Optimal Multivariate Gaussian Fitting with Applications to PSF Modeling in Two-Photon Microscopy Imaging

被引:0
|
作者
Emilie Chouzenoux
Tim Tsz-Kit Lau
Claire Lefort
Jean-Christophe Pesquet
机构
[1] Université Paris-Saclay,Center for Visual Computing, CentraleSupélec, INRIA Saclay
[2] Université Paris-Est Marne-la-Vallée,Laboratoire d’Informatique Gaspard Monge, UMR CNRS 8049
[3] Northwestern University,Department of Statistics
[4] Université de Limoges,XLIM Research Institute, UMR CNRS 7252
关键词
Gaussian fitting; Kullback–Leibler divergence; Alternating minimization; Proximal methods; PSF identification; Two-photon fluorescence microscopy;
D O I
暂无
中图分类号
学科分类号
摘要
Fitting Gaussian functions to empirical data is a crucial task in a variety of scientific applications, especially in image processing. However, most of the existing approaches for performing such fitting are restricted to two dimensions and they cannot be easily extended to higher dimensions. Moreover, they are usually based on alternating minimization schemes which benefit from few theoretical guarantees in the underlying nonconvex setting. In this paper, we provide a novel variational formulation of the multivariate Gaussian fitting problem, which is applicable to any dimension and accounts for possible nonzero background and noise in the input data. The block multiconvexity of our objective function leads us to propose a proximal alternating method to minimize it in order to estimate the Gaussian shape parameters. The resulting FIGARO algorithm is shown to converge to a critical point under mild assumptions. The algorithm shows a good robustness when tested on synthetic datasets. To demonstrate the versatility of FIGARO, we also illustrate its excellent performance in the fitting of the point spread functions of experimental raw data from a two-photon fluorescence microscope.
引用
收藏
页码:1037 / 1050
页数:13
相关论文
共 50 条
  • [1] Optimal Multivariate Gaussian Fitting with Applications to PSF Modeling in Two-Photon Microscopy Imaging
    Chouzenoux, Emilie
    Lau, Tim Tsz-Kit
    Lefort, Claire
    Pesquet, Jean-Christophe
    JOURNAL OF MATHEMATICAL IMAGING AND VISION, 2019, 61 (07) : 1037 - 1050
  • [2] OPTIMAL MULTIVARIATE GAUSSIAN FITTING FOR PSF MODELING IN TWO-PHOTON MICROSCOPY
    Lau, Tim Tsz-Kit
    Chouzenoux, Emilie
    Lefort, Claire
    Pesquet, Jean-Christophe
    2018 IEEE 15TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2018), 2018, : 484 - 488
  • [3] Two-photon PSF-engineered image scanning microscopy
    Tzang, Omer
    Feldkhun, Dan
    Agrawal, Anurag
    Jesacher, Alexander
    Piestun, Rafael
    OPTICS LETTERS, 2019, 44 (04) : 895 - 898
  • [4] Applications of two-photon fluorescence microscopy in deep tissue imaging
    Dong, CY
    Yu, B
    Hsu, L
    Kaplan, P
    Blankschstein, D
    Langer, R
    So, PTC
    OPTICAL SENSING, IMAGING, AND MANIPULATION FOR BIOLOGICAL AND BIOMEDICAL APPLICATIONS, 2000, 4082 : 105 - 114
  • [5] Applications of two-photon microscopy in the neurosciences
    Cruz, HG
    Lüscher, C
    FRONTIERS IN BIOSCIENCE-LANDMARK, 2005, 10 : 2263 - 2278
  • [6] Two-photon microscopy using hollow Gaussian beam
    Ul Alam, Sabir
    Soni, Niraj Kumar
    Ren, Yu-Xuan
    He, Hongsen
    Tsia, Kevin K.
    Wong, Kenneth K. Y.
    2020 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2020,
  • [7] Imaging of Protein Crystals with Two-Photon Microscopy
    Padayatti, Pius
    Palczewska, Grazyna
    Sun, Wenyu
    Palczewski, Krzysztof
    Salom, David
    BIOCHEMISTRY, 2012, 51 (08) : 1625 - 1637
  • [8] Two-photon microscopy for Imaging inside arteries
    van Zandvoort, MAMJ
    Slaaf, DW
    JOURNAL OF VASCULAR RESEARCH, 2004, 41 (05) : 451 - 451
  • [9] Cardiovascular Imaging Using Two-Photon Microscopy
    Scherschel, John A.
    Rubart, Michael
    MICROSCOPY AND MICROANALYSIS, 2008, 14 (06) : 492 - 506
  • [10] Imaging melanin by two-photon absorption microscopy
    Ye, Tong
    Yurtsever, Gunay
    Fischer, Martin
    Simon, John D.
    Warren, Warren S.
    MULTIPHOTON MICROSCOPY IN THE BIOMEDICAL SCIENCES VI, 2006, 6089