Small-field dosimetry with detector-specific output correction factor for single-isocenter stereotactic radiotherapy of single and multiple brain metastases

被引:0
|
作者
Tomohiro Ono
Kohei Kawata
Mitsuhiro Nakamura
Megumi Uto
Takashi Mizowaki
机构
[1] Kyoto University,Department of Radiation Oncology and Image
[2] Kyoto University Hospital,Applied Therapy, Graduate School of Medicine
[3] Kyoto University,Division of Clinical Radiology Service
来源
关键词
Small-field dosimetry; Multiple brain metastases; Detector-dependent output correction factor; Patient-specific quality assurance;
D O I
暂无
中图分类号
学科分类号
摘要
Recently, the International Atomic Energy Agency and the American Association of Physicists in Medicine reported correction factors (CFs) for detector-response variation considering the uncertainty in detector readings in small-field dosimetry. In this study, the effect of CFs on small-field dosimetry measurements was evaluated for single-isocenter stereotactic radiotherapy for brain metastases. The output factors (OPFs) were measured with and without CFs in a water-equivalent sphere phantom using TrueBeam with a flattening-filter-free energy of 10 MV. Five detectors were used in a perpendicular orientation: CC01, 3D pinpoint ionization chambers, unshielded SFD detector, shielded EDGE detector, and microDiamond detector. First, the square-field sizes were set to 5–100 mm using a multi-leaf collimator (MLC) field. The OPFs were evaluated in the presence and absence of CFs. Second, single-isocenter stereotactic irradiation was performed on 22 brain metastases in 15 patients following dynamic conformal arc (DCA) treatment. The equivalent field size was calculated using the MLC aperture for each planning target volume. For the OPFs, the mean deviations from the median of the doses measured with detectors other than the CC01 for square-field sizes larger than 10 mm were within ± 4.3% of the median without CFs, and ± 3.3% with CFs. For DCA plans, the deviations without and with CFs were − 2.3 ± 1.9% and − 4.8 ± 2.4% for CC01, − 1.1 ± 3.0% and 1.0 ± 1.6% for 3D pinpoint, 8.8 ± 3.0% and 2.9 ± 2.8% for SFD, − 3.1 ± 3.0% and − 13.5 ± 4.0% for EDGE, and 8.9 ± 2.1% and 0.8 ± 1.9% for microDiamond. This feasibility study confirmed that the deviation of the detectors can be reduced using an appropriate detector with CFs.
引用
收藏
页码:10 / 19
页数:9
相关论文
共 50 条
  • [1] Small-field dosimetry with detector-specific output correction factor for single-isocenter stereotactic radiotherapy of single and multiple brain metastases
    Ono, Tomohiro
    Kawata, Kohei
    Nakamura, Mitsuhiro
    Uto, Megumi
    Mizowaki, Takashi
    [J]. RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2023, 16 (01) : 10 - 19
  • [2] Small-Field Dosimetry in Single-Isocenter Stereotactic Irradiation for Brain Metastases Using a Detector-Specific Field Output Correction Factor
    Ono, T.
    Nakamura, M.
    Uto, M.
    Mizowaki, T.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [3] Stereotactic radiotherapy with single-isocenter in multiple brain metastases
    Matteucci, P.
    Silipigni, S.
    Rinaldi, C. G.
    Ridolfi, I.
    Falco, P.
    Fiore, M.
    Ippolito, E.
    Ramella, S.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S866 - S867
  • [4] Film dosimetry of single isocenter stereotactic radiotherapy for multiple brain metastases
    Bogers, L.
    Zindler, J.
    de Goede, M.
    Mudde-van der Wouden, I.
    Petoukhova, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1439 - S1440
  • [5] Effect of the Rotational Error On the Dose Distribution with Single-Isocenter Technique of Stereotactic Radiotherapy for Multiple Brain Metastases
    Nakano, H.
    Tanabe, S.
    Utsunomiya, S.
    Takizawa, T.
    Yamada, T.
    Sakai, H.
    Aoyama, H.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E652 - E652
  • [6] Knowledge-Based Stereotactic Planning for Single-Isocenter Multiple Brain Metastases
    Robar, J. L.
    MacDonald, R. L.
    Phillips, H.
    Spiessens, S.
    Thomas, C.
    Yewondwossen, M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E641 - E642
  • [7] Effective method to reduce the normal brain dose in single-isocenter hypofractionated stereotactic radiotherapy for multiple brain metastases
    Lai, Jialu
    Liu, Jia
    Zhao, Jianling
    Li, An
    Liu, Shoupeng
    Deng, Zhonghua
    Tan, Qiaoyue
    Wang, Haitao
    Jia, Yuming
    Lei, Kaijian
    Zhou, Lin
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2021, 197 (07) : 592 - 600
  • [8] Effective method to reduce the normal brain dose in single-isocenter hypofractionated stereotactic radiotherapy for multiple brain metastases
    Jialu Lai
    Jia Liu
    Jianling Zhao
    An Li
    Shoupeng Liu
    Zhonghua Deng
    Qiaoyue Tan
    Haitao Wang
    Yuming Jia
    Kaijian Lei
    Lin Zhou
    [J]. Strahlentherapie und Onkologie, 2021, 197 : 592 - 600
  • [9] Stereotactic radiosurgery with single-isocenter dynamic arc therapy of multiple brain metastases
    Bodensohn, R.
    Kaempfel, A.
    Fleischmann, D. F.
    Hofmaier, J.
    Hadi, I.
    Garny, S.
    Reiner, M.
    Corradini, S.
    Forbrig, R.
    Thon, N.
    Belka, C.
    Niyazi, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S470 - S471
  • [10] Clinical Outcomes of Single-Isocenter Versus Multiple-Isocenter Stereotactic Radiosurgery Techniques for Multiple Brain Metastases
    Deng, J.
    Li, M. K.
    Savjani, R. R.
    Chu, F. I.
    Tenn, S. E.
    Lee, C.
    Agazaryan, N.
    Yang, I.
    Everson, R.
    Kim, W.
    Pouratian, N.
    Kishan, A. U.
    Chin, R. K.
    Steinberg, M. L.
    Kaprealian, T. B.
    Hegde, J. V.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2021, 111 (03): : E566 - E567