Evaluation of a New Fully Automated Assay for Plasma Intact FGF23

被引:0
|
作者
Jean-Claude Souberbielle
Dominique Prié
Marie-Liesse Piketty
Anya Rothenbuhler
Pierre Delanaye
Philippe Chanson
Etienne Cavalier
机构
[1] G.H. Necker Enfants Malades,Service des Explorations Fonctionnelles
[2] Hôpital Bicêtre,Service d’Endocrinologie pédiatrique, French Reference Center for Rare Disorders of the Mineral Metabolism, Department of Endocrinology and Diabetology for Children
[3] Assistance Publique-Hôpitaux de Paris,Department of Nephrology
[4] University of Liège,Dialysis
[5] Assistance Publique-Hôpitaux de Paris,Transplantation
[6] Hôpitaux Universitaires Paris-Sud,Service d’Endocrinologie et des Maladies de la Reproduction
[7] Hôpital de Bicêtre,INSERM 1185, Fac Med Paris Sud
[8] Univ Paris-Sud,Department of Clinical Chemistry
[9] Université Paris-Saclay,undefined
[10] University of Liège,undefined
来源
关键词
FGF23; Reference values; Vitamin D; Chronic kidney disease; Hypophosphatemia; Hyperphosphatemia;
D O I
暂无
中图分类号
学科分类号
摘要
Several FGF23 immunoassays are available. However, they are reserved for research purposes as none have been approved for clinical use. We evaluated the performances of a new automated assay for intact FGF23 on the DiaSorin Liaison platform which is approved for clinical use. We established reference values in 908 healthy French subjects aged 18–89 years, and measured iFGF23 in patients with disorders of phosphate metabolism and in patients with chronic kidney disease (CKD). Intra-assay CV was 1.04–2.86% and inter-assay CV was 4.01–6.3%. The limit of quantification was <10 ng/L. Serum iFGF23 concentrations were considerably lower than EDTA values highlighting the importance of using exclusively EDTA plasma. Liaison iFGF23 values were approximately 25% higher than Immutopics values. In the 908 healthy subjects, distribution of the Liaison iFGF23 values was Gaussian with a mean ± 2SD interval of 22.7–93.1 ng/L. Men had a slightly higher level than women (60.3 ± 17.6 and 55.2 ± 17.2 ng/L, respectively). Plasma iFGF23 concentration in 11 patients with tumour-induced osteomalacia, 8 patients with X-linked hypophosphatemic rickets, 43 stage 3a, 43 stage 3b, 43 stage 4, 44 stage 5 CKD patients, and 44 dialysis patients were 217.2 ± 144.0, 150.9 ± 28.6, 98.5 ± 42.0, 130.8 ± 88.6, 130.8 ± 88.6, 331.7 ± 468.2, 788.8 ± 1306.6 and 6103.9 ± 11,178.8 ng/L, respectively. This new iFGF23 assay available on a platform that already allows the measurement of other important parameters of the mineral metabolism is a real improvement for the laboratories and clinicians/researchers involved in this field.
引用
收藏
页码:510 / 518
页数:8
相关论文
共 50 条
  • [1] Evaluation of a New Fully Automated Assay for Plasma Intact FGF23
    Souberbielle, Jean-Claude
    Prie, Dominique
    Piketty, Marie-Liesse
    Rothenbuhler, Anya
    Delanaye, Pierre
    Chanson, Philippe
    Cavalier, Etienne
    CALCIFIED TISSUE INTERNATIONAL, 2017, 101 (05) : 510 - 518
  • [2] Performance evaluation of the new chemiluminescent intact FGF23 assay relative to the existing assay system
    Hajime Kato
    Naoko Hidaka
    Minae Koga
    Noriyuki Ogawa
    Shichihiro Takahashi
    Hiromi Miyazaki
    Masaomi Nangaku
    Noriko Makita
    Nobuaki Ito
    Journal of Bone and Mineral Metabolism, 2022, 40 : 101 - 108
  • [3] Performance evaluation of the new chemiluminescent intact FGF23 assay relative to the existing assay system
    Kato, Hajime
    Hidaka, Naoko
    Koga, Minae
    Ogawa, Noriyuki
    Takahashi, Shichihiro
    Miyazaki, Hiromi
    Nangaku, Masaomi
    Makita, Noriko
    Ito, Nobuaki
    JOURNAL OF BONE AND MINERAL METABOLISM, 2022, 40 (01) : 101 - 108
  • [4] EVALUATION OF A NEW AUTOMATED CHEMILUMINESCENCE IMMUNOASSAY FOR FGF23
    Shimizu, Y.
    Fukumoto, S.
    Fujita, T.
    OSTEOPOROSIS INTERNATIONAL, 2011, 22 : S580 - S580
  • [5] Evaluation of a new automated chemiluminescence immunoassay for FGF23
    Yuichiro Shimizu
    Seiji Fukumoto
    Toshiro Fujita
    Journal of Bone and Mineral Metabolism, 2012, 30 : 217 - 221
  • [6] Evaluation of a new automated chemiluminescence immunoassay for FGF23
    Shimizu, Yuichiro
    Fukumoto, Seiji
    Fujita, Toshiro
    JOURNAL OF BONE AND MINERAL METABOLISM, 2012, 30 (02) : 217 - 221
  • [7] Technical and diagnostic performance of a new fully automated immunoassay for the determination of intact fibroblast growth factor 23 (FGF23)
    van Helden, Josef
    Weiskirchen, Ralf
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2018, 78 (7-8): : 584 - 590
  • [8] CTERMINAL FGF23 VERSUS INTACT FGF23 AS CARDIOVASCULAR PREDICTOR IN CHRONIC KIDNEY DISEASE
    Schauerte, Johanna
    Emrich, Insa
    Seiler-Mussler, Sarah
    Fliser, Danilo
    Heine, Gunnar
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2017, 32 : 68 - +
  • [9] Biological Variability of Plasma Intact and C-Terminal FGF23 Measurements
    Smith, Edward R.
    Cai, Michael M.
    McMahon, Lawrence P.
    Holt, Stephen G.
    JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2012, 97 (09): : 3357 - 3365
  • [10] Plasma FGF23 is not elevated in prostate cancer
    Vlot, Mariska C.
    Bijnsdorp, Irene
    den Heijer, Martin
    de Jonge, Robert
    van Moorselaar, R. Jeroen A.
    Heijboer, Annemieke C.
    CLINICA CHIMICA ACTA, 2018, 478 : 129 - 131