False lumen pressure estimation in type B aortic dissection using 4D flow cardiovascular magnetic resonance: comparisons with aortic growth

被引:0
|
作者
David Marlevi
Julio A. Sotelo
Ross Grogan-Kaylor
Yunus Ahmed
Sergio Uribe
Himanshu J. Patel
Elazer R. Edelman
David A. Nordsletten
Nicholas S. Burris
机构
[1] Massachusetts Institute of Technology,Institute for Medical Engineering and Science
[2] Universidad de Valparaíso,School of Biomedical Engineering
[3] Pontificia Universidad Católica de Chile,Biomedical Imaging Center
[4] ANID-Millennium Science Initiative Program-Millennium Nucleus in Cardiovascular Magnetic Resonance,Department of Radiology, Schools of Medicine
[5] Pontificia Universidad Católica de Chile,Department of Biomedical Engineering
[6] University of Michigan,Department of Cardiac Surgery
[7] University of Michigan,School of Biomedical Engineering and Imaging Sciences
[8] King’s College London,Department of Radiology
[9] University of Michigan,undefined
关键词
Type B aortic dissection; 4D flow magnetic resonance imaging; 4D flow MRI; False lumen; Aortic growth rate; False lumen ejection fraction; Maximum systolic deceleration rate; Relative pressure;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [1] False lumen pressure estimation in type B aortic dissection using 4D flow cardiovascular magnetic resonance: comparisons with aortic growth
    Marlevi, David
    Sotelo, Julio A.
    Grogan-Kaylor, Ross
    Ahmed, Yunus
    Uribe, Sergio
    Patel, Himanshu J.
    Edelman, Elazer R.
    Nordsletten, David A.
    Burris, Nicholas S.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2021, 23 (01)
  • [2] False lumen rotational flow and aortic stiffness are associated with aortic growth rate in patients with chronic aortic dissection of the descending aorta: a 4D flow cardiovascular magnetic resonance study
    Aroa Ruiz-Muñoz
    Andrea Guala
    Lydia Dux-Santoy
    Gisela Teixidó-Turà
    Maria Luz Servato
    Filipa Valente
    Juan Garrido-Oliver
    Laura Galian-Gay
    Laura Gutiérrez
    Rubén Fernandez-Galera
    Guillem Casas
    Teresa González-Alujas
    Hug Cuéllar-Calabria
    Kevin M. Johnson
    Oliver Wieben
    Ignacio Ferreira-Gonzalez
    Arturo Evangelista
    Jose Rodriguez-Palomares
    Journal of Cardiovascular Magnetic Resonance, 24
  • [3] False lumen rotational flow and aortic stiffness are associated with aortic growth rate in patients with chronic aortic dissection of the descending aorta: a 4D flow cardiovascular magnetic resonance study
    Ruiz-Munoz, Aroa
    Guala, Andrea
    Dux-Santoy, Lydia
    Teixido-Tura, Gisela
    Servato, Maria Luz
    Valente, Filipa
    Garrido-Oliver, Juan
    Galian-Gay, Laura
    Gutierrez, Laura
    Fernandez-Galera, Ruben
    Casas, Guillem
    Gonzalez-Alujas, Teresa
    Cuellar-Calabria, Hug
    Johnson, Kevin M.
    Wieben, Oliver
    Ferreira-Gonzalez, Ignacio
    Evangelista, Arturo
    Rodriguez-Palomares, Jose
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2022, 24 (01)
  • [4] Aortic Diameter, True Lumen, and False Lumen Growth Rates in Chronic Type B Aortic Dissection
    Blount, Kevin J.
    Hagspiel, Klaus D.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (05) : W222 - W229
  • [5] Effect of Endovascular Treatment on the Pressure in the False Lumen of Type B Aortic Dissection
    Gokalp, Orhan
    Yesilkaya, Nihan Karakas
    Iner, Hasan
    Besir, Yuksel
    Gokalp, Gamze
    Yilik, Levent
    Gurbuz, Ali
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2019, 58 (04) : 629 - 629
  • [6] Partial thrombosis of the false lumen influences aortic growth in type B dissection
    Tolenaar, Jip L.
    Eagle, Kim A.
    Jonker, Frederik H. W.
    Moll, Frans L.
    Elefteriades, John A.
    Trimarchi, Santi
    ANNALS OF CARDIOTHORACIC SURGERY, 2014, 3 (03) : 275 - 277
  • [7] Clinical Prediction Model of Growth Rate in Type B Aortic Dissection Using 4D Flow MRI
    Maroun, Anthony
    Jarvis, Kelly
    Baraboo, Justin
    Pradella, Maurice
    Weiss, Elizabeth
    Chu, Stanley
    Kilinc, Ozden
    Berhane, Haben
    Mehta, Chris
    Malaisrie, S.
    Hoel, Andrew
    Markl, Michael
    Allen, Bradley D.
    CIRCULATION, 2022, 146
  • [8] Proximal false lumen thrombosis is associated with low false lumen pressure and fewer complications in type B aortic dissection
    Parker, Louis P.
    Reutersberg, Benedikt
    Syed, Maaz B. J.
    Munshi, Bijit
    Richards, Samantha
    Kelsey, Lachlan J.
    Sakalihasan, Natzi
    Eckstein, Hans-Henning
    Norman, Paul E.
    Doyle, Barry J.
    JOURNAL OF VASCULAR SURGERY, 2022, 75 (04) : 1181 - +
  • [9] Expansion of False Lumen Led to Rapid Aortic Enlargement in Type B Aortic Dissection
    Matsushita, Akihito
    Hattori, Takashi
    Mihara, Wahei
    JOURNAL OF VASCULAR SURGERY, 2019, 69 (06) : E63 - E64
  • [10] A Case Report of Type B Aortic Dissection With Ruptured False Lumen
    Suthar, Pokhraj P.
    Hussein, Mohamed Z.
    Gaddikeri, Ramya
    Shah, Palmi
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (07)