Indoor air quality in urban and rural kindergartens: short-term studies in Silesia, Poland

被引:0
|
作者
Ewa Błaszczyk
Wioletta Rogula-Kozłowska
Krzysztof Klejnowski
Piotr Kubiesa
Izabela Fulara
Danuta Mielżyńska-Švach
机构
[1] Institute for Ecology of Industrial Areas,Environmental Toxicology Group
[2] Polish Academy of Science,Department of Air Protection, Institute of Environmental Engineering
[3] Institute for Ecology of Industrial Areas,Central Laboratory
[4] Witold Pilecki State School of Higher Education,Nursing Institute
来源
关键词
Indoor air quality; Kindergarten; PM2.5; PAHs; assay; Indoor/outdoor ratio;
D O I
暂无
中图分类号
学科分类号
摘要
More than 80% of people living in urban areas who monitor air pollution are exposed to air quality levels that exceed limits defined by the World Health Organization (WHO). Although all regions of the world are affected, populations in low-income cities are the most impacted. According to average annual levels of fine particulate matter (PM2.5, ambient particles with aerodynamic diameter of 2.5 μm or less) presented in the urban air quality database issued by WHO in 2016, as many as 33 Polish cities are among the 50 most polluted cities in the European Union (EU), with Silesian cities topping the list. The aim of this study was to characterize the indoor air quality in Silesian kindergartens based on the concentrations of gaseous compounds (SO2, NO2), PM2.5, and the sum of 15 PM2.5-bound polycyclic aromatic hydrocarbons (PAHs), including PM2.5-bound benzo(a)pyrene (BaP), as well as the mutagenic activity of PM2.5 organic extracts in Salmonella assay (strains: TA98, YG1024). The assessment of the indoor air quality was performed taking into consideration the pollution of the atmospheric air (outdoor). I/O ratios (indoor/outdoor concentration) for each investigated parameter were also calculated. Twenty-four-hour samples of PM2.5, SO2, and NO2 were collected during spring in two sites in southern Poland (Silesia), representing urban and rural areas. Indoor samples were taken in naturally ventilated kindergartens. At the same time, in the vicinity of the kindergarten buildings, the collection of outdoor samples of PM2.5, SO2, and NO2 was carried out. The content of BaP and the sum of 15 studied PAHs was determined in each 24-h sample of PM2.5 (indoor and outdoor). In the urban site, statistically lower concentrations of SO2 and NO2 were detected indoors compared to outdoors, whereas in the rural site, such a relationship was observed only for NO2. No statistically significant differences in the concentrations of PM2.5, PM2.5-bound BaP, and Σ15 PAHs in kindergartens (indoor) versus atmospheric (outdoor) air in the two studied areas were identified. Mutagenic effect of indoor PM2.5 samples was twice as low as in outdoor samples. The I/O ratios indicated that all studied air pollutants in the urban kindergarten originated from the ambient air. In the rural site concentrations of SO2, PM2.5 and BaP in the kindergarten were influenced by internal sources (gas and coal stoves).
引用
收藏
页码:1207 / 1220
页数:13
相关论文
共 50 条
  • [1] Indoor air quality in urban and rural kindergartens: short-term studies in Silesia, Poland
    Blaszczyk, Ewa
    Rogula-Kozlowska, Wioletta
    Klejnowski, Krzysztof
    Kubiesa, Piotr
    Fulara, Izabela
    Mielzynska-Svach, Danuta
    AIR QUALITY ATMOSPHERE AND HEALTH, 2017, 10 (10): : 1207 - 1220
  • [2] Indoor Air Quality in Kindergartens in Poland
    Zender-Swiercz, Ewa
    Telejko, Marek
    3RD WORLD MULTIDISCIPLINARY CIVIL ENGINEERING, ARCHITECTURE, URBAN PLANNING SYMPOSIUM (WMCAUS 2018), 2019, 471
  • [3] Indoor Air Quality in Urban and Rural Preschools in Upper Silesia, Poland: Particulate Matter and Carbon Dioxide
    Mainka, Anna
    Zajusz-Zubek, Elwira
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2015, 12 (07) : 7697 - 7711
  • [4] Indoor air quality in residential buildings in Upper Silesia, Poland
    Kozielska, Barbara
    Mainka, Anna
    Zak, Magdalena
    Kaleta, Dorota
    Mucha, Walter
    BUILDING AND ENVIRONMENT, 2020, 177
  • [5] Attempt to Improve Indoor Air Quality in Kindergartens
    Telejko, Marek
    Zender-Swiercz, Ewa
    WORLD MULTIDISCIPLINARY CIVIL ENGINEERING-ARCHITECTURE-URBAN PLANNING SYMPOSIUM 2016, WMCAUS 2016, 2016, 161 : 1704 - 1709
  • [6] Indoor air quality in timber built kindergartens
    Ostendorp, G.
    Heinzow, B.
    GEFAHRSTOFFE REINHALTUNG DER LUFT, 2015, 75 (03): : 71 - 75
  • [7] INVESTIGATION OF INDOOR AIR QUALITY OF KINDERGARTENS IN NANJING
    Shen, X. Y.
    Xie, X. J.
    Huang, H.
    7TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, PROCEEDINGS OF ISHVAC 2011, VOLS I-IV, 2011, : 428 - 434
  • [8] RADON MONITORING FOR SHORT-TERM EXPOSURES IN INDOOR AIR
    OPPON, OC
    AZIMIGARAKANI, D
    TOMMASINO, L
    TORRI, G
    AZIZ, S
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1988, 15 (1-4): : 633 - 636
  • [9] Consequences of energy renovation on indoor air quality in kindergartens
    Mateja Dovjak
    Jan Slobodnik
    Aleš Krainer
    Building Simulation, 2020, 13 : 691 - 708
  • [10] Microbiological and chemical quality of indoor air in kindergartens in Slovenia
    Rejc, Tanja
    Kukec, Andreja
    Bizjak, Mirko
    GodicTorkar, Karmen
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL HEALTH RESEARCH, 2020, 30 (01) : 49 - 62