Combined imaging of molecular function and morphology with PET/CT and SPECT/CT: Image fusion and motion correction

被引:0
|
作者
Klaus P. Schäfers
Lars Stegger
机构
[1] University of Münster,Dept. of Nuclear Medicine
来源
关键词
image fusion; motion correction;
D O I
暂无
中图分类号
学科分类号
摘要
Imaging of the cardiovascular system with a combination of positron emission tomography (PET) and computer tomography (CT) or with a combination of single-photon emission computerized tomography (SPECT) and CT holds great promise for the future. Owing to the movement of the heart and the great vessels due to heart contraction and respiration this is, however, not straightforward. This article provides an overview over the principles of combined PET/CT or SPECT/CT imaging. It points out technical challenges inherent in imaging of cardiovascular system and presents possible solutions that allow for optimal fusion and motion correction of the combined molecular, functional and morphological image data.
引用
收藏
页码:191 / 199
页数:8
相关论文
共 50 条
  • [1] Combined imaging of molecular function and morphology with PET/CT and SPECT/CT:: Image fusion and motion correction
    Schaefers, Klaus P.
    Stegger, Lars
    BASIC RESEARCH IN CARDIOLOGY, 2008, 103 (02) : 191 - 199
  • [2] Morphology supporting function: attenuation correction for SPECT/CT, PET/CT, and PET/MR imaging
    Lee, Tzu C.
    Alessio, Adam M.
    Miyaoka, Robert M.
    Kinahan, Paul E.
    QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 60 (01): : 25 - 39
  • [3] COMBINED IMAGING MODALITIES: PET/CT AND SPECT/CT
    Maurer, Alan H.
    HEALTH PHYSICS, 2008, 95 (05): : 571 - 576
  • [4] Combined SPECT/CT and PET/CT for breast imaging
    Russo, Paolo
    Larobina, Michele
    Di Lillo, Francesca
    Del Vecchio, Silvana
    Mettivier, Giovanni
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 809 : 58 - 66
  • [5] Motion estimation and correction in SPECT, PET and CT
    Kyme, Andre Z.
    Fulton, Roger R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (18):
  • [6] Rigid motion correction of PET and CT for PET/CT brain imaging
    Bickell, Matthew
    Kim, Jung-Ha
    Rezaei, Ahmadreza
    Nuyts, Johan
    Fulton, Roger
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [7] PET/CT attenuation correction and image fusion
    Carney, J
    MEDICAL PHYSICS, 2005, 32 (06) : 2116 - 2116
  • [8] PET/CT attenuation correction and image fusion
    Patton, J.
    MEDICAL PHYSICS, 2006, 33 (06) : 2178 - 2178
  • [9] PET/CT attenuation correction and image fusion
    Carney, J
    MEDICAL PHYSICS, 2004, 31 (06) : 1803 - 1803
  • [10] Motion correction in dynamic PET/CT imaging
    Feeley, Christina
    Moore, Stephen
    Pande, Reena
    Park, Mi-Ae
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50