, electrically evoked potentials (EEPs) were measured every month after implantation. To evaluate safety, fundus examinations, fluorescein angiograms, electroretinograms (ERGs), and visually evoked potentials (VEPs) were measured before and every month after the implantation. At the end of the experiment, histological examination of retinal tissue beneath the site of the electrode was performed. To evaluate electrical stability, the resistance of the circuit was measured every month after implantation. EEPs could be elicited from the STS electrodes at all testing times. The mean threshold current to evoke EEPs was 186.4 ± 47.0 µA at 6 months after implantation. There was no significant change in the threshold over the follow-up period. The resistance of the circuit was significantly increased at 1 months after implantation, with no further increase at 6 months. There was no statistically significant change in the relative amplitudes and implicit times of a- and b-waves of ERGs and VEPs. No intraocular infection, inflammation, or vitreoretinal proliferation was observed in any eye. Histological examination revealed no retinal damage beneath the electrode. We conclude that chronically implanted electrodes for STS appear to be effective, safe, and electrically stable.
引用
收藏
页码:237 / 245
页数:8
相关论文
共 50 条
  • [1] Electrophysiological evaluation of a chronically implanted electrode for suprachoroidal transretinal stimulation in rabbit eyes
    Nishida, Kentaro
    Sakaguchi, Hirokazu
    Kamei, Motohiro
    Saito, Toru
    Fujikado, Takashi
    Nishida, Kohji
    JOURNAL OF ARTIFICIAL ORGANS, 2019, 22 (03) : 237 - 245
  • [2] Electrophysiological Evaluation of Rabbit Eyes Chronically Implanted With Electrode for Suprachoroidal Transretinal Stimulation
    Nishida, K.
    Sakaguchi, H.
    Fujikado, T.
    Kamei, M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [3] Transretinal electrical stimulation with a suprachoroidal multichannel electrode in rabbit eyes
    Sakaguchi, H
    Fujikado, T
    Fang, XY
    Kanda, H
    Osanai, M
    Nakauchi, K
    Ikuno, Y
    Kamei, M
    Yagi, T
    Nishimura, S
    Ohji, M
    Yagi, T
    Tano, Y
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2004, 48 (03) : 256 - 261
  • [4] Transretinal Electrical Stimulation with a Suprachoroidal Multichannel Electrode in Rabbit Eyes
    Hirokazu Sakaguchi
    Takashi Fujikado
    Xiaoyun Fang
    Hiroyuki Kanda
    Makoto Osanai
    Kazuaki Nakauchi
    Yasushi Ikuno
    Motohiro Kamei
    Tohru Yagi
    Shigeru Nishimura
    Masahito Ohji
    Tetsuya Yagi
    Yasuo Tano
    Japanese Journal of Ophthalmology, 2004, 48 : 256 - 261
  • [5] Transretinal electrical stimulation with a suprachoroidal multichannel electrode in rabbit eyes
    Sakaguchi, H
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2004, 48 (05) : 515 - 515
  • [6] Erratum to: Transretinal Electrical Stimulation with a Suprachoroidal Multichannel Electrode in Rabbit Eyes
    Hirokazu Sakaguchi
    Takashi Fujikado
    Xiaoyun Fang
    Hiroyuki Kanda
    Makoto Osanai
    Kazuaki Nakauchi
    Yasushi Ikuno
    Motohiro Kamei
    Tohru Yagi
    Shigeru Nishimura
    Masahito Ohji
    Tetsuya Yagi
    Yasuo Tano
    Japanese Journal of Ophthalmology, 2004, 48 : 515 - 515
  • [7] Safety and effectiveness of suprachoroidal-transretinal stimulation by chronically implanted electrode with continuous electrical stimulation in rabbits
    Nakauchi, K
    Fujikado, T
    Ohta, J
    Tokuda, T
    Kanda, H
    Terasawa, Y
    Ozawa, M
    Hirakata, A
    Tano, Y
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [8] Transretinal electrical stimulation by intrascleral multichannel electrode in rabbit eyes
    Nakauchi, K
    Fujikado, T
    Kanda, H
    Ikuno, Y
    Sakaguchi, H
    Kamei, M
    Ohji, M
    Yagi, T
    Nishimura, S
    Tano, Y
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U703 - U703
  • [9] Transretinal electrical stimulation by an intrascleral multichannel electrode array in rabbit eyes
    Kazuaki Nakauchi
    Takashi Fujikado
    Hiroyuki Kanda
    Takeshi Morimoto
    Jun S. Choi
    Yasushi Ikuno
    Hirokazu Sakaguchi
    Motohiro Kamei
    Masahito Ohji
    Tohru Yagi
    Shigeru Nishimura
    Hajime Sawai
    Yutaka Fukuda
    Yasuo Tano
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2005, 243 : 169 - 174
  • [10] Transretinal electrical stimulation by an intrascleral multichannel electrode array in rabbit eyes
    Nakauchi, K
    Fujikado, T
    Kanda, H
    Morimoto, T
    Choi, JS
    Ikuno, Y
    Sakaguchi, H
    Kamei, M
    Ohji, M
    Yagi, T
    Nishimura, S
    Sawai, H
    Fukuda, Y
    Tano, Y
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2005, 243 (02) : 169 - 174