Estimation of the enantiomeric purity of chiral biologically active compounds, as well as the determination of particular optical isomers, is very important for the control of medicines, food, and biological fluids. The main approaches to the development of electrochemical enantioselective sensors with the amperometric detection of the signal are considered in this review. Examples of the use of biochemical and supramolecular receptors providing enantiomer recognition and techniques of their inclusion into the corresponding sensors are given. The main characteristics of enantioselective sensors for the determination of optically active medicines, organic acids, aminoacids, carbohydrates, alcohols, and other biologically important compounds are considered.
引用
收藏
页码:2 / 12
页数:10
相关论文
共 50 条
  • [1] Chemically modified electrodes with amperometric response in enantioselective analysis
    Budnikov, G. K.
    Evtyugin, G. A.
    Budnikova, Yu. G.
    Al'fonsov, V. A.
    [J]. JOURNAL OF ANALYTICAL CHEMISTRY, 2008, 63 (01) : 2 - 12
  • [2] Chemically modified electrodes with amperometric response in enantioselective analysis
    Kazan State University, ul. Kremlevskaya 18, Kazan, 420008 Tatarstan, Russia
    不详
    [J]. J. Anal. Chem., 2008, 1 (2-12):
  • [3] Chemically modified electrodes as amperometric sensors in electroanalysis
    Budnikov, G.Κ.
    Labuda, J.
    [J]. Russian Chemical Reviews, 1992, 61 (08) : 816 - 829
  • [4] Modelling amperometric biosensors based on chemically modified electrodes
    Baronas, Romas
    Kulys, Juozas
    [J]. SENSORS, 2008, 8 (08) : 4800 - 4820
  • [5] Effect of surfactants on the signal of chemically modified amperometric electrodes
    Technical Univ of Budapest, Budapest, Hungary
    [J]. Sens Actuators, B Chem, 1 -3 pt 1 (323-327):
  • [6] EFFECT OF SURFACTANTS ON THE SIGNAL OF CHEMICALLY-MODIFIED AMPEROMETRIC ELECTRODES
    NAGY, G
    KAPUI, I
    GORTON, L
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1995, 24 (1-3) : 323 - 327
  • [7] Analytical strategies for amperometric biosensors based on chemically modified electrodes
    Lorenzo, E
    Pariente, F
    Hernandez, L
    Tobalina, F
    Darder, M
    Wu, Q
    Maskus, M
    Abruna, HD
    [J]. BIOSENSORS & BIOELECTRONICS, 1998, 13 (3-4): : 319 - 332
  • [8] Analytical strategies for amperometric biosensors based on chemically modified electrodes
    Department of Analytical Chemistry, Universidad Autonoma de Madrid, 28049 Madrid, Spain
    不详
    [J]. Biosens. Bioelectron., 3-4 (319-332):
  • [9] The potentiometric response of chemically modified electrodes
    Lindino, CA
    Bulhoes, LOS
    [J]. ANALYTICA CHIMICA ACTA, 1996, 334 (03) : 317 - 322
  • [10] STRATEGIES FOR ANALYSIS WITH CHEMICALLY MODIFIED ELECTRODES
    ABRUNA, HD
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1988, 195 : 118 - ANYL