Improving the power of objective response detection of evoked responses in noise by using average and product of magnitude-squared coherence of two different signals

被引:0
|
作者
Tiago Zanotelli
Antonio Mauricio Ferreira Leite Miranda de Sá
Eduardo Mazoni Andrade Marçal Mendes
Leonardo Bonato Felix
机构
[1] Federal University of Minas Gerais,Graduate Program in Electrical Engineering
[2] Federal Institute of Espírito Santo,Department of Electrical Engineering
[3] Federal University of Viçosa,Department of Electrical Engineering
[4] Federal University of Rio de Janeiro,Biomedical Engineering Program/COPPE
关键词
Detection; Evoked responses; Magnitude-squared coherence (MSC); Average coherence; Product coherence;
D O I
暂无
中图分类号
学科分类号
摘要
Objective response detection (ORD) techniques such as the magnitude-squared coherence (MSC) are mathematical methods tailored to detect potentials evoked by an external periodic stimulation. The performance of the MSC is directly proportional to the signal-to-noise ratio (SNR) of the recorded signal and the time spent for collecting data. An alternative to increasing the performance of detection techniques without increasing data recording time is to use the information from more than one signal simultaneously. In this context, this work proposes two new detection techniques based on the average and on the product of MSCs of two different signals. The critical values and detection probabilities were obtained theoretically and using a Monte Carlo simulation. The performances of the new detectors were evaluated using synthetic data and electroencephalogram (EEG) signals during photo and auditory stimulation. For the synthetic signals, the two proposed detectors exhibited a higher detection rate when compared to the rate of the traditional MSC technique. When applied to EEG signals, these detectors resulted in an increase of the mean detection rate in relation to MSC for visual and auditory stimulation of at least 25% and 13.21%, respectively. The proposed detectors may be considered as promising tools for clinical applications.
引用
收藏
页码:2203 / 2214
页数:11
相关论文
共 5 条
  • [1] Improving the power of objective response detection of evoked responses in noise by using average and product of magnitude-squared coherence of two different signals
    Zanotelli, Tiago
    Leite Miranda de Sa, Antonio Mauricio Ferreira
    Andrade Marcal Mendes, Eduardo Mazoni
    Felix, Leonardo Bonato
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2019, 57 (10) : 2203 - 2214
  • [2] OBJECTIVE DETECTION OF 40-HZ AUDITORY-EVOKED POTENTIALS - PHASE COHERENCE VS MAGNITUDE-SQUARED COHERENCE
    DOBIE, RA
    WILSON, MJ
    [J]. ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1994, 92 (05): : 405 - 413
  • [3] Estimation of Magnitude-Squared Coherence Using Least Square Method and Phase Compensation: A New Objective Response Detector
    Antunes, F.
    Felix, L. B.
    [J]. XXVII BRAZILIAN CONGRESS ON BIOMEDICAL ENGINEERING, CBEB 2020, 2022, : 1547 - 1552
  • [4] Improving the detection of auditory steady-state responses near 80 Hz using multiple magnitude-squared coherence and multichannel electroencephalogram
    da Silva Eloi, Brenda Ferreira
    Antunes, Felipe
    Felix, Leonardo Bonato
    [J]. BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2018, 42 : 158 - 161
  • [5] Multi-harmonic Analysis Using Magnitude-Squared Coherence and Its Application to Detection of Auditory Steady-State Responses
    Aureliano Netto, Abdon Francisco
    Zanotelli, Tiago
    Felix, Leonardo Bonato
    [J]. COMPUTATIONAL NEUROSCIENCE, 2019, 1068 : 121 - 129