An innovative connection proposal for the precast prestressed column-foundation connection

被引:0
|
作者
Mehmet Uzun
Mustafa Tolga Cogurcu
Mehmet Akif Arslan
机构
[1] Karamanoglu Mehmetbey University,Department of Civil Engineering, Faculty of Engineering
[2] Konya Technical University,Department of Civil Engineering, Faculty of Engineering and Natural Sciences
来源
Materials and Structures | 2023年 / 56卷
关键词
Column to foundation connections; Precast prestressed concrete; Seismic performance; Cyclic loading; Moment-resisting connections; Monolithic-like connections;
D O I
暂无
中图分类号
学科分类号
摘要
Prefabricated buildings are highly preferred due to their many advantages such as rapid production, low cost. However, it has been seen with the earthquakes in the past years that prefabricated buildings are insufficient in terms of seismic performance because of connection problems of structural members. Therefore, studies about prefabricated connection types have increased in recent years. In this study, an innovative connection was proposed for prefabricated prestressed foundation-column connection that is easy to assemble, preventing workmanship errors, cost and time-effective compared with socket connection. In the study, samples were produced for 5 different connections. The produced 1/2 scale samples were tested under cyclic lateral loading. Structural parameters such as strength, stiffness degradation, ductility, energy dissipation capacity, equivalent viscous damping ratio were obtained from test results. The obtained parameters were interpreted, and the seismic behavior of the samples was compared. As a result, it was seen that the proposed connection provided structural parameters such as sufficient strength and rigidity that can be applied in seismic regions.
引用
下载
收藏
相关论文
共 50 条
  • [1] An innovative connection proposal for the precast prestressed column-foundation connection
    Uzun, Mehmet
    Cogurcu, Mustafa Tolga
    Arslan, Mehmet Akif
    MATERIALS AND STRUCTURES, 2023, 56 (07)
  • [2] Effect of Mechanical Splice to Seismic Performance of Precast Column-Foundation Connection
    Zhang, Wei
    Lee, Deuckhang
    ACI Structural Journal, 2024, 121 (05) : 133 - 146
  • [3] Experimental investigation of a new precast column-foundation connection under cyclic loading
    Cogurcu, Mustafa Tolga
    Uzun, Mehmet
    JOURNAL OF BUILDING ENGINEERING, 2022, 50
  • [4] Influence of different mechanical column-foundation connection devices on the seismic behaviour of precast structures
    Bruno Dal Lago
    Giandomenico Toniolo
    Marco Lamperti Tornaghi
    Bulletin of Earthquake Engineering, 2016, 14 : 3485 - 3508
  • [5] Experimental study of CFST embedded precast concrete bridge column-foundation connection with studs
    Jiao, Chiyu
    Liu, Wenbo
    Li, Yangjie
    Shi, Wenhao
    Long, Peiheng
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2023, 168
  • [6] Influence of different mechanical column-foundation connection devices on the seismic behaviour of precast structures
    Dal Lago, Bruno
    Toniolo, Giandomenico
    Lamperti Tornaghi, Marco
    BULLETIN OF EARTHQUAKE ENGINEERING, 2016, 14 (12) : 3485 - 3508
  • [7] Experimental and numerical investigation of a proposed monolithic-like precast concrete column-foundation connection
    Pul, Selim
    Senturk, Mehmet
    Ilki, Alper
    Hajirasouliha, Iman
    ENGINEERING STRUCTURES, 2021, 246
  • [8] Column-foundation connection for pre-cast elements
    Dolara, E
    Di Niro, G
    SYSTEM-BASED VISION FOR STRATEGIC AND CREATIVE DESIGN, VOLS 1-3, 2003, : 1121 - 1125
  • [9] EXPERIMENTAL AND NUMERICAL STUDY ON COLUMN-FOUNDATION CONNECTION THROUGH EXTERNAL SOCKET
    Ma, Haiying
    Lai, Minghui
    Shi, Xuefei
    Cao, Zhen
    Zhou, Junyong
    JOURNAL OF CIVIL ENGINEERING AND MANAGEMENT, 2021, 27 (03) : 162 - 174
  • [10] Prestressed bolting in precast concrete beam-column connection
    Hanaor, A
    Ben-Arroyo, A
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 1998, 128 (02) : 144 - 153