Application of the vector-pulse method to starting an alternating-current motor

被引:13
|
作者
Baskov S.N. [1 ]
Radionov A.A. [1 ]
Svyatykh A.B. [1 ]
机构
[1] South Ural State University, Chelyabinsk
关键词
asynchronous motor; experiment; starting method; synchronous motor; vector-impulse control;
D O I
10.3103/S1068371213100027
中图分类号
学科分类号
摘要
A soft-start method for induction and synchronous motors is considered. The method is based on pulse switching of the motor stator to the supply network at the moments at which the stator- and rotor-flux linkage vectors produce positive electromagnetic torque. A wiring diagram of the experimental soft-start device, its operation algorithm, and experimental outcomes are presented. © 2013 Allerton Press, Inc.
引用
收藏
页码:591 / 594
页数:3
相关论文