Management of pediatric radiation dose using Philips digital radiography

被引:0
|
作者
U. Neitzel
机构
[1] Philips Medical Systems,
来源
Pediatric Radiology | 2004年 / 34卷
关键词
Digital radiography; Radiation dose; Image quality; Pediatrics;
D O I
暂无
中图分类号
学科分类号
摘要
Digital radiography systems based on flat-panel detectors have been introduced into clinical practice in the past few years. The high detective quantum efficiency of these detectors allows the radiation dose to be reduced while maintaining image quality, an issue particularly significant for pediatric radiography. Another important aspect for dose optimization and monitoring is the integration of the detector into a computer-controlled x-ray examination system. This enables full control and complete reporting of all dose-relevant exposure parameters, including the determination of the exposure indicator and the patient dose (kerma-area product). In this paper the implementation of these principles in the Philips Digital Diagnost DR system is described and their relevance for pediatric applications is discussed.
引用
收藏
页码:S227 / S233
相关论文
共 50 条
  • [1] Management of pediatric radiation dose using Philips digital radiography
    Neitzel, U
    PEDIATRIC RADIOLOGY, 2004, 34 (Suppl 3) : S227 - S233
  • [2] Management of pediatric radiation dose using Philips digital radiography - Discussion
    Burns, C
    Willis
    Seibert
    MacCutcheon
    Junewick, J
    Schaetzing
    Gorman, A
    Arreola
    Buczkowski, D
    Neitzel
    Jabri
    Aelvoet, R
    Huda
    Podimannil, P
    Westra, S
    Shope, T
    Slovis, T
    Kleinman, P
    Don
    PEDIATRIC RADIOLOGY, 2004, 34 : S234 - S241
  • [3] Management of pediatric radiation dose using Canon digital radiography
    M. Arreola
    L. Rill
    Pediatric Radiology, 2004, 34 : S221 - S226
  • [4] Management of pediatric radiation dose using Canon digital radiography
    Arreola, M
    Rill, L
    PEDIATRIC RADIOLOGY, 2004, 34 (Suppl 3) : S221 - S226
  • [5] Management of pediatric radiation dose using GE’s Revolution digital radiography systems
    K.N. Jabri
    R. Uppaluri
    P. Xue
    Pediatric Radiology, 2004, 34 : S215 - S220
  • [6] Management of pediatric radiation dose using GE's Revolution digital radiography systems
    Jabri, KN
    Uppaluri, R
    Xue, P
    PEDIATRIC RADIOLOGY, 2004, 34 (Suppl 3) : S215 - S220
  • [7] Management of pediatric radiation dose using Fuji computed radiography
    D.W. MacCutcheon
    Pediatric Radiology, 2004, 34 : S201 - S206
  • [8] Improving pediatric radiation dose management using Agfa digital radiography DICOM header information
    Juste, B.
    Villaescusa, N.
    Granero, D.
    Verdu, G.
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 4457 - +
  • [9] Management of pediatric radiation dose using Fuji computed radiography
    MacCutcheon, DW
    PEDIATRIC RADIOLOGY, 2004, 34 (Suppl 3) : S201 - S206
  • [10] Management of pediatric radiation dose using Agfa computed radiography
    R. Schaetzing
    Pediatric Radiology, 2004, 34 : S207 - S214