Experimental investigation of microstructural changes in soils eroded by suffusion using X-ray tomography

被引:0
|
作者
Cong Doan Nguyen
Nadia Benahmed
Edward Andò
Luc Sibille
Pierre Philippe
机构
[1] Irstea,
[2] Aix Marseille Univ,undefined
[3] RECOVER,undefined
[4] University Grenoble Alpes,undefined
[5] CNRS,undefined
[6] Grenoble INP,undefined
[7] 3SR,undefined
来源
Acta Geotechnica | 2019年 / 14卷
关键词
Heterogeneity; Internal erosion; Microstructure; Suffusion; X-ray computed tomography;
D O I
暂无
中图分类号
学科分类号
摘要
Internal erosion is a complex phenomenon which represents one of the main risks to the safety of earthen hydraulic structures such as embankment dams, dikes or levees. Its occurrence may cause instability and failure of these structures with consequences that can be dramatic. The specific mode of erosion by suffusion is the one characterized by seepage flow-induced erosion, and the subsequent migration of the finest soil particles through the surrounding soil matrix mostly constituted of large grains. Such a phenomenon can lead to a modification of the initial microstructure and, hence, to a change in the physical, hydraulic and mechanical properties of the soil. A direct comparison of the mechanical behaviour of soil before and after erosion is often used to investigate the impact of internal erosion on soil strength (shear strength at peak and critical state) using triaxial tests. However, the obtained results are somehow contradictory, as for instance in Chang’s study (Chang and Zhang in Geotech Test J 34(6):579–589, 2011), where it is concluded that the drained strength of eroded soil decreases compared to non-eroded soil, while both Xiao and Shwiyhat (Geotech Test J 35(6):890–900, 2012) and Ke and Takahashi (Geotech Test J 37(2):347–364, 2014) have come to the opposite conclusion. A plausible explanation of these contradictions might be attributed to the rather heterogeneous nature of the suffusion process and to the way the coarse and fine grains are rearranged afterwards leading to a heterogeneous soil structure, a point that, for now, is not taken into account, nor even mentioned, in the existing analyses. In the present study, X-ray computed tomography (X-ray CT) is used to follow the microstructure evolution of a granular soil during a suffusion test, and, therefore, to capture the induced microstructural changes. The images obtained from X-ray CT reveal indeed that fine particles erosion is obviously not homogeneous, highlighting the existence of preferential flow paths that lead to a heterogeneous sample in terms of fine particles, void ratio and inter-granular void ratio distribution.
引用
收藏
页码:749 / 765
页数:16
相关论文
共 50 条
  • [1] Experimental investigation of microstructural changes in soils eroded by suffusion using X-ray tomography
    Cong Doan Nguyen
    Benahmed, Nadia
    Ando, Edward
    Sibille, Luc
    Philippe, Pierre
    ACTA GEOTECHNICA, 2019, 14 (03) : 749 - 765
  • [2] X-RAY TOMOGRAPHY FOR MICROSTRUCTURAL OBJECTS
    SATO, T
    IKEDA, O
    YAMAKOSHI, Y
    TSUBOUCHI, M
    APPLIED OPTICS, 1981, 20 (22): : 3880 - 3883
  • [3] Experimental investigation of void coalescence in a dual phase steel using X-ray tomography
    Landron, C.
    Bouaziz, O.
    Maire, E.
    Adrien, J.
    ACTA MATERIALIA, 2013, 61 (18) : 6821 - 6829
  • [4] Fluidization of spherical versus elongated particles - experimental investigation using X-ray tomography
    Mema, Ivan
    Wagner, Evert C.
    van Ommen, J. Ruud
    Padding, Johan T.
    CHEMICAL ENGINEERING JOURNAL, 2020, 397
  • [5] Experimental Investigation of Cavitation-Induced Erosion Using X-Ray Imaging and Tomography
    Moon, Chi Young
    Magnotti, Gina M.
    Sforzo, Brandon A.
    Tekawade, Aniket
    Kastengren, Alan L.
    Powell, Christopher F.
    FRONTIERS IN MECHANICAL ENGINEERING-SWITZERLAND, 2022, 8
  • [6] Experimental investigation of junction growth of rough contacts using X-ray computed tomography
    Wang, Runliang
    Liu, Jianhua
    Liu, Bo
    Jia, Duo
    Ding, Xiaoyu
    FRICTION, 2024, 12 (11) : 2519 - 2531
  • [7] Investigation of the microstructural characteristics and the tensile strength of silkworm cocoons using X-ray micro computed tomography
    Song, Wenfang
    Zhang, Chengjiao
    Wang, Zhaoli
    MATERIALS & DESIGN, 2021, 199
  • [8] X-RAY DETERMINATION OF MICROSTRUCTURAL PARAMETERS OF ERODED CU-AL ALLOYS
    BHIKSHAMAIAH, G
    SURYANARAYANA, SV
    NAIDU, SVN
    RAJASHEKARAN, T
    GOPALAN, R
    WEAR, 1988, 125 (03) : 241 - 256
  • [9] Laboratory X-ray Tomography: A Valuable Experimental Tool for Revealing Processes in Soils
    Viggiani, G.
    Ando, E.
    Takano, D.
    Santamarina, J. C.
    GEOTECHNICAL TESTING JOURNAL, 2015, 38 (01): : 61 - 71
  • [10] Microstructural investigation of concretes with recycled aggregates using X-ray microtomography
    de Almeida Ferreira, Isabel Christina
    Paciornik, Sidnei
    de Andrade Silva, Flavio
    JOURNAL OF BUILDING ENGINEERING, 2024, 84