Incidence of Stent Under-Deployment as a Cause of in-Stent Restenosis in Long Stents

被引:0
|
作者
Olivier F. Bertrand
Robert De Larochellière
Michel Joyal
Raoul Bonan
Rosaire Mongrain
Jean-Claude Tardif
机构
[1] JLaval Hospital,Quebec Heart
[2] Montreal Heart Institute,Lung Institute
关键词
brachytherapy; IVUS; restenosis; stent;
D O I
暂无
中图分类号
学科分类号
摘要
Although stent under-deployment (SU) has been associated with increased risk of in-stent restenosis, little data have been reported on the incidence of SU in patients presenting with clinical in-stent restenosis. In 59 patients referred for vascular brachytherapy and showing angiographic in-stent restenosis, we sought (1) to determine the incidence of SU using standard intravascular ultrasound (IVUS) criteria (2) to evaluate the effects of repeat angioplasty on further stent expansion. Stented length was 32 ± 17 mm and diameter stenosis was 75 ± 14%. Before re-intervention, the incidence of reduced absolute values of minimal stent cross-sectional area (MSCSA) varied from 69%(≤8 mm2) to 15%(≤5 mm2). After re-intervention, the incidence decreased to 24%(≤8 mm2)(p= 0.0001) and 0%(≤5 mm2)(p= 0.005). Before re-intervention, SU as assessed by relative criteria varied from 21%(80% mean reference lumen area or 90% minimum distal reference lumen area) to 28%(100% minimum reference lumen area). After re-intervention, the incidence of SU varied from 7%(90% minimum distal reference lumen area)(p= 0.0001 vs. pre) to 24%(55% mean reference EEM area)(p= ns). No change in strut apposition (97% pre vs. 100% post) nor in symmetry index (100% pre vs. post) was noted. From all criteria, the 90 and 100% minimum reference lumen area criteria were the most altered by repeat balloon dilatation, 21% pre vs. 7% post and 28% pre vs. 11% post, respectively. In conclusion, among patients presenting with severe angiographic in-stent restenosis, a significant number showed signs of SU whose incidence varied according to applied criteria. Significant stent re-expansion can be obtained following IVUS-guided repeat angioplasty irrespective of initial SU criteria.
引用
收藏
页码:279 / 284
页数:5
相关论文
共 50 条
  • [1] Incidence of stent under-deployment as a cause of in-stent restenosis in long stents
    Bertrand, OF
    De Larochellière, R
    Joyal, M
    Bonan, R
    Mongrain, R
    Tardif, JC
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2004, 20 (04): : 279 - 284
  • [2] Incidence of stent under-deployment as a cause of in-stent restenosis
    DeLa Rochellière, R
    Bertrand, OF
    Joyal, M
    Bonan, R
    Tardif, JC
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (05) : 34A - 34A
  • [3] Incidence of stent under-deployment as a cause of in-stent restenosis in long stents Take your lesson !
    William Wijns
    The International Journal of Cardiovascular Imaging, 2004, 20 : 529 - 530
  • [4] Incidence of stent under-deployment as a cause of in-stent restenosis in long stents - Take your lesson!
    Wijns, W
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2004, 20 (06): : 529 - 530
  • [5] In-stent restenosis and stent compression in iliofemoral venous stents
    Saleem, Taimur
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, 12 (02) : 1658 - 1659
  • [6] Response to "In-stent restenosis and stent compression in iliofemoral venous stents"
    Liu, Hong
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, 12 (02)
  • [7] Drug eluting stents and modern stent technologies for in-stent restenosis
    Werner, Martin
    JOURNAL OF CARDIOVASCULAR SURGERY, 2017, 58 (04): : 497 - 500
  • [8] Stents for the treatment of in-stent restenosis: Long-term outcome
    Holmes, DR
    Berger, PB
    Rihal, CS
    Garratt, KN
    Bell, MR
    Mathew, V
    Bresnahan, JF
    Barsness, GW
    Grill, D
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 80A - 81A
  • [9] On the Use of Smart Stents for Monitoring In-Stent Restenosis
    Keikhosravy, Kamyar
    Zargaran-Yazd, Arash
    Mirabbasi, Shahriar
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 3231 - 3234
  • [10] An overview of in-stent restenosis in iliofemoral venous stents
    Saleem, Taimur
    Raju, Seshadri
    JOURNAL OF VASCULAR SURGERY-VENOUS AND LYMPHATIC DISORDERS, 2022, 10 (02) : 492 - +