There is a growing interest in three-dimensional computed tomography (3D-CT) as a research tool for the study of bone, joint anatomy, and kinematics. However, when CT data are processed and handled manually using image processing programs to yield 3D image and coordinate value, systematic and random errors should be validated. We evaluated the accuracy and reliability of length measurement on CT with OsiriX software. 3D-CT scans were made of 14 frozen pig knees with five transosseous holes in the metaphyseal portion of femur. The lengths between tunnel orifices were measured using Mitutoyo Digimatic digital calipers to establish the gold standard, and with the OsiriX program in 3D multi-planar reformatting mode for comparison. All measurements were recorded by a principal (replicate 1, trial 1) and a secondary observer (replicate 2, trial 1) and were repeated once by each observer (trial 2). The mean differences between OsiriX and real measurements were less than 0.1 mm in both replicates, and maximum differences were less than 0.3 mm. There were no significant differences between the replicates and real measurements (p = 0.544 and 0.622 for replicates 1 and 2, respectively). The intraclass correlation coefficients (ICC) were very high between trials and between replicates (ICC = 0.998 and 0.999, respectively). For kinematic analysis of the knees, length measurements on 3D-CT using OsiriX program can be used as alternatives to real measurements with less than 0.3-mm accuracy and very high reliability.
引用
收藏
页码:486 / 491
页数:5
相关论文
共 50 条
  • [1] Accuracy and Reliability of Length Measurements on Three-Dimensional Computed Tomography Using Open-Source OsiriX Software
    Kim, Gihyeon
    Jung, Ho-Joong
    Lee, Han-Jun
    Lee, Jae-Sung
    Koo, Seungbum
    Chang, Seung-Hwan
    [J]. JOURNAL OF DIGITAL IMAGING, 2012, 25 (04) : 486 - 491
  • [2] Demonstration of the Adamkiewicz Artery by Multidetector Computed Tomography Angiography Analysed with the Open-Source Software OsiriX
    Melissano, G.
    Bertoglio, L.
    Civelli, V.
    Amato, A. C. Moraes
    Coppi, G.
    Civilini, E.
    Calori, G.
    De Cobelli, F.
    Del Maschio, A.
    Chiesa, R.
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2009, 37 (04) : 395 - 400
  • [3] Accuracy of Software-Based Three-Dimensional Root Canal Length Measurements Using Cone-Beam Computed Tomography
    Tchorz, J. P.
    Wrbas, K. T.
    Von See, C.
    Vach, K.
    Patzelt, S. B. M.
    [J]. EUROPEAN ENDODONTIC JOURNAL, 2019, 4 (01): : 28 - 32
  • [4] The accuracy of measurements of three-dimensional computed tomography reconstructions
    Covino, SW
    Mitnick, RJ
    Shprintzen, RJ
    Cisneros, GJ
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1996, 54 (08) : 982 - 990
  • [5] Three-dimensional image reconstruction with free open-source OsiriX software in video-assisted thoracoscopic lobectomy and segmentectomy
    Yao, Fei
    Wang, Jian
    Yao, Ju
    Hang, Fangrong
    Lei, Xu
    Cao, Yongke
    [J]. INTERNATIONAL JOURNAL OF SURGERY, 2017, 39 : 16 - 22
  • [6] On the Geometric Accuracy of RepRap Open-Source Three-Dimensional Printer
    Lanzotti, Antonio
    Del Giudice, Domenico Maria
    Lepore, Antonio
    Staiano, Gabriele
    Martorelli, Massimo
    [J]. JOURNAL OF MECHANICAL DESIGN, 2015, 137 (10)
  • [8] Accuracy of open-source software segmentation and paper-based printed three-dimensional models
    Szymor, Piotr
    Kozakiewicz, Marcin
    Olszewski, Raphael
    [J]. JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2016, 44 (02) : 202 - 209
  • [9] Three-dimensional accuracy of measurements made with software on cone-beam computed tomography images
    Lagravere, Manuel O.
    Carey, Jason
    Toogood, Roger W.
    Major, Paul W.
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2008, 134 (01) : 112 - 116
  • [10] Three-dimensional analysis of reconstructed skulls using three different open-source software versus commercial software
    Abdullah, Johari Yap
    Abdullah, Abdul Manaf
    Zaim, Syafawati
    Hadi, Helmi
    Husein, Adam
    Rajion, Zainul Ahmad
    Abdullah, Jafri Malin
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2024, 238 (01) : 55 - 62