Towards analytically useful two-dimensional Fourier transform ion cyclotron resonance mass spectrometry

被引:0
|
作者
Maria A. van Agthoven
Marc-André Delsuc
Geoffrey Bodenhausen
Christian Rolando
机构
[1] Miniaturisation pour la Synthèse l’Analyse et la Protéomique,U 596 and UMR CNRS 7104, Institut de Génétique et de Biologie Moléculaire et Cellulaire, INSERM
[2] USR CNRS 3290,UMR 7203, Département de Chimie
[3] Institut Michel-Eugène Chevreul,undefined
[4] FR CNRS 2638 and Protéomique,undefined
[5] Modifications Post-Traductionnelles et Glycobiologie,undefined
[6] IFR 147 Université de Lille 1,undefined
[7] Sciences et Technologie,undefined
[8] Université de Strasbourg,undefined
[9] École Normale Supérieure,undefined
来源
关键词
Mass spectrometry; Fourier transform ion cyclotron resonance; Two-dimensional; FT-ICR;
D O I
暂无
中图分类号
学科分类号
摘要
Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry (MS) achieves high resolution and mass accuracy, allowing the identification of the raw chemical formulae of ions in complex samples. Using ion isolation and fragmentation (MS/MS), we can obtain more structural information, but MS/MS is time- and sample-consuming because each ion must be isolated before fragmentation. In 1987, Pfändler et al. proposed an experiment for 2D FT-ICR MS in order to fragment ions without isolating them and to visualize the fragmentations of complex samples in a single 2D mass spectrum, like 2D NMR spectroscopy. Because of limitations of electronics and computers, few studies have been conducted with this technique. The improvement of modern computers and the use of digital electronics for FT-ICR hardware now make it possible to acquire 2D mass spectra over a broad mass range. The original experiments used in-cell collision-induced dissociation, which caused a loss of resolution. Gas-free fragmentation modes such as infrared multiphoton dissociation and electron capture dissociation allow one to measure high-resolution 2D mass spectra. Consequently, there is renewed interest to develop 2D FT-ICR MS into an efficient analytical method. Improvements introduced in 2D NMR spectroscopy can also be transposed to 2D FT-ICR MS. We describe the history of 2D FT-ICR MS, introduce recent improvements, and present analytical applications to map the fragmentation of peptides. Finally, we provide a glossary which defines a few keywords for the 2D FT-ICR MS field.
引用
收藏
页码:51 / 61
页数:10
相关论文
共 50 条
  • [1] Towards analytically useful two-dimensional Fourier transform ion cyclotron resonance mass spectrometry
    van Agthoven, Maria A.
    Delsuc, Marc-Andre
    Bodenhausen, Geoffrey
    Rolando, Christian
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (01) : 51 - 61
  • [2] TWO-DIMENSIONAL FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY
    PFANDLER, P
    BODENHAUSEN, G
    RAPIN, J
    HOURIET, R
    GAUMANN, T
    CHEMICAL PHYSICS LETTERS, 1987, 138 (2-3) : 195 - 200
  • [3] Two-Dimensional Fourier Transform Ion Cyclotron Resonance Mass Spectrometry of N-Linked Glycopeptides
    Bell, Richard J.
    Hage, David S.
    Dodds, Eric D.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2024, 35 (06) : 1208 - 1216
  • [4] A THEORY FOR TWO-DIMENSIONAL FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY
    GUAN, SH
    JONES, PR
    JOURNAL OF CHEMICAL PHYSICS, 1989, 91 (09): : 5291 - 5295
  • [5] Differentiating Fragmentation Pathways of Cholesterol by Two-Dimensional Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
    van Agthoven, Maria A.
    Barrow, Mark P.
    Chiron, Lionel
    Coutouly, Marie-Aude
    Kilgour, David
    Wootton, Christopher A.
    Wei, Juan
    Soulby, Andrew
    Delsuc, Marc-Andre
    Rolando, Christian
    O'Connor, Peter B.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2015, 26 (12) : 2105 - 2114
  • [6] Fourier transform ion cyclotron resonance mass spectrometry
    Marshall, AG
    FOURIER TRANSFORM SPECTROSCOPY, 1998, (430): : 3 - 13
  • [7] Two-Dimensional Fourier Transform Ion Cyclotron Resonance Mass Spectrometry by Matrix-Assisted Laser Desorption Ionization
    Bell, Richard J.
    Hage, David S.
    Dodds, Eric D.
    ANALYTICAL CHEMISTRY, 2024, 96 (17) : 6584 - 6587
  • [8] Fourier Transform Ion Cyclotron Resonance Mass Spectrometry at the Cyclotron Frequency
    Nagornov, Konstantin O.
    Kozhinov, Anton N.
    Tsybin, Yury O.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2017, 28 (04) : 768 - 780
  • [9] Fourier transform ion cyclotron resonance mass spectrometry: A primer
    Marshall, AG
    Hendrickson, CL
    Jackson, GS
    MASS SPECTROMETRY REVIEWS, 1998, 17 (01) : 1 - 35
  • [10] Fourier transform ion cyclotron resonance mass spectrometry - Preface
    Marshall, AG