VADER: a variable dose-rate external 137Cs irradiator for internal emitter and low dose rate studies

被引:0
|
作者
Guy Garty
Yanping Xu
Gary W. Johnson
Lubomir B. Smilenov
Simon K. Joseph
Monica Pujol-Canadell
Helen C. Turner
Shanaz A. Ghandhi
Qi Wang
Rompin Shih
Robert C. Morton
David E. Cuniberti
Shad R. Morton
Carlos Bueno-Beti
Thomas L. Morgan
Peter F. Caracappa
Evagelia C. Laiakis
Albert J. Fornace
Sally A. Amundson
David J. Brenner
机构
[1] Columbia University,Radiological Research Accelerator Facility
[2] Columbia University,Center for Radiological Research
[3] Columbia University,David A. Gardner PET Imaging Research Center
[4] Columbia University,Department of Radiation Oncology
[5] Columbia University,Environmental Health and Safety
[6] Georgetown University,Department of Oncology, Lombardi Comprehensive Cancer Center
[7] Georgetown University,Department of Biochemistry and Molecular and Cellular Biology
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
In the long term, 137Cs is probably the most biologically important agent released in many accidental (or malicious) radiation disasters. It can enter the food chain, and be consumed, or, if present in the environment (e.g. from fallout), can provide external irradiation over prolonged times. In either case, due to the high penetration of the energetic γ rays emitted by 137Cs, the individual will be exposed to a low dose rate, uniform, whole body, irradiation. The VADER (VAriable Dose-rate External 137Cs irradiatoR) allows modeling these exposures, bypassing many of the problems inherent in internal emitter studies. Making use of discarded 137Cs brachytherapy seeds, the VADER can provide varying low dose rate irradiations at dose rates of 0.1 to 1.2 Gy/day. The VADER includes a mouse “hotel”, designed to allow long term simultaneous residency of up to 15 mice. Two source platters containing ~ 250 mCi each of 137Cs brachytherapy seeds are mounted above and below the “hotel” and can be moved under computer control to provide constant low dose rate or a varying dose rate mimicking 137Cs biokinetics in mouse or man. We present the VADER design and characterization of its performance over 18 months of use.
引用
收藏
相关论文
共 50 条
  • [1] VADER: a variable dose-rate external 137Cs irradiator for internal emitter and low dose rate studies
    Garty, Guy
    Xu, Yanping
    Johnson, Gary W.
    Smilenov, Lubomir B.
    Joseph, Simon K.
    Pujol-Canadell, Monica
    Turner, Helen C.
    Ghandhi, Shanaz A.
    Wang, Qi
    Shih, Rompin
    Morton, Robert C.
    Cuniberti, David E.
    Morton, Shad R.
    Bueno-Beti, Carlos
    Morgan, Thomas L.
    Caracappa, Peter F.
    Laiakis, Evagelia C.
    Fornace, Albert J., Jr.
    Amundson, Sally A.
    Brenner, David J.
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [2] Biofluid Metabolomics of Mice Exposed to External Low-Dose Rate Radiation in a Novel Irradiation System, the Variable Dose-Rate External 137Cs Irradiator
    Pannkuk, Evan L.
    Laiakis, Evagelia C.
    Girgis, Michael
    Garty, Guy Y.
    Morton, Shad R.
    Pujol-Canadell, Monica
    Ghandhi, Shanaz A.
    Amundson, Sally A.
    Brenner, David J.
    Fornace, Albert J., Jr.
    JOURNAL OF PROTEOME RESEARCH, 2021, 20 (11) : 5145 - 5155
  • [3] Effects of generational low dose-rate 137Cs internal exposure in descendant mice
    Nakajima, Hiroo
    Ohno, Mizuki
    Uno, Kazuko
    Endo, Satoru
    Suzuki, Masatoshi
    Toki, Hiroshi
    Saito, Tadashi
    INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 2024, 100 (11) : 1560 - 1578
  • [4] Dose-rate change due to 137Cs migration in soil
    Silant'ev, AN
    Silant'ev, KA
    Shkuratova, IG
    ATOMIC ENERGY, 1997, 83 (04) : 772 - 774
  • [5] DEVELOPMENT AND CHARACTERIZATION OF A NOVEL VARIABLE LOW DOSE-RATE IRRADIATOR FOR IN VIVO MOUSE STUDIES
    Olipitz, Werner
    Hembrador, Sheena
    Davidson, Matthew
    Yanch, Jacquelyn C.
    Engelward, Bevin P.
    HEALTH PHYSICS, 2010, 98 (05): : 727 - 734
  • [6] A new method to account for the depth distribution of 137Cs in soils in the calculation of external radiation dose-rate
    Timms, DN
    Smith, JT
    Cross, MA
    Kudelsky, AV
    Horton, G
    Mortlock, R
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2004, 72 (03) : 323 - 334
  • [7] RadNuc: A graphical user interface to deliver dose rate patterns encountered in nuclear medicine with a 137Cs irradiator
    Pasternack, Jordan B.
    Howell, Roger W.
    NUCLEAR MEDICINE AND BIOLOGY, 2013, 40 (02) : 304 - 311
  • [8] Temporal reduction of the external gamma dose rate due to 137Cs mobility in sandy beaches
    M. Rizzotto
    J. Toso
    H. Velasco
    M. Belli
    U. Sansone
    Journal of Radioanalytical and Nuclear Chemistry, 2009, 280 : 193 - 197
  • [9] Temporal reduction of the external gamma dose rate due to 137Cs mobility in sandy beaches
    Rizzotto, M.
    Toso, J.
    Velasco, H.
    Belli, M.
    Sansone, U.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2009, 280 (01) : 193 - 197
  • [10] Translocation dose-response curve for 137Cs γ-rays: Dose validation at various dose rate and changing dose rate conditions
    Amula, Saitya
    Rao, Subba T.
    Venkatraman, B.
    Kumar, Arul Anantha A.
    MUTATION RESEARCH-GENETIC TOXICOLOGY AND ENVIRONMENTAL MUTAGENESIS, 2021, 870