Automated quantitative morphometry of vertebral heights on spinal radiographs: comparison of a clinical workflow tool with standard 6-point morphometry

被引:0
|
作者
Klaus Engelke
B. Stampa
P. Steiger
T. Fuerst
H. K. Genant
机构
[1] University of Erlangen,Institute of Medical Physics
[2] Bioclinica Inc.,Department of Medicine
[3] University Hospital,Department of Radiology
[4] University of Erlangen-Nürnberg,undefined
[5] PAREXEL International,undefined
[6] University of California,undefined
来源
Archives of Osteoporosis | 2019年 / 14卷
关键词
Active shape and appearance models; Automated quantitative morphometry; Vertebral fracture;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 10 条
  • [1] Automated quantitative morphometry of vertebral heights on spinal radiographs: comparison of a clinical workflow tool with standard 6-point morphometry
    Engelke, Klaus
    Stampa, B.
    Steiger, P.
    Fuerst, T.
    Genant, H. K.
    ARCHIVES OF OSTEOPOROSIS, 2019, 14 (01)
  • [2] Assessment of osteoporotic vertebral fractures using specialized workflow software for 6-point morphometry
    Guglielmi, Giuseppe
    Palmieri, Francesco
    Placentino, Maria Grazia
    D'Errico, Francesco
    Stoppino, Luca Pio
    EUROPEAN JOURNAL OF RADIOLOGY, 2009, 70 (01) : 142 - 148
  • [3] An automated algorithm for quantitative morphometry of thoracic and lumbar vertebral bodies in lateral radiographs
    Arakawa, Shoutaro
    Shinohara, Akira
    Arimura, Daigo
    Fukuda, Takeshi
    Takumi, Yukihiro
    Nishino, Kazuyoshi
    Saito, Mitsuru
    JBMR PLUS, 2025, 9 (04)
  • [4] QUANTITATIVE MORPHOMETRY ON SPINAL X-RAYS: INITIAL EVALUATION OF A NEW WORKFLOW TOOL FOR POINT PLACEMENT
    Engelke, K.
    Stampa, B.
    Timm, W.
    Steiger, P.
    Fuerst, T.
    Genant, H. K.
    OSTEOPOROSIS INTERNATIONAL, 2010, 21 : 227 - 227
  • [5] Reproducibility of a semi-automatic method for 6-point vertebral morphometry in a multi-centre trial
    Guglielmi, Giuseppe
    Stoppino, Luca Pio
    Placentino, Maria Grazia
    D'Errico, Francesco
    Palmieri, Francesco
    EUROPEAN JOURNAL OF RADIOLOGY, 2009, 69 (01) : 173 - 178
  • [6] QUANTITATIVE MORPHOMETRY ON SPINAL X-RAYS: INITIAL EVALUATION OF NEW WORKFLOW TOOL FOR MEASURING VERTEBRAL BODY HEIGHT IN FRACTURED VERTEBRAE
    Engelke, Klaus
    Stampa, Bernd
    Steiger, Peter
    Fuerst, Thomas
    Genant, Harry
    OSTEOPOROSIS INTERNATIONAL, 2011, 22 : 306 - 306
  • [7] QUANTITATIVE MORPHOMETRY: INTRA- AND INTER-READER REPRODUCIBILITY OF A NEW CLINICAL WORKFLOW TOOL
    Guglielmi, Giuseppe
    Nasuto, Michelangelo
    D'Errico, Francesco
    Placentino, Maria Grazia
    Di Chio, Francesca
    OSTEOPOROSIS INTERNATIONAL, 2013, 24 : S318 - S318
  • [8] QUANTITATIVE MORPHOMETRY ON SPINAL X-RAYS: LONG-TERM PRECISION OF A NEW WORKFLOW TOOL FOR MEASURING VERTEBRAL BODY HEIGHT IN NONFRACTURED VERTEBRAE
    Engelke, Klaus
    Stampa, Bernd
    Steiger, Peter
    Fuerst, Thomas
    Genant, Harry K.
    OSTEOPOROSIS INTERNATIONAL, 2012, 23 : S201 - S201
  • [9] Identification of prevalent vertebral fractures using CT lateral scout views: a comparison of semi-automated quantitative vertebral morphometry and radiologist semi-quantitative grading
    Kim, Y. M.
    Demissie, S.
    Genant, H. K.
    Cheng, X.
    Yu, W.
    Samelson, E. J.
    Kiel, D. P.
    Bouxsein, M. L.
    OSTEOPOROSIS INTERNATIONAL, 2012, 23 (03) : 1007 - 1016
  • [10] Identification of prevalent vertebral fractures using CT lateral scout views: a comparison of semi-automated quantitative vertebral morphometry and radiologist semi-quantitative grading
    Y. M. Kim
    S. Demissie
    H. K. Genant
    X. Cheng
    W. Yu
    E. J. Samelson
    D. P. Kiel
    M. L. Bouxsein
    Osteoporosis International, 2012, 23 : 1007 - 1016