Validation of Omron HEM-9200T, a home blood pressure monitoring device for the upper arm, according to the American National Standards Institute/Association for the Advancement of Medical Instrumentation/International Organization for Standardization 81060-2:2013 protocol

被引:0
|
作者
Hakuo Takahashi
Kanako Saito
Nobuki Yakura
机构
[1] Biwako Central Hospital,Department of Cardiology
[2] Omron Healthcare Co.,Department of Technology Development
[3] Ltd.,Department of Cardiology
[4] Biwako Yoikuin Hospital,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The performance of Omron HEM-9200T for monitoring blood pressure (BP) in the upper arm was validated in accordance with the American National Standards Institute/Association for the Advancement of Medical Instrumentation/International Organization for Standardization (ANSI/AAMI/ISO) 81060-2:2013 protocol. The device was assessed by using it on 87 participants who fulfilled the inclusion criteria involving the ranges of arm circumference and systolic and diastolic BP provided by the protocol. Validation and data analysis were performed according to the protocol. In the ANSI/AAMI/ISO 81060-2:2013 validation procedure (criterion 1), the mean ± standard deviation of the differences between the test device and reference BP was −0.1 ± 5.06/1.2 ± 5.8 mmHg (systolic/diastolic). The mean differences between the two observers and Omron HEN-9200T were −0.1 ± 3.82 mmHg for systolic BP and 1.2 ± 5.34 mmHg for diastolic BP, fulfilling criterion 2 with an SD of ≤6.91 for SBP and ≤6.87 for DBP. These two ANSI/AAMI/ISO criteria were fulfilled.
引用
收藏
页码:416 / 419
页数:3
相关论文
共 24 条
  • [1] Validation of Omron HEM-9200T, a home blood pressure monitoring device for the upper arm, according to the American National Standards Institute/Association for the Advancement of Medical Instrumentation/International Organization for Standardization 81060-2:2013 protocol
    Takahashi, Hakuo
    Saito, Kanako
    Yakura, Nobuki
    JOURNAL OF HUMAN HYPERTENSION, 2022, 36 (04) : 416 - 419
  • [2] Validation of the Omron HEM-1040 Blood Pressure Monitor According to the American National Standards Institute/Association for the Advancement of Medical Instrumentation/International Organization for Standardization 81060-2:2013 Protocol
    Takahashi, Hakuo
    Saito, Kanako
    VASCULAR HEALTH AND RISK MANAGEMENT, 2020, 16 : 571 - 575
  • [3] Validation of Omron HEM-7600T, a wearable device for monitoring blood pressure, according to the American National Standards Institute/Association for the Advancement of Medical Instrumentation/International Organization for Standardization 81060-2:2013 protocol in the general population without arrhythmias
    Takahashi, Hakuo
    Saito, Kanako
    Hishiki, Yukiko
    BLOOD PRESSURE MONITORING, 2021, 26 (02) : 156 - 159
  • [4] Validation of the iHealth ambulatory blood pressure monitor in adults according to the American National Standards Institute/Association for the Advancement of Medical Instrumentation/International Organization for Standardization standard
    Kollias, Anastasios
    Ntineri, Angeliki
    Kyriakoulis, Konstantinos G.
    Stambolliu, Emelina
    Stergiou, George S.
    BLOOD PRESSURE MONITORING, 2018, 23 (02) : 115 - 116
  • [5] Validation of the professional device for blood pressure measurement Microlife WatchBP Office in adults and children according to the American National Standards Institute/Association for the Advancement of Medical Instrumentation/International Organization for Standardization standard
    Kollias, Anastasios
    Ntineri, Angeliki
    Kyriakoulis, Konstantinos G.
    Stambolliu, Emelina
    Lagou, Styliani
    Boubouchairopoulou, Nadia
    Stergiou, George S.
    BLOOD PRESSURE MONITORING, 2018, 23 (02) : 112 - 114
  • [6] Simultaneous validation of the SunTech CT40 automated blood pressure measurement device by the 1993 British Hypertension Society protocol and the Association for the Advancement of Medical Instrumentation/International Organization for Standardization 81060-2:2013 standard
    Friz, Hernan Polo
    Punzi, Veronica
    Petri, Francesco
    Orlandi, Riccardo
    Maggiolini, Daniele
    Friz, Melisa Polo
    Primitz, Laura
    Vighi, Giuseppe
    BLOOD PRESSURE MONITORING, 2017, 22 (05) : 298 - 301
  • [7] Validation of the YuWell YE660D oscillometric upper-arm blood pressure monitor for clinic and home in general population according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization Universal Standard (International Organization for Standardization 81060-2:2018) and the International Organization for Standardization Amendment 1. 2020
    Zhang, Hui-Jie
    Peng, Yue
    Zhang, Juan
    Zhang, Jin
    Teng, Li-Ni
    Zhang, Shu-Juan
    Zhou, De-Jun
    Long, Ming-Zhi
    BLOOD PRESSURE MONITORING, 2023, 28 (05) : 276 - 279
  • [8] Validation testing of five home blood pressure monitoring devices for the upper arm according to the ISO 81060-2:2018/AMD 1:2020 protocol
    Yaw Amofa Peprah
    Ji Young Lee
    Stephen D. Persell
    Journal of Human Hypertension, 2023, 37 : 134 - 140
  • [9] Validation of the JAMR F1701T (arm type) pressure monitor according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/ISO 81060-2:2018 protocol
    Li, Jing
    Han, Li-Hong
    Feng, Ru
    Wu, Li-Hao
    Cai, Jie
    Zeng, Tian-Ying
    Liu, Hui
    Zeng, Ya-Wen
    Zhou, Li
    Zhan, Zhong-Qun
    BLOOD PRESSURE MONITORING, 2023, 28 (03) : 163 - 166
  • [10] Validation testing of five home blood pressure monitoring devices for the upper arm according to the ISO 81060-2:2018/AMD 1:2020 protocol
    Peprah, Yaw Amofa
    Lee, Ji Young
    Persell, Stephen D. D.
    JOURNAL OF HUMAN HYPERTENSION, 2023, 37 (02) : 134 - 140