Performance evaluation of controllers applied to power generator set operating with wastewater biogas

被引:0
|
作者
Pedro Diniz
Lucas da Costa
Jarbas da Silveira
Giovanni Barroso
William Barcellos
机构
[1] Universidade Federal do Ceará,
来源
Electrical Engineering | 2021年 / 103卷
关键词
Biogas; Fuzzy logic; Generator set modeling; Particle swarm optimization; Power generation control;
D O I
暂无
中图分类号
学科分类号
摘要
The improvement of renewable energy resource-based power plants is a real and modern global challenge, and therefore, biogas applied in reciprocating Internal Combustion Engines is an excellent alternative to this challenging task. Biogas can be obtained from various sources and its composition varies according to the biomass type used in its production, but the majority of this fuel is composed of methane (CH4\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\text {CH}_4$$\end{document}) and carbon dioxide (CO2\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\text {CO}_2$$\end{document}). However, there is no reliable control to hold the power quality following Brazilian Electricity Regulatory Agency (ANEEL) requirements. In such a context, this paper presents four control schemes to assure the power quality by a generator set operating with biogas from wastewater treatment. In order to accomplish it, a mathematical model was developed to represent the mechanical and electrical phenomena involved in the generation process. These control systems were evaluated in load and biogas composition variation scenario at same time in an environment developed in MATLAB/Simulink. The performed tests showed that the scheme composed by two Proportional Integral Derivative in parallel operation switched by fuzzy logic controller with particle swarm optimization tuning is better than all schemes proposed in this work and this layout enables the power plant to remain connected to the grid in all simulation scenario, because power frequency and voltage remained within limits imposed by national standards.
引用
收藏
页码:753 / 768
页数:15
相关论文
共 50 条
  • [1] Performance evaluation of controllers applied to power generator set operating with wastewater biogas
    Diniz, Pedro
    da Costa, Luca
    da Silveira, Jarbas
    Barroso, Giovanni
    Barcellos, William
    ELECTRICAL ENGINEERING, 2021, 103 (01) : 753 - 768
  • [2] Performance evaluation of biogas fueled generator set
    de Aguiar, Pedro Lima
    Santiago Diniz, Pedro Henrique
    da Costa, Lucas Ribeiro
    Rattes, Rodrigo Aragao
    Lopes, Arthur Tome
    Leitao, Renato Carrha
    Barcellos, William Magalhaes
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2021, 43 (09)
  • [3] Performance evaluation of biogas fueled generator set
    Pedro Lima de Aguiar
    Pedro Henrique Santiago Diniz
    Lucas Ribeiro da Costa
    Rodrigo Aragão Rattes
    Arthur Tomé Lopes
    Renato Carrhá Leitão
    William Magalhães Barcellos
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2021, 43
  • [4] Utilization of biogas for generator set fuel: performance and emission characteristics
    Muhajir, Khairul
    Badrawada, I. G.
    Susastriawan, A. A. P.
    BIOMASS CONVERSION AND BIOREFINERY, 2019, 9 (04) : 695 - 698
  • [5] Utilization of biogas for generator set fuel: performance and emission characteristics
    Khairul Muhajir
    I. G. Badrawada
    A. A. P. Susastriawan
    Biomass Conversion and Biorefinery, 2019, 9 : 695 - 698
  • [6] Performance evaluation of an engine-generator set operating on high butane content LPG fuel
    Alberto Romero-Piedrahita, Carlos
    Mejia-Calderon, Luz Adriana
    UIS INGENIERIAS, 2022, 21 (01): : 143 - 162
  • [7] Performance Evaluation of a Hybrid Grid-Connected Photovoltaic Biogas-Generator Power System
    Al-Najjar, Heyam
    Pfeifer, Christoph
    Al Afif, Rafat
    El-Khozondar, Hala J.
    ENERGIES, 2022, 15 (09)
  • [8] INVESTIGATIONAL STUDY OF ENVIRONMENTAL PERFORMANCE OF POWER GENERATOR OPERATING ON GENERATOR GAS
    Kukharets, Savelii
    Sukmaniuk, Olena
    Yarosh, Yaroslav
    Kovalchuk, Vladyslav
    20TH INTERNATIONAL SCIENTIFIC CONFERENCE ENGINEERING FOR RURAL DEVELOPMENT, 2021, : 444 - 450
  • [9] Performance Assessment of a Small Biogas-fuelled Power Generator Prototype
    Himabindu, M.
    Ravikrishna, R. V.
    JOURNAL OF SCIENTIFIC & INDUSTRIAL RESEARCH, 2014, 73 (12): : 781 - 785