Peak velocity estimation in aortic stenosis patients using a fast three-directional two-dimensional phase contrast technique in a single breath-hold: comparison to unidirectional phase contrast MRI and transthoracic echocardiography

被引:0
|
作者
Juliana Serafim da Silveira
Matthew E Smyke
Rizwan Ahmad
Ning Jin
Debbie Scandling
Jennifer A Dickerson
Carlos E Rochitte
Subha V Raman
Orlando P Simonetti
机构
[1] Department of Internal Medicine/Division of Cardiovascular Medicine,Dorothy M. Davis Heart and Lung Research Institute
[2] OSU,Department of Medicine/Cardiology
[3] The Ohio State University,Department of Radiology
[4] Siemens Healthcare,undefined
[5] InCor Heart Institute,undefined
[6] The Ohio State University,undefined
关键词
Stroke Volume; Peak Velocity; Aortic Valve Stenosis; Aortic Valve Stenosis Severity; Phase Contrast Technique;
D O I
10.1186/1532-429X-18-S1-P335
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 9 条
  • [1] Aortic Stenosis assessment with a 3-directional phase contrast magnetic resonance technique. Comparison to transthoracic echocardiography
    Juliana Serafim da Silveira
    Matthew Smyke
    Ning Jin
    Rizwan Ahmad
    Lua Jafari
    Debbie Scandling
    Jennifer A Dickerson
    Subha V Raman
    Orlando P Simonetti
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [2] MR angiography of the renal artery: comparison of breath-hold two-dimensional phase-contrast cine technique with the phased-array coil and breath-hold two-dimensional time-of-flight technique with the body coil
    Masui, T
    Takehara, Y
    Igarashi, T
    Ichijo, K
    Takahashi, M
    Kaneko, M
    Nozaki, A
    EUROPEAN JOURNAL OF RADIOLOGY, 1997, 25 (01) : 62 - 66
  • [3] 1065 Three-directional myocardial motion in patients with univentricular hearts using velocity-encoded phase contrast MRI
    Christina E Saikus
    Kartik Sundareswaran
    Resmi Krishnankutty
    John N Oshinski
    Mark A Fogel
    Ajit P Yoganathan
    Journal of Cardiovascular Magnetic Resonance, 10 (Suppl 1)
  • [4] Comparison of cardiac stroke volume measurement determined using stereological analysis of breath-hold cine MRI and phase contrast velocity mapping
    Graves, MJ
    Dommett, DMF
    BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (872): : 825 - 832
  • [5] Highly accelerated phase-contrast MRI-based multi-directional flow imaging for peak velocity estimation in aortic stenosis patients.
    Juliana Serafim da Silveira
    Adam V Rich
    Yingmin Liu
    Matthew Smyke
    Ning Jin
    Debbie Scandling
    Jennifer A Dickerson
    Carlos E Rochitte
    Subha V Raman
    Lee C Potter
    Rizwan Ahmad
    Orlando P Simonetti
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [6] MR Imaging of the chest using a contrast-enhanced breath-hold modified three-dimensional gradient-echo technique: Comparison with two-dimensional gradient-echo technique and multidetector CT
    Karabulut, N
    Martin, DR
    Yang, M
    Tallaksen, RJ
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (05) : 1225 - 1233
  • [7] Quantification of peak blood flow velocity at the cardiac valve and great thoracic vessels by four- dimensional flow and two-dimensional phase- contrast MRI compared with echocardiography: a systematic review and meta-analysis
    Xu, K.
    Wang, X. D.
    Yang, Z. G.
    Xu, H. Y.
    Xu, R.
    Xie, L. J.
    Wen, L. Y.
    Fu, H.
    Yan, W. F.
    Guo, Y. K.
    CLINICAL RADIOLOGY, 2021, 76 (11) : 863.e1 - 863.e10
  • [8] Magnetic resonance cholangiopancreatography: Comparison of respiratory-triggered three-dimensional fast-recovery fast spin-echo with parallel imaging technique and breath-hold half-Fourier two-dimensional single-shot fast spin-echo technique
    Masui T.
    Katayama M.
    Kobayashi S.
    Nozaki A.
    Sugimura M.
    Ikeda M.
    Sakahara H.
    Radiation Medicine, 2006, 24 (3): : 202 - 209
  • [9] Re: Quantification of peak blood flow velocity at the cardiac valve and great thoracic vessels by four-dimensional flow and two-dimensional phase-contrast MRI compared with echocardiography: a systematic review and meta-analysis
    Yue, S.
    Wang, J.
    CLINICAL RADIOLOGY, 2022, 77 (04) : 314 - 315