The energy balance experiment EBEX-2000. Part II: Intercomparison of eddy-covariance sensors and post-field data processing methods

被引:0
|
作者
Matthias Mauder
Steven P. Oncley
Roland Vogt
Tamas Weidinger
Luis Ribeiro
Christian Bernhofer
Thomas Foken
Wim Kohsiek
Henk A. R. De Bruin
Heping Liu
机构
[1] University of Bayreuth,Department of Micrometeorology
[2] Agriculture and Agri-Food Canada,undefined
[3] National Center for Atmospheric Research Boulder,undefined
[4] University of Basel,undefined
[5] Eötvös Loránd University,undefined
[6] Bragança Polytechnic Institute,undefined
[7] Dresden University of Technology,undefined
[8] University of Bayreuth,undefined
[9] KNMI Royal Dutch Meteorological Institute,undefined
[10] Wageningen University,undefined
[11] City University of Hong Kong,undefined
[12] Jackson State University,undefined
来源
Boundary-Layer Meteorology | 2007年 / 123卷
关键词
EBEX-2000; Eddy covariance; Energy balance closure; Quality control; Sensor intercomparison; Turbulent fluxes;
D O I
暂无
中图分类号
学科分类号
摘要
The eddy-covariance method is the primary way of measuring turbulent fluxes directly. Many investigators have found that these flux measurements often do not satisfy a fundamental criterion—closure of the surface energy balance. This study investigates to what extent the eddy-covariance measurement technology can be made responsible for this deficiency, in particular the effects of instrumentation or of the post-field data processing. Therefore, current eddy-covariance sensors and several post-field data processing methods were compared. The differences in methodology resulted in deviations of 10% for the sensible heat flux and of 15% for the latent heat flux for an averaging time of 30 min. These disparities were mostly due to different sensor separation corrections and a linear detrending of the data. The impact of different instrumentation on the resulting heat flux estimates was significantly higher. Large deviations from the reference system of up to 50% were found for some sensor combinations. However, very good measurement quality was found for a CSAT3 sonic together with a KH20 krypton hygrometer and also for a UW sonic together with a KH20. If these systems are well calibrated and maintained, an accuracy of better than 5% can be achieved for 30-min values of sensible and latent heat flux measurements. The results from the sonic anemometers Gill Solent-HS, ATI-K, Metek USA-1, and R.M. Young 81000 showed more or less larger deviations from the reference system. The LI-COR LI-7500 open-path H2O/CO2 gas analyser in the test was one of the first serial numbers of this sensor type and had technical problems regarding direct solar radiation sensitivity and signal delay. These problems are known by the manufacturer and improvements of the sensor have since been made.
引用
收藏
页码:29 / 54
页数:25
相关论文
共 7 条
  • [1] The energy balance experiment EBEX-2000. Part II: Intercomparison of eddy-covariance sensors and post-field data processing methods
    Mauder, Matthias
    Oncley, Steven P.
    Vogt, Roland
    Weidinger, Tamas
    Ribeiro, Luis
    Bernhofer, Christian
    Foken, Thomas
    Kohsiek, Wim
    De Bruin, Henk A. R.
    Liu, Heping
    [J]. BOUNDARY-LAYER METEOROLOGY, 2007, 123 (01) : 29 - 54
  • [2] The Energy Balance Experiment EBEX-2000. Part I: overview and energy balance
    Steven P. Oncley
    Thomas Foken
    Roland Vogt
    Wim Kohsiek
    H. A. R. DeBruin
    Christian Bernhofer
    Andreas Christen
    Eva van Gorsel
    David Grantz
    Christian Feigenwinter
    Irene Lehner
    Claudia Liebethal
    Heping Liu
    Matthias Mauder
    Andrea Pitacco
    Luis Ribeiro
    Tamas Weidinger
    [J]. Boundary-Layer Meteorology, 2007, 123 : 1 - 28
  • [3] The Energy Balance Experiment EBEX-2000. Part I: Overview and energy balance
    Oncley, Steven P.
    Foken, Thomas
    Vogt, Roland
    Kohsiek, Wim
    DeBruin, H. A. R.
    Bernhofer, Christian
    Christen, Andreas
    van Gorsel, Eva
    Grantz, David
    Feigenwinter, Christian
    Lehner, Irene
    Liebethal, Claudia
    Liu, Heping
    Mauder, Matthias
    Pitacco, Andrea
    Ribeiro, Luis
    Weidinger, Tamas
    [J]. BOUNDARY-LAYER METEOROLOGY, 2007, 123 (01) : 1 - 28
  • [4] Impact of post-field data processing on eddy covariance flux estimates and energy balance closure
    Mauder, Matthias
    Foken, Thomas
    [J]. METEOROLOGISCHE ZEITSCHRIFT, 2006, 15 (06) : 597 - 609
  • [5] The energy balance experiment EBEX-2000. Part III: Behaviour and quality of the radiation measurements
    Kohsiek, W.
    Liebethal, C.
    Foken, T.
    Vogt, R.
    Oncley, S. P.
    Bernhofer, Ch.
    Debruin, H. A. R.
    [J]. BOUNDARY-LAYER METEOROLOGY, 2007, 123 (01) : 55 - 75
  • [6] The Energy Balance Experiment EBEX-2000. Part III: Behaviour and quality of the radiation measurements
    W. Kohsiek
    C. Liebethal
    T. Foken
    R. Vogt
    S. P. Oncley
    Ch. Bernhofer
    H. A. R. Debruin
    [J]. Boundary-Layer Meteorology, 2007, 123 : 55 - 75
  • [7] Urban Energy Balance Obtained from the Comprehensive Outdoor Scale Model Experiment. Part II: Comparisons with Field Data Using an Improved Energy Partition
    Kawai, Toru
    Kanda, Manabu
    [J]. JOURNAL OF APPLIED METEOROLOGY AND CLIMATOLOGY, 2010, 49 (07) : 1360 - 1376