Low-Cost and Active Control of Radiation of Wearable Medical Health Device for Wireless Body Area Network

被引:0
|
作者
Yong Jin
机构
[1] Changshu Institute of Technology,School of Computer Science & Engineering
来源
关键词
Cost optimization; Active control; Radiation; Wireless chargers; Wearable medical health care device; Wireless body area network;
D O I
暂无
中图分类号
学科分类号
摘要
Wearable devices, wireless networks and body area networks have become an effective way to solve the problem of human health monitoring and care. However, the radiation problems of wireless devices, the power supply problems of wearable devices and the deployment of body area networks have become obstacles to their wide application in the field of health care. In order to solve the above problems, this paper studies and designs a wearable health medical body area network which is convenient for human health monitoring and medical care, starting from low-cost deployment of wireless wearable devices and active control of wireless radiation. Firstly, in order to avoid replacing equipment batteries, improve the relay and data aggregation capabilities of wireless body area network, and reduce the communication and computing load of edge devices, a deployment scheme of wireless medical health wearable devices is designed based on the optimal segmentation algorithm of Steiner spanning tree. Then, in order to minimize the charging cost and maximize the global charging utility of single source and multiple points in a finite time slot, an approximate algorithm for the optimal charging sequence based on 01 knapsack problem, i.e., the access path of wireless wearable devices, is designed. Then, an active radiation control algorithm for wearable medical health body area network is proposed, which can actively control the transmission power and radiation status of these wireless devices. Finally, simulation results show that the proposed algorithm is better than battery-powered wireless body area network and wireless rechargeable body area network, 16% and 44% reduction of devices, 25%和13% reduction of energy consumption, 26% reduction of radiation, and 5.18 and 1.13 times improvement of signal quality.
引用
收藏
相关论文
共 45 条
  • [1] Latré B(2011)A survey on wireless body area networks Wirel. Netw 17 1-18
  • [2] Braem B(2011)Wireless Body Area Network for Medical Healthcare IETE Tech. Rev. 28 362-371
  • [3] Moerman I(2012)A Survey of Routing Protocols in Wireless Body Area Networks for Healthcare Applications International Journal of E-Health and Medical Communications (IJEHMC) 3 1-18
  • [4] Jain PC(2014)Recent trends in Wireless Body Area Network (WBAN) research and cognition based adaptive WBAN architecture for healthcare Heal. Technol. 4 239-244
  • [5] Ben Elhadj H(2017)Fog-Based Healthcare Architecture for Wearable Body Area Network Journal of Medical Imaging & Health Informatics 7 1409-1418
  • [6] Chaari L(2015)Network-assisted Smart Access Point Selection for Pervasive Real-time mHealth Applications Procedia Computer Science 63 317-324
  • [7] Kamoun L(2018)Wearable Circular Ring Slot Antenna With EBG Structure for Wireless Body Area Network IEEE Antennas & Wireless Propagation Letters 17 434-437
  • [8] Rathee D(2017)Experimental study of a wearable aperture-coupled patch antenna for wireless body area network Microw. Opt. Technol. Lett. 59 761-766
  • [9] Rangi S(2017)Wearable PIFA antenna implemented on jean substrate for wireless body area network Journal of Electromagnetic Waves & Applications 31 1-11
  • [10] Chakarvarti SK(2012)Optimised design and development of a bio-medical healthcare device through quality function deployment (QFD) Int. J. Electron. Healthc. 7 68-87