Evaluation of different near-infrared spectroscopy technologies for assessment of tissue oxygen saturation during a vascular occlusion test

被引:0
|
作者
Kevin Steenhaut
Koen Lapage
Thierry Bové
Stefan De Hert
Annelies Moerman
机构
[1] Ghent University Hospital,Department of Anesthesiology
[2] Ghent University Hospital,Department of Cardiac Surgery
关键词
Near-infrared spectroscopy; Tissue oxygen saturation; Vascular occlusion test;
D O I
暂无
中图分类号
学科分类号
摘要
An increasing number of NIRS devices are used to provide measurements of peripheral tissue oxygen saturation (StO2). The aim of the present study is to test the hypothesis that despite technological differences between devices, similar trend values will be obtained during a vascular occlusion test. The devices compared are NIRO-200NX, which measures StO2 and oxyhemoglobin by spatially resolved spectroscopy and the Beer–Lambert law, respectively, and INVOS 5100C and Foresight Elite, which both measure StO2 with the Beer–Lambert law, enhanced with the spatial resolution technique. Forty consenting adults scheduled for CABG surgery were recruited. The respective sensors of the three NIRS devices were applied over the brachioradial muscle. Before induction of anesthesia, 3 min of ischemia were induced by inflating a blood pressure cuff at the upper arm, whereafter cuff pressure was rapidly released. Tissue oxygenation measurements included baseline, minimum and maximum values, desaturation and resaturation slopes, and rise time. Comparisons between devices were performed with the Kruskal–Wallis test with post hoc Mann–Whitney pairwise comparisons. Agreement was evaluated using Bland–Altman plots. Oxyhemoglobin measured with NIRO responded faster than the other NIRS technologies to changes in peripheral tissue oxygenation (20 vs. 27–40 s, p ≤ 0.01). When comparing INVOS with Foresight, oxygenation changes were prompter (upslope 311 [92–523]%/min vs. 114[65–199]%/min, p ≤ 0.01) and more pronounced (minimum value 36 [21–48] vs. 45 [40–51]%, p ≤ 0.01) with INVOS. Significant differences in tissue oxygen saturation measurements were observed, both within the same device as between different devices using the same measurement technology.
引用
收藏
页码:1151 / 1158
页数:7
相关论文
共 50 条
  • [1] Evaluation of different near-infrared spectroscopy technologies for assessment of tissue oxygen saturation during a vascular occlusion test
    Steenhaut, Kevin
    Lapage, Koen
    Bove, Thierry
    De Hert, Stefan
    Moerman, Annelies
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2017, 31 (06) : 1151 - 1158
  • [2] Assessment of tissue oxygen saturation during a vascular occlusion test using near-infrared spectroscopy: the role of probe spacing and measurement site studied in healthy volunteers
    Bezemer, Rick
    Lima, Alexandre
    Myers, Dean
    Klijn, Eva
    Heger, Michal
    Goedhart, Peter T.
    Bakker, Jan
    Ince, Can
    [J]. CRITICAL CARE, 2009, 13 : S4
  • [3] Assessment of tissue oxygen saturation during a vascular occlusion test using near-infrared spectroscopy: the role of probe spacing and measurement site studied in healthy volunteers
    Rick Bezemer
    Alexandre Lima
    Dean Myers
    Eva Klijn
    Michal Heger
    Peter T Goedhart
    Jan Bakker
    Can Ince
    [J]. Critical Care, 13
  • [4] Assessment of tissue oxygen saturation during a vascular occlusion test using near-infrared spectroscopy: role of the probe spacing and measurement site studied in healthy volunteers
    R Bezemer
    A Lima
    E Klijn
    J Bakker
    C Ince
    [J]. Critical Care, 13 (Suppl 1):
  • [5] Evaluation of Different Near-Infrared Spectroscopy Devices for Assessing Tissue Oxygenation with a Vascular Occlusion Test in Healthy Volunteers
    Chung, Jaeyeon
    Ji, Sang-Hwan
    Jang, Young-Eun
    Kim, Eun-Hee
    Lee, Ji-Hyun
    Kim, Jin-Tae
    Kim, Hee-Soo
    [J]. JOURNAL OF VASCULAR RESEARCH, 2020, 57 (06) : 341 - 347
  • [6] Near-Infrared Spectroscopy Assessment of Tissue Saturation of Oxygen in Torsed and Healthy Testes
    Schoenfeld, E. M.
    Coute, R.
    Blank, F. S.
    Capraro, G.
    [J]. ANNALS OF EMERGENCY MEDICINE, 2012, 60 (04) : S59 - S60
  • [7] Near-infrared Spectroscopy Assessment of Tissue Saturation of Oxygen in Torsed and Healthy Testes
    Schoenfeld, Elizabeth M.
    Capraro, Geoffrey A.
    Blank, Fidela S. J.
    Coute, Ryan A.
    Visintainer, Paul F.
    [J]. ACADEMIC EMERGENCY MEDICINE, 2013, 20 (10) : 1080 - 1083
  • [8] USE OF NEAR-INFRARED SPECTROSCOPY ON FINGER DURING A VASCULAR OCCLUSION TEST TO ASSESS THE DYNAMIC TISSUE O2 SATURATION RESPONSE
    Lima, A.
    Alamyar, M.
    Bakker, J.
    [J]. INTENSIVE CARE MEDICINE, 2009, 35 : 205 - 205
  • [9] NEAR-INFRARED SPECTROSCOPY AND CHANGES IN TISSUE OXYGEN-SATURATION DURING EXERCISE
    BELARDINELLI, R
    BARSTOW, TJ
    WASSERMAN, K
    [J]. CIRCULATION, 1992, 86 (04) : 98 - 98
  • [10] Vascular responsiveness determined by near-infrared spectroscopy measures of oxygen saturation
    Mclay, Kaitlin M.
    Fontana, Federico Y.
    Nederveen, Josh P.
    Guida, Federico F.
    Paterson, Donald H.
    Pogliaghi, Silvia
    Murias, Juan M.
    [J]. EXPERIMENTAL PHYSIOLOGY, 2016, 101 (01) : 34 - 40