Quantification of the bone-related mRNAs at the bone/prosthetic interface

被引:0
|
作者
J. A. Hunt
D. F. Williams
C. R. Howlett
H. Zreiqat
B. Zicat
机构
[1] University of Liverpool,Department of Clinical Engineering
[2] School of Pathology,Bone Biomaterial Unit
[3] UNSW,undefined
[4] Mater,undefined
[5] Misercordiae Hospital Sydney,undefined
关键词
Signalling Mode; Aseptic Loosening; Phenotypic Expression; cDNA Probe; Color Reaction;
D O I
暂无
中图分类号
学科分类号
摘要
Aseptic loosening is one of the major reasons for failure of joint prostheses. The periprosthetic tissue has previously been described microscopically; however, little work has been devoted towards quantitating genes expressed by cells at the materials/tissue interface. This study aims to characterize the phenotypic expression of osteoblasts and test the feasibility of quantifying the level of gene expression in periprosthetic tissue sections by combining in situ hybridization and image analysis techniques. There are many factors to consider when quantifying mRNA, in that comparing labeling between different cDNA probes, these should have comparable length and base comparison. The probes should be labeled with the same specific activity, that is the amount of probe to label added is the same, both between different probes and between batches of the same probe. Chromagen color reactions are variable in that the color development is not always linear and more likely follows a sigmoidal curve. Samples should only be compared when it is known that the reaction has been in the linear range. The image analysis of such staining introduces further factors which should be considered and controlled. Color analysis is a very complex problem with respect to reproducibly analyzing histological sections. The brightness component of the image should be independent of the colors within the image, in conventional RGB (red, green and blue) signalling mode this is not possible, while when using HSI (hue saturation and intensity) mode this becomes possible, and factors like staining intensity and brightness of the image become much more accountable and controllable. With these factors identified, we consider that the quantitative image analysis approach does allow comparison of patterns of bone-related mRNAs and demonstrates differences in expression in these osteogenic factors depending on distance from the prosthesis, tissue type, patient and device. © 1998 Kluwer Academic Publishers
引用
收藏
页码:691 / 694
页数:3
相关论文
共 50 条
  • [1] Quantification of the bone-related mRNAs at the bone/prosthetic interface
    Hunt, JA
    Williams, DF
    Howlett, CR
    Zreiqat, H
    Zicat, B
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1998, 9 (12) : 691 - 694
  • [2] Sonography of bone and bone-related diseases of the extremities
    Cho, KH
    Lee, YH
    Lee, SM
    Shahid, MU
    Suh, KJ
    Choi, JH
    [J]. JOURNAL OF CLINICAL ULTRASOUND, 2004, 32 (09) : 511 - 521
  • [3] Macrophages at the skeletal tissue-device interface of loosened prosthetic devices express bone-related genes and their products
    Zreiqat, H
    Kumar, RK
    Markovic, B
    Zicat, B
    Howlett, CR
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2003, 65A (01) : 109 - 117
  • [4] The effect of polymeric chemistry on the expression of bone-related mRNAs and proteins by human bone-derived cells in vitro
    Zreiqat, H
    McFarland, C
    Howlett, CR
    [J]. JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 1999, 10 (02) : 199 - 216
  • [5] Macrophages at the skeletal tissue/device interface of loosened prosthetic devices express a range of bone-related genes and their products.
    Zreiqat, H
    Markovic, B
    Zicat, B
    Howlett, CR
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 2001, 16 : S448 - S448
  • [6] Markers of bone remodeling in neoplastic and bone-related lesions
    Arantes Elias, Larissa Santana
    Costa, Rafael Ferreira
    Carvalho, Marco Aurelio
    Batista, Aline Carvalho
    Silva, Tarcilia Aparecida
    Leles, Claudio Rodrigues
    Mendonca, Elismauro Francisco
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2010, 110 (05): : 624 - 631
  • [7] Prosthetic particles modify the expression of bone-related proteins by human osteoblastic cells in vitro
    Zreiqat, H
    Crotti, TN
    Howlett, CR
    Capone, M
    Markovic, B
    Haynes, DR
    [J]. BIOMATERIALS, 2003, 24 (02) : 337 - 346
  • [8] BONE-RELATED GENES EXPRESSED IN THE BRAIN
    Takarada, T.
    Yoneda, Y.
    [J]. JOURNAL OF NEUROCHEMISTRY, 2009, 110 : 111 - 111
  • [9] A fish bone-related hepatic abscess
    Jarry, Julien
    Nguyen, Vien
    Stoltz, Adeline
    Imperato, Marc
    Michel, Philippe
    [J]. CLINICS AND PRACTICE, 2011, 1 (04) : 249 - 250
  • [10] Association of bone-related biomarkers with femoral neck bone strength
    Xia, Ning
    Cai, Yun
    Wang, Wei
    Bao, Chen
    Li, Yunming
    Xie, Qingyun
    Xu, Wei
    Liu, Da
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)