In-Situ Study on Nondestructive Detection of Pile Integrity Using Lateral Excitation

被引:0
|
作者
Wang Xin-quan
Cui Yun-liang
Qi Chang-guang
Zhang Shi-min
机构
[1] Zhejiang University City College,Faculty of Architecture, Civil Engineering and Environment
[2] Ningbo University,undefined
关键词
D O I
暂无
中图分类号
学科分类号
摘要
A new detection method using lateral excitation to test pile integrity is proposed. Concrete piles were subjected to lateral excitation, which produced transverse waves. These waves were processed with the Hilbert-Huang Transform (HHT), and the results were compared with those of a nondestructive testing method based on vertical excitation. The locations of the defects in the pile body detected by the lateral excitation method agree well with those derived by the vertical excitation method, which indicates that HHT analysis of the lateral acceleration wave signal obtained by HHT can detect defects in a pile body. Thus, lateral excitation technology can be applied in integrity assessments of pile foundations that have constraints or structural limits on their top.
引用
收藏
页码:398 / 404
页数:6
相关论文
共 50 条
  • [1] In-Situ Study on Nondestructive Detection of Pile Integrity Using Lateral Excitation
    Wang Xin-quan
    Cui Yun-liang
    Qi Chang-guang
    Zhang Shi-min
    SOIL MECHANICS AND FOUNDATION ENGINEERING, 2017, 53 (06) : 398 - 404
  • [2] In-Situ Test Study on Lateral Friction of Screw Pile Composite Foundation of High Speed Railway
    Ye Y.
    Cai D.
    Chen X.
    Yang Y.
    Chen F.
    Zhongguo Tiedao Kexue/China Railway Science, 2020, 41 (02): : 1 - 10
  • [3] NONDESTRUCTIVE IN-SITU RAMAN-STUDY OF ARTISTIC GLASSES
    BERTOLUZZA, A
    CACCIARI, S
    CRISTINI, G
    TINTI, A
    JOURNAL OF RAMAN SPECTROSCOPY, 1995, 26 (8-9) : 751 - 755
  • [4] A case study of timber pile in-situ soil reinforcement
    Kuo, CL
    Heung, W
    Tejidor, FJ
    Roberts, J
    SOIL IMPROVEMENT FOR BIG DIGS, 1998, (81): : 177 - 189
  • [5] Study on defect detection of extended pile shaft under lateral low-strain integrity test
    Zhao S.
    Wu J.-T.
    Qiu X.-C.
    Wang K.-H.
    Tu Y.
    Zhejiang Daxue Xuebao (Gongxue Ban)/Journal of Zhejiang University (Engineering Science), 2021, 55 (10): : 1867 - 1876and1902
  • [6] Nondestructive integrity evaluation of PC pile using Wigner-Ville distribution method
    Ni, Sheng-Huoo
    Lo, Kuo-Feng
    Huang, Yan-Hong
    MODERN PHYSICS LETTERS B, 2008, 22 (11): : 959 - 964
  • [7] Using nondestructive in-situ measurements to ensure lyophilized product stability
    Kenvin, Jeff
    Pharmaceutical Technology, 2018, 42 (10)
  • [8] Using Nondestructive in-situ Measurements to Ensure Lyophilized Product Stability
    Kenvin, Jeff
    BIOPHARM INTERNATIONAL, 2018, 31 (10) : 24 - +
  • [9] Study on lateral ReRAM by the use of in-situ TEM
    Yonesaka, R.
    Muto, S.
    Tsurumaki-Fukuchi, A.
    Arita, M.
    Takahashi, Y.
    2016 IEEE 16TH INTERNATIONAL CONFERENCE ON NANOTECHNOLOGY (IEEE-NANO), 2016, : 790 - 791
  • [10] In-situ lateral loading tests on two piles group of steel pipe pile with wings
    Kobayashi T.
    Nakano T.
    Kashiwa H.
    Miyamoto Y.
    1600, Architectural Institute of Japan (26): : 85 - 90