Passivity-Based Design for LCL-Filtered Grid-Connected Inverters with Inverter Current Control and Capacitor-Current Active Damping

被引:0
|
作者
Zeyang Fan
Hong Yi
Jian Xu
Kun Xie
机构
[1] Shanghai Jiao Tong University,Key Laboratory of Marine Intelligent Equipment and System (Ministry of Education)
[2] China Ship Development and Design Center,undefined
关键词
Passivity; Inverter current control; Capacitor-current active damping; Grid-connected inverter; filter;
D O I
暂无
中图分类号
学科分类号
摘要
Passivity-based design gains much popularity in grid-connected inverters (GCIs) since it enables system stability regardless of the uncertain grid impedance. This paper devotes to a systematic passivity-based design guidance for the LCL-filtered GCI with inverter current control and capacitor-current active damping. It is found that the passivity can be guaranteed with an optimal damping gain of the capacitor-current active damping, but it suffers from both the filter parameter drift and the lagging phase of the current regulator, especially at the one-sixth sampling frequency. To address this issue, a phase-lead compensation is introduced in series with the current regulator, which helps to enhance the full-band passivity and high robustness against the aforementioned challenge. Experiments are conducted to confirm the theoretical expectation.
引用
收藏
页码:1541 / 1549
页数:8
相关论文
共 50 条
  • [1] Passivity-Based Design for LCL-Filtered Grid-Connected Inverters with Inverter Current Control and Capacitor-Current Active Damping
    Fan, Zeyang
    Yi, Hong
    Xu, Jian
    Xie, Kun
    [J]. JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2024, 19 (03) : 1541 - 1549
  • [2] Passivity Enhancement for LCL-Filtered Inverter With Grid Current Control and Capacitor Current Active Damping
    Wang, Xuehua
    He, Yuying
    Pan, Donghua
    Zhang, Hao
    Ma, Yixiao
    Ruan, Xinbo
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2022, 37 (04) : 3801 - 3812
  • [3] Research on Stability of Grid-Connected LCL-Filtered Inverter with Capacitor Current Feedback Active Damping Control
    Xu, A. Jinming
    Xie, B. Shaojun
    Kan, C. Jiarong
    Zhang, D. Binfeng
    [J]. 2015 9TH INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND ECCE ASIA (ICPE-ECCE ASIA), 2015, : 682 - 687
  • [4] An Optimized Parameter Design Method for Passivity-Based Control in a LCL-Filtered Grid-Connected Inverter
    Zheng, Faban
    Wu, Weimin
    Chen, Bolin
    Koutroulis, Eftichios
    [J]. IEEE ACCESS, 2020, 8 : 189878 - 189890
  • [5] Active Damping-Based Control for Grid-Connected LCL-Filtered Inverter With Injected Grid Current Feedback Only
    Xu, Jinming
    Xie, Shaojun
    Tang, Ting
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2014, 61 (09) : 4746 - 4758
  • [6] Passivity-based Design of Capacitor-Current-Feedback Active Damping for LCL-Filtered Inverter Considering Computation Delay Reduction
    Ma, Yixiao
    Xu, Lin
    Wang, Xuehua
    He, Yuying
    Ruan, Xinbo
    Liu, Fuxin
    [J]. 2020 IEEE 11TH INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS FOR DISTRIBUTED GENERATION SYSTEMS (PEDG), 2020, : 364 - 369
  • [7] Current Control and Active Damping for Single Phase LCL-Filtered Grid Connected Inverter
    Alshiekh, Mohammad
    Marouf, Alaa
    Kubeitari, Muhieddin
    [J]. JOURNAL OF CONTROL SCIENCE AND ENGINEERING, 2020, 2020
  • [8] Enhanced Stability of Capacitor-Current Feedback Active Damping for LCL-Filtered Grid Converters
    Xin, Zhen
    Wang, Xiongfei
    Loh, Poh Chiang
    Blaabjerg, Frede
    [J]. 2015 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2015, : 4729 - 4736
  • [9] Optimization of Weighted Current Control for Grid-Connected LCL-Filtered Inverters
    Xu, Jinming
    Xie, Shaojun
    [J]. 2013 IEEE ECCE ASIA DOWNUNDER (ECCE ASIA), 2013, : 1170 - 1175