Tibial component coverage and rotational alignment accuracy after mobile-bearing total knee arthroplasty

被引:5
|
作者
Ishii Y. [1 ]
Noguchi H. [1 ]
Sato J. [1 ]
Ishii H. [2 ]
Todoroki K. [1 ]
Toyabe S.-I. [3 ]
机构
[1] Ishii Orthopaedic and Rehabilitation Clinic, 1089 Shimo-Oshi, Gyoda, 361-0037, Saitama
[2] Kouseiren Takaoka Hospital, 5-10 Eirakutyo Takaoka, Toyama
[3] Niigata University Crisis Management Office, Niigata University Hospital, Niigata University Graduate School of Medical and Dental Sciences, 1 Asahimachi Dori Niigata, Niigata
关键词
LCS[!sup]®[!/sup; Mobile-bearing TKA; Tibial component coverage; Tibial rotational alignment;
D O I
10.1007/s00590-018-2155-5
中图分类号
学科分类号
摘要
Background: Tibial component coverage (TCC) and tibial rotational angle (TRA) have been studied simultaneously in simulations, but not in clinical studies after total knee arthroplasty (TKA). The purposes of this study were (1) to evaluate TCC and rotational setting postoperatively in mobile-bearing TKA patients and (2) to compare the results with previously published simulation data. Methods: We prospectively examined 100 patients who underwent primary TKA using the LCS® Total Knee System (LCS) posterior cruciate ligament-substituting prosthesis. Clinical outcomes, TCC (coverage area of the tibial component over the tibia), and TRA (relative to the femoral transepicondylar axis (TEA)) were assessed. Quantitative three-dimensional computed tomography was used to assess TCC and TRA. All values are expressed as median (25th percentile, 75th percentile) using minus (−) for internal and plus (+) for external rotation. Results: Hospital for Special Surgery scores improved from 46 (36, 50) preoperatively to 92 (90, 92) postoperatively. TRA showed a median divergence of − 2.0° (− 4.75°, + 2.74°). All knees were located within 10° of the TEA (range − 10.0° to + 9.7°). The median TCC of the knees was 82.7% (80.6, 84.7%), and there were no knees that hung over the tibial component in any direction. Conclusions: The LCS prosthesis had good clinical outcomes, comparable TCC, and improved TRA as compared to previous reports, as all knees were located within 10° of the TEA. Simultaneous optimization of both TCC and TRA may contribute to the excellent long-term outcomes that have been observed with this system. Level of evidence: Level II, Prognostic study. © 2018, Springer-Verlag France SAS, part of Springer Nature.
引用
收藏
页码:1143 / 1149
页数:6
相关论文
共 50 条
  • [1] The effect of tibial component rotational alignment on clinical outcomes of mobile-bearing unicompartmental knee arthroplasty
    Zhou, Xiaoqiang
    Sun, Chao
    Xu, Renjie
    Zhang, Xiangxin
    Yu, Xiao
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [2] The effect of tibial component rotational alignment on clinical outcomes of mobile-bearing unicompartmental knee arthroplasty
    Xiaoqiang Zhou
    Chao Sun
    Renjie Xu
    Xiangxin Zhang
    Xiao Yu
    [J]. Journal of Orthopaedic Surgery and Research, 18
  • [3] Rotational position of the tibial component can decrease bony coverage of the tibial component in Oxford mobile-bearing unicompartmental knee arthroplasty
    Kamenaga, Tomoyuki
    Hiranaka, Takafumi
    Hida, Yuichi
    Fujishiro, Takaaki
    Okamoto, Koji
    [J]. KNEE, 2019, 26 (02): : 459 - 465
  • [4] Rotational alignment of the tibial component in total knee arthroplasty
    Bindelglass, DF
    [J]. ORTHOPEDICS, 2001, 24 (11) : 1049 - 1052
  • [5] Rotational alignment of the tibial component in total knee arthroplasty
    Indelli, Pier Francesco
    Graceffa, Angelo
    Marcucci, Massimiliano
    Baldini, Andrea
    [J]. ANNALS OF TRANSLATIONAL MEDICINE, 2016, 4 (01)
  • [6] Axial Rotational Alignment in Mobile-Bearing Total Ankle Arthroplasty
    Hintermann, Beat
    Susdorf, Roman
    Krahenbuhl, Nicola
    Ruiz, Roxa
    [J]. FOOT & ANKLE INTERNATIONAL, 2020, 41 (05) : 521 - 528
  • [7] Accuracy of anatomical references used for rotational alignment of tibial component in total knee arthroplasty
    Namık Şahin
    Teoman Atıcı
    Alpaslan Öztürk
    Güven Özkaya
    Yüksel Özkan
    Bülent Avcu
    [J]. Knee Surgery, Sports Traumatology, Arthroscopy, 2012, 20 : 565 - 570
  • [8] Accuracy of anatomical references used for rotational alignment of tibial component in total knee arthroplasty
    Sahin, Namik
    Atici, Teoman
    Ozturk, Alpaslan
    Ozkaya, Guven
    Ozkan, Yuksel
    Avcu, Bulent
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2012, 20 (03) : 565 - 570
  • [9] Rotational alignment of the tibial component affects the kinematic rotation of a weight-bearing knee after total knee arthroplasty
    Nakahara, Hiroyuki
    Okazaki, Ken
    Hamai, Satoshi
    Kawahara, Shinya
    Higaki, Hidehiko
    Mizu-uchi, Hideki
    Iwamoto, Yukihide
    [J]. KNEE, 2015, 22 (03): : 201 - 205
  • [10] Femoral component rotation in mobile-bearing total knee arthroplasty
    Boldt, J. G.
    Stiehl, J. B.
    Munzinger, U.
    Beverland, D.
    Keblish, P. A.
    [J]. KNEE, 2006, 13 (04): : 284 - 289