Microwave SQUID Multiplexing of Metallic Magnetic Calorimeters: Status of Multiplexer Performance and Room-Temperature Readout Electronics Development

被引:0
|
作者
M. Wegner
N. Karcher
O. Krömer
D. Richter
F. Ahrens
O. Sander
S. Kempf
M. Weber
C. Enss
机构
[1] Heidelberg University,Kirchhoff
[2] Karlsruhe Institute of Technology,Institute for Physics
[3] Heidelberg University,Institute for Data Processing and Electronics
[4] Karlsruhe Institute of Technology (KIT),HEiKA
来源
关键词
Metallic magnetic calorimeters; MMC; Microwave SQUID multiplexer; Flux ramp modulation; Software-defined radio;
D O I
暂无
中图分类号
学科分类号
摘要
To our present best knowledge, microwave SQUID multiplexing (μ\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\mu $$\end{document}MUXing) is the most suitable technique for reading out large-scale low-temperature microcalorimeter arrays that consist of hundreds or thousands of individual pixels which require a large readout bandwidth per pixel. For this reason, the present readout strategy for metallic magnetic calorimeter (MMC) arrays combining an intrinsic fast signal rise time, an excellent energy resolution, a large energy dynamic range, a quantum efficiency close to 100%\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$100\%$$\end{document} as well as a highly linear detector response is based on μ\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\mu $$\end{document}MUXing. Within this paper, we summarize the state of the art in MMC μ\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\mu $$\end{document}MUXing and discuss the most recent results. This particularly includes the discussion of the performance of a 64-pixel detector array with integrated, on-chip microwave SQUID multiplexer, the progress in flux ramp modulation of MMCs as well as the status of the development of a software-defined radio-based room-temperature electronics which is specifically optimized for MMC readout.
引用
收藏
页码:462 / 475
页数:13
相关论文
共 4 条
  • [1] Microwave SQUID Multiplexing of Metallic Magnetic Calorimeters: Status of Multiplexer Performance and Room-Temperature Readout Electronics Development
    Wegner, M.
    Karcher, N.
    Kroemer, O.
    Richter, D.
    Ahrens, F.
    Sander, O.
    Kempf, S.
    Weber, M.
    Enss, C.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2018, 193 (3-4) : 462 - 475
  • [2] Microwave SQUID Multiplexer for the Readout of Metallic Magnetic Calorimeters
    S. Kempf
    L. Gastaldo
    A. Fleischmann
    C. Enss
    Journal of Low Temperature Physics, 2014, 175 : 850 - 860
  • [3] Microwave SQUID Multiplexer for the Readout of Metallic Magnetic Calorimeters
    Kempf, S.
    Gastaldo, L.
    Fleischmann, A.
    Enss, C.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2014, 175 (5-6) : 850 - 860
  • [4] Demonstration of a scalable frequency-domain readout of metallic magnetic calorimeters by means of a microwave SQUID multiplexer
    Kempf, Sebastian
    Wegner, Mathias
    Fleischmann, Andreas
    Gastaldo, Loredana
    Herrmann, Felix
    Papst, Maximilian
    Richter, Daniel
    Enss, Christian
    AIP ADVANCES, 2017, 7 (01)