Critical heat flux in forced convective boiling with a plane jet (Revised correlation for saturated condition)

被引:0
|
作者
M. Monde
X. Wang
机构
[1] Department of Mechanical Engineering Saga University,
[2] 1 Honjo-machi,undefined
[3] Saga-shi,undefined
[4] Saga 840-8502,undefined
[5] Japan,undefined
来源
Heat and Mass Transfer | 2000年 / 36卷
关键词
Heat Flux; Heated Surface; Saturated Condition; System Pressure; R113;
D O I
暂无
中图分类号
学科分类号
摘要
 Critical heat flux (CHF) has been measured in saturated forced convective boiling with a wall jet on a rectangular heated surface of 40 and 80 mm in length and 20 mm in width. The jet velocity is varied from 3 to 15  m/s, and the system pressure is 0.1, 0.2, and 0.4 MPa for R113. It is found that the existing correlation for saturation condition can be applied to the CHF at high and low ρl/ρg values (e.g. water and R22), but hardly to the CHF at medium ρl/ρg values (e.g. R113 at 0.2 and 0.4 MPa). A revised correlation is proposed to predict most of the CHF data within an accuracy of ±25%.
引用
收藏
页码:97 / 101
页数:4
相关论文
共 50 条