Radiation exposure to the patient during closed intramedullary nailing [Strahlenexposition des patienten durch intraoperative bildgebung bei marknagelosteosynthesen]

被引:0
|
作者
Suhm N. [1 ]
Jacob A.L. [2 ]
Zuna I. [3 ]
Roser H.W. [3 ]
Regazzoni P. [1 ]
Messmer P. [4 ]
机构
[1] Departement Chirurgie, Kantonsspital Basel, Universitätskliniken
[2] Departement Radiologie, Kantonsspital Basel, Universitätskliniken
[3] Forschungsschwerpunkt Radiologische Diagnostik und Therapie, Deutsches Krebsforschungszentrum, Heidelberg
[4] Abteilung Radiologische Physik, Kantonsspital Basel, Universitätskliniken
来源
Der Radiologe | 2001年 / 41卷 / 1期
关键词
Closed intramedullary nailing; Effective radiation dose; Fluoroscopic time; Radiation exposure to the patient;
D O I
10.1007/s001170050932
中图分类号
学科分类号
摘要
Material and Method. 39 patients with pertrochanteric femur fracture (n=32) or lower leg fracture (n=7) were treated with closed intramedullary nailing. The related radiation exposure of the patients was calculated. Results. Osteosynthesis of pertrochanteric fractures took less fluoroscopic time than osteosynthesis of lower leg fractures. The effective dose was 14 mSv for nailing osteosynthesis of proximal pertrochanteric fractures and less than 0.1 mSv for osteosynthesis of distal lower leg fractures. Conclusion. Radiation exposure of the patient due to intraoperative fluoroscopic imaging during osteosynthesis can be estimated based on the data given above. Intraoperative observations imply, consequent application of radiation protection by the orthopaedic surgeons may reduce intraoperative radiation exposure even more.
引用
收藏
页码:91 / 94
页数:3
相关论文
共 7 条
  • [1] Radiation exposure to the patient during closed intramedullary nailing
    Suhm, N
    Jacob, AL
    Zuna, I
    Roser, HW
    Regazzoni, P
    Messmer, P
    RADIOLOGE, 2001, 41 (01): : 91 - 94
  • [2] RADIATION EXPOSURE TO THE SURGEON DURING CLOSED INTERLOCKING INTRAMEDULLARY NAILING
    LEVIN, PE
    SCHOEN, RW
    BROWNER, BD
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1987, 69A (05): : 761 - 766
  • [3] Intraoperative radiation exposure in elastic stable intramedullary nailing (ESIN) during the growth period. Observations in 162 long bone shaft fractures
    Kraus, R.
    Meyer, C.
    Heiss, C.
    Stahl, J. -P.
    Schnettler, R.
    UNFALLCHIRURG, 2007, 110 (01): : 28 - 32
  • [4] Functional Changes of the Gustatory Organ Caused by Local Radiation Exposure during Radiotherapy of the Head-and-Neck RegionFunktionsveränderungen des Geschmacksorgans durch lokale Strahlenexposition bei Strahlentherapie der Kopf-Hals-Region
    Friedrich Kamprad
    Dörthe Ranft
    Anette Weber
    Guido Hildebrandt
    Strahlentherapie und Onkologie, 2008, 184 (3) : 157 - 162
  • [5] Radiation Exposure to the Surgeon, Surgical Assistant, and Scrub Nurse During Closed Intramedullary Nailing of Long Bones-Does It Vary Depending on the Experience of the Surgeon?
    Patra, Sudipta K.
    Shetty, Ajoy P.
    Jayaramaraju, Dheenadhayalan
    Rajasekaran, Shanmuganathan
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2019, 33 (02) : E52 - E57
  • [6] Intraoperative Durchleuchtungszeiten bei elastisch stabiler intramedullärer Nagelung (ESIN) im WachstumsalterBeobachtungen an 162 Schaftfrakturen langer RöhrenknochenIntraoperative radiation exposure in elastic stable intramedullary nailing (ESIN) during the growth periodObservations in 162 long bone shaft fractures
    R. Kraus
    C. Meyer
    C. Heiss
    J.-P. Stahl
    R. Schnettler
    Der Unfallchirurg, 2007, 110 (1): : 28 - 32
  • [7] Operator radiation exposure during transradial coronary angiography: Effect of single vs. double catheters; [Strahlenexposition des Untersuchers bei transradialer Koronarangiographie: Einfluss von Einzel- vs. Doppelkatheter]
    Tarighatnia A.
    Pourafkari L.
    Farajollahi A.
    Mohammadalian A.H.
    Ghojazadeh M.
    Nader N.D.
    Herz, 2018, 43 (6) : 535 - 542