Compressive strength of interbody cages in the lumbar spine: The effect of cage shape, posterior instrumentation and bone density

被引:5
|
作者
Jost B. [1 ]
Cripton P.A. [1 ]
Lund T. [1 ]
Oxland T.R. [1 ]
Lippuner K. [2 ]
Jaeger Ph. [2 ]
Nolte L.-P. [1 ]
机构
[1] M.E. Müller Inst. for Biomech., University of Bern, Murtenstrasse 35
[2] Polyclinic of Medicine, University of Bern
关键词
Biomechanics; Compression; Fusion; Implant; Interbody; Posterior lumbar intervertebral fusion; Spine;
D O I
10.1007/s005860050043
中图分类号
学科分类号
摘要
One goal of interbody fusion is to increase the height of the degenerated disc space. Interbody cages in particular have been promoted with the claim that they can maintain the disc space better than other methods. There are many factors that can affect the disc height maintenance, including graft or cage design, the quality of the surrounding bone and the presence of supplementary posterior fixation. The present study is an in vitro biomechanical investigation of the compressive behaviour of three different interbody cage designs in a human cadaveric model. The effect of bone density and posterior instrumentation were assessed. Thirty-six lumbar functional spinal units were instrumented with one of three interbody cages: (1) a porous titanium implant with endplate fit (Stratec), (2) a porous, rectangular carbon-fibre implant (Brantigan) and (3) a porous, cylindrical threaded implant (Ray). Posterior instrumentation (USS) was applied to half of the specimens. All specimens were subjected to axial compression displacement until failure. Correlations between both the failure load and the load at 3 mm displacement with the bone density measurements were observed. Neither the cage design nor the presence of posterior instrumentation had a significant effect on the failure load. The loads at 3 mm were slightly less for the Stratec cage, implying lower axial stiffness, but were not different with posterior instrumentation. The large range of observed failure loads overlaps the potential in vivo compressive loads, implying that failure of the bone-implant interface may occur clinically. Preoperative measurements of bone density may be an effective tool to predict settling around interbody cages.
引用
收藏
页码:132 / 141
页数:9
相关论文
共 50 条
  • [1] Interbody cage stabilisation in the lumbar spine - Evaluation of cage design, posterior instrumentation and bone density
    Lund, T
    Oxland, TR
    Jost, B
    Cripton, P
    Grassmann, S
    Etter, C
    Nolte, LP
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (02): : 351 - 359
  • [2] Indirect Decompression of Lumbar Stenosis With Transpsoas Interbody Cages and Percutaneous Posterior Instrumentation
    Castellvi, Antonio E.
    Nienke, Thomas W.
    Marulanda, German A.
    Murtagh, Ryan D.
    Santoni, Brandon G.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2014, 472 (06) : 1784 - 1791
  • [3] Is one cage enough in posterior lumbar interbody fusion: A comparison of unilateral single cage interbody fusion to bilateral cages
    Fogel, Guy R.
    Toohey, John S.
    Neidre, Arvo
    Brantigan, John W.
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2007, 20 (01): : 60 - 65
  • [4] Posterior instrumentation using compressive laminar hooks and anterior interbody arthrodesis for the treatment of tuberculosis of the lower lumbar spine
    Kim, DJ
    Yun, YH
    Moon, SH
    Riew, KD
    SPINE, 2004, 29 (13) : E275 - E279
  • [5] Treatment of infections of the lumbar spine with single-staged posterior instrumentation, disc debridement and interbody fusion with titanium cages
    Cucchi, D.
    Deharde, L.
    Kasapovic, A.
    Gathen, M.
    Rommelspacher, Y.
    Bornemann, R.
    Wirtz, D. C.
    Pflugmacher, R.
    MLTJ-MUSCLES LIGAMENTS AND TENDONS JOURNAL, 2019, 9 (03): : 405 - 416
  • [6] Bone Remodeling Around Solid and Porous Interbody Cages in the Lumbar Spine
    Talukdar, Rahul Gautam
    Saviour, Ceby Mullakkara
    Tiwarekar, Kaustubh
    Dhara, Santanu
    Gupta, Sanjay
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2022, 144 (10):
  • [7] Posterior Lumbar Interbody Fusion Using a Unilateral Single Cage and a Local Morselized Bone Graft in the Degenerative Lumbar Spine
    Kim, Dong-Hee
    Jeong, Soon-Taek
    Lee, Sang-Soo
    CLINICS IN ORTHOPEDIC SURGERY, 2009, 1 (04) : 214 - 221
  • [8] Cage migration in spondylolisthesis treated with posterior lumbar interbody fusion using BAK cages
    Chen, L
    Yang, HL
    Tang, TS
    SPINE, 2005, 30 (19) : 2171 - 2175
  • [9] Management of Infected Transforaminal Lumbar Interbody Fusion Cage in Posterior Degenerative Lumbar Spine Surgery
    Chang, Chia-Wei
    Fu, Tsai-Sheng
    Chen, Wen-Jer
    Chen, Chien-Wen
    Lai, Po-Liang
    Chen, Shih-Hao
    WORLD NEUROSURGERY, 2019, 126 : E330 - E341
  • [10] Segmental stability and compressive strength of posterior lumbar interbody fusion implants
    Tsantrizos, A
    Baramki, HG
    Zeidman, S
    Steffen, T
    SPINE, 2000, 25 (15) : 1899 - 1907