Screen-printed electrode modified with Co-NPs, as an electrochemical sensor for simultaneous determination of doxorubicin and dasatinib

被引:0
|
作者
Tahereh Kondori
Somayeh Tajik
Niloufar Akbarzadeh-T
Hadi Beitollahi
Claudia Graiff
机构
[1] University of Sistan and Baluchestan,Department of Chemistry
[2] Kerman University of Medical Sciences,Research Center of Tropical and Infectious Diseases
[3] Graduate University of Advanced Technology,Environment Department, Institute of Science and High Technology and Environmental Sciences
[4] University of Parma,Department of Chemistry, Life Sciences and Environmental Sustainability
关键词
Nanoparticle; Metal complex; Dasatinib; Screen-printed electrode;
D O I
暂无
中图分类号
学科分类号
摘要
The new metal complex of Co(II) (a1) and its nano-size, (a2), with NCS− and 5,5´-dimethyl-2,2´-bipyridine ligands have been synthesized. [Co(5,5´-dmbpy)3][Co(NCS)4] (a1) characterized through spectroscopic methods such as FTIR, UV–Vis, diffractometric analysis and elemental analysis. Nanoparticle (a2) has been identified with FTIR spectroscopy, also SEM, and XRD techniques. The size of the (a2) is about 86 nm. In this study, an electrochemical sensing platform for simultaneous detection of doxorubicin and dasatinib based on screen-printed electrode (SPE) modified with (a2) was prepared. The modified SPE, on the contrary to bare SPE, can considerably enhance activities of electrocatalytic towards oxidation of doxorubicin and dasatinib, followed by rising the anodic peak current. Peak currents obtained via differential pulse voltammetry (DPV) showed a linear enhancement as dasatinib concentration elevated and sensor detected in ranges more than that of the concentration limited area of 0.04–195.0 μM, detection limit equal to 12.0 nM (S/N = 3). DPV responses show that at the surface of modified SPE, obvious separation of the peak of doxorubicin and dasatinib oxidation has been reported from another with 400 mV potential difference between them. A lower limit of detection (LOD), higher sensitivity as well as stability resulted in an electrode that could be applied for analyzing different real compounds. Moreover, its functionality is favorable and desirable in analyzing biological fluids and drug compounds.
引用
收藏
页码:4423 / 4434
页数:11
相关论文
共 50 条
  • [1] Screen-printed electrode modified with Co-NPs, as an electrochemical sensor for simultaneous determination of doxorubicin and dasatinib
    Kondori, Tahereh
    Tajik, Somayeh
    Akbarzadeh-T, Niloufar
    Beitollahi, Hadi
    Graiff, Claudia
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2022, 19 (11) : 4423 - 4434
  • [2] Simultaneous Determination of Doxorubicin and Dasatinib by using Screen-Printed Electrode/Ni-Fe Layered Double Hydroxide
    Mohammadi, Sayed Zia
    Mousazadeh, Farideh
    Tajik, Somayeh
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2023, 62 (11) : 4646 - 4654
  • [3] Electrochemical determination of tramadol using modified screen-printed electrode
    Mohammadi, Sayed Zia
    Jafari, Maedeh
    Jahani, Peyman Mohammadzadeh
    Ahmadi, Sayed Ali
    Mashayekh, Raana
    JOURNAL OF ELECTROCHEMICAL SCIENCE AND ENGINEERING, 2022, 12 (01): : 127 - 135
  • [4] Electrochemical Determination of Hydrazine Based on Modified Screen-Printed Carbon Electrode
    Mohammadi, Sayed Zia
    Tajik, Somayeh
    Hamidian, Hooshang
    Mousazadeh, Farideh
    Emambakhsh, Fatemeh
    Sajadi, Pari-Sima
    Allahabadi, Hossein
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2025, 172 (01)
  • [5] Electrochemical Determination of Doxorubicin in the Presence of Dacarbazine Using MWCNTs/ZnO Nanocomposite Modified Disposable Screen-Printed Electrode
    Tajik, Somayeh
    Beitollahi, Hadi
    Nejad, Fariba Garkani
    Dourandish, Zahra
    BIOSENSORS-BASEL, 2025, 15 (01):
  • [6] Modified screen-printed Electrode as Electrochemical Detector for Noscapine
    Aflatoonian, Mohammad Reza
    Jahani, Peyman Mohammadzadeh
    Aflatoonian, Behnaz
    Jafari, Maedeh
    Zhang, Kaiqiang
    Quyet Van Le
    Cha, Joo Hwan
    Shokouhimehr, Mohammadreza
    Peng, Wanxi
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (09): : 8612 - 8621
  • [7] Polymer-modified screen-printed electrode-based electrochemical sensors for doxorubicin detection
    Dimitrievska, Iva
    Paunovic, Perica
    Grozdanov, Anita
    JOURNAL OF ELECTROCHEMICAL SCIENCE AND ENGINEERING, 2025, 15 (01):
  • [8] A Novel Electrochemical Sensor for Epinephrine in the Presence of Acetylcholine Based on Modified Screen-Printed Electrode
    Farideh Sayed Zia Mohammadi
    Hadis Mosazadeh
    Zohreh Beitollah
    Russian Journal of Electrochemistry, 2022, 58 : 248 - 257
  • [9] A Novel Electrochemical Sensor for Epinephrine in the Presence of Acetylcholine Based on Modified Screen-Printed Electrode
    Mohammadi, Sayed Zia
    Mosazadeh, Farideh
    Beitollah, Hadis
    Barani, Zohreh
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2022, 58 (04) : 248 - 257
  • [10] Development of an Electrochemical Sensor Based on Reduced Graphene Oxide Modified Screen-Printed Carbon Electrode for the Determination of Buprenorphine
    Fakhari, Ali Reza
    Sahragard, Ali
    Ahmar, Hamid
    ELECTROANALYSIS, 2014, 26 (11) : 2474 - 2483