Design of the cold atom PHARAO space clock and initial test results

被引:0
|
作者
Ph. Laurent
M. Abgrall
Ch. Jentsch
P. Lemonde
G. Santarelli
A. Clairon
I. Maksimovic
S. Bize
Ch. Salomon
D. Blonde
J.F. Vega
O. Grosjean
F. Picard
M. Saccoccio
M. Chaubet
N. Ladiette
L. Guillet
I. Zenone
Ch. Delaroche
Ch. Sirmain
机构
[1] SYRTE,
[2] CNES,undefined
[3] Laboratoire Kastler Brossel,undefined
[4] Prologue BP 27-04,undefined
来源
Applied Physics B | 2006年 / 84卷
关键词
Cesium; International Space Station; Cold Atom; Capture Zone; Microwave Source;
D O I
暂无
中图分类号
学科分类号
摘要
In this paper we describe the cold atom clock PHARAO, designed for microgravity operation. All elements of the PHARAO engineering model have been manufactured and delivered to CNES, the French space agency. We present the clock design, its main characteristics, and initial science operation. PHARAO is one of the main components of the Atomic Clock Ensemble in Space payload that is scheduled to fly on board the International Space Station in 2010.
引用
收藏
页码:683 / 690
页数:7
相关论文
共 50 条
  • [1] Design of the cold atom PHARAO space clock and initial test results
    Laurent, Ph.
    Abgrall, M.
    Jentsch, Ch.
    Lemonde, P.
    Santarelli, G.
    Clairon, A.
    Maksimovic, I.
    Bize, S.
    Salomon, Ch.
    Blonde, D.
    Vega, J. F.
    Grosjean, O.
    Picard, F.
    Saccoccio, M.
    Chaubet, M.
    Ladiette, N.
    Guillet, L.
    Zenone, I.
    Delaroche, Ch.
    Sirmain, Ch.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2006, 84 (04): : 683 - 690
  • [2] Magnetic shielding of the cold atom space clock PHARAO
    Moric, Igor
    Laurent, Philippe
    Chatard, Philippe
    de Graeve, Charles-Marie
    Thomin, Stephane
    Christophe, Vincent
    Grosjean, Olivier
    ACTA ASTRONAUTICA, 2014, 102 : 287 - 294
  • [3] An advanced technology for a new generation of cold atom space clock (PHARAO)
    Gonzalez, F
    Granier, JP
    Laurent, P
    ACTA ASTRONAUTICA, 2000, 47 (2-9) : 335 - 345
  • [4] Initial Tests of a Rubidium Space Cold Atom Clock
    李琳
    屈求智
    汪斌
    李唐
    赵剑波
    吉经纬
    任伟
    赵鑫
    叶美凤
    姚媛媛
    吕德胜
    刘亮
    Chinese Physics Letters, 2016, (06) : 21 - 24
  • [5] Initial Tests of a Rubidium Space Cold Atom Clock
    李琳
    屈求智
    汪斌
    李唐
    赵剑波
    吉经纬
    任伟
    赵鑫
    叶美凤
    姚媛媛
    吕德胜
    刘亮
    Chinese Physics Letters, 2016, 33 (06) : 21 - 24
  • [6] Initial Tests of a Rubidium Space Cold Atom Clock
    Li, Lin
    Qu, Qiu-Zhi
    Wang, Bin
    Li, Tang
    Zhao, Jian-Bo
    Ji, Jing-Wei
    Ren, Wei
    Zhao, Xin
    Ye, Mei-Feng
    Yao, Yuan-Yuan
    Lu, De-Sheng
    Liu, Liang
    CHINESE PHYSICS LETTERS, 2016, 33 (06)
  • [7] Status of the Flight Model of the Cold Atoms Space Clock PHARAO
    Moric, Igor
    Laurent, Philippe
    2013 JOINT EUROPEAN FREQUENCY AND TIME FORUM & INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM (EFTF/IFC), 2013, : 967 - 972
  • [8] The PHARAO space clock: Results on the ground operation of the engineering model
    Laurent, Philippe
    Jentsch, Chistian
    Clairon, Andre
    Lemonde, Pierre
    Santarelli, Giorgio
    Abgrall, Michel
    Sirmain, Christian
    Picard, Frederic
    Delaroche, Christophe
    Grosjean, Olivier
    Blonde, Didier
    Chaubet, Michel
    Guillemot, Philippe
    Vega, Jean Francois
    Zenone, Isabelle
    Ladiette, Nadine
    Salomon, Christophe
    PROCEEDINGS OF THE 2007 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM-JOINTLY WITH THE 21ST EUROPEAN FREQUENCY AND TIME FORUM, VOLS 1-4, 2007, : 1106 - +
  • [9] The PHARAO project: Towards a space clock using cold Cs atoms
    Simon, E
    Laurent, P
    Santarelli, G
    Clairon, A
    Lemonde, P
    Salomon, C
    Dimarcq, N
    Petit, P
    Audoin, C
    Gonzalez, F
    Changeart, FJ
    ACTA ASTRONAUTICA, 1997, 40 (12) : 837 - 841
  • [10] Test of a space cold atom clock prototype in absence of gravity
    Lemonde, P
    Laurent, P
    Simon, E
    Santarelli, G
    Clairon, A
    Salomon, C
    Dimarcq, N
    Petit, P
    1998 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 1998, : 124 - 125