The possibilities and limitations of the numerous individual methods used for boron analysis for BNCT in clinical and biological samples are reported in detail. The main interferences of the analytical methods are described. Sample pretreatment techniques are discussed. The methods reviewed for boron analysis for BNCT concern atomic spectrometry, radioanalytical methods, and imaging techniques. An error analysis of boron determinations in biomaterials is performed and typical boron distribution patterns in small mammalians are discussed.
引用
收藏
页码:391 / 403
页数:12
相关论文
共 50 条
  • [1] Methods for boron analysis in boron neutron capture therapy (BNCT). A review
    Probst, TU
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 364 (05): : 391 - 403
  • [2] The Development of Boron Analysis and Imaging in Boron Neutron Capture Therapy (BNCT)
    Dai, Qi
    Yang, QiYao
    Bao, Xiaoyan
    Chen, Jiejian
    Han, Min
    Wei, Qichun
    MOLECULAR PHARMACEUTICS, 2022, 19 (02) : 363 - 377
  • [3] Boron analysis and boron imaging in biological materials for Boron Neutron Capture Therapy (BNCT)
    Wittig, Andrea
    Michel, Jean
    Moss, Raymond L.
    Stecher-Rasmussen, Finn
    Arlinghaus, Heinrich F.
    Bendel, Peter
    Mauri, Pier Luigi
    Altieri, Saverio
    Hilger, Ralf
    Salvadori, Piero A.
    Menichetti, Luca
    Zamenhof, Robert
    Sauerwein, Wolfgang A. G.
    CRITICAL REVIEWS IN ONCOLOGY HEMATOLOGY, 2008, 68 (01) : 66 - 90
  • [4] RENAISSANCE OF THE BORON NEUTRON CAPTURE THERAPY, BNCT
    Gryzinski, M. A.
    Maciak, M.
    Wielgosz, M.
    RAD 2015: THE THIRD INTERNATIONAL CONFERENCE ON RADIATION AND APPLICATIONS IN VARIOUS FIELDS OF RESEARCH, 2015, : 79 - 81
  • [5] Spectromicroscopy of boron for the optimization of boron neutron capture therapy (BNCT) for cancer
    Gilbert, B
    Redondo, J
    Baudat, PA
    Lorusso, GF
    Andres, R
    Van Meir, EG
    Brunet, JF
    Hamou, MF
    Suda, T
    Mercanti, D
    Ciotti, MT
    Droubay, TC
    Tonner, BP
    Perfetti, P
    Margaritondo, M
    De Stasio, G
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1998, 31 (19) : 2642 - 2647
  • [6] Critical review, with an optimistic outlook, on Boron Neutron Capture Therapy (BNCT)
    Moss, Raymond L.
    APPLIED RADIATION AND ISOTOPES, 2014, 88 : 2 - 11
  • [7] Boron neutron capture therapy (BNCT):: Implications of neutron beam and boron compound characteristics
    Wheeler, FJ
    Nigg, DW
    Capala, J
    Watkins, PRD
    Vroegindeweij, C
    Auterinen, I
    Seppälä, T
    Bleuel, D
    MEDICAL PHYSICS, 1999, 26 (07) : 1237 - 1244
  • [8] Potential of boron neutron capture therapy (BNCT) for myxofibrosarcoma
    Fujimoto, Takuya
    Andoh, Tooru
    Sudo, Tamotsu
    Fujita, Ikuo
    Sakurai, Yoshinori
    Takata, Takushi
    Tanaka, Hiroki
    Kawamoto, Teruya
    Yahiro, Shunsuke
    Nakamura, Shotaro
    Hara, Hitomi
    Fukase, Naomasa
    Akisue, Toshihiro
    Ichikawa, Hideki
    Kuroda, Ryosuke
    Suzuki, Minoru
    APPLIED RADIATION AND ISOTOPES, 2025, 217
  • [9] The Finnish boron neutron capture therapy (BNCT) project
    Auterinen, I
    15TH EUROPEAN TRIGA CONFERENCE, 1999, 197 : 121 - 131
  • [10] Boron neutron capture therapy (BNCT) - radiotherapy of the future?
    Sauerwein, W.
    Matsumura, A.
    Moss, R.
    Busse, P.
    Wittig, A.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2007, 183 : 43 - 43