Real-time diameter of the fetal aorta from ultrasound

被引:0
|
作者
Nicoló Savioli
Enrico Grisan
Silvia Visentin
Erich Cosmi
Giovanni Montana
Pablo Lamata
机构
[1] King’s College London,Department of Biomedical Engineering
[2] Department of Computing,Department of Woman and Child Health
[3] Imperial College London,WMG International Digital Laboratory
[4] University Hospital of Padova,Department of Information Engineering
[5] University of Warwick,undefined
[6] University of Padova,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The automatic analysis of ultrasound sequences can substantially improve the efficiency of clinical diagnosis. This article presents an attempt to automate the challenging task of measuring the vascular diameter of the fetal abdominal aorta from ultrasound images. We propose a neural network architecture consisting of three blocks: a convolutional neural network (CNN) for the extraction of imaging features, a convolution gated recurrent unit (C-GRU) for exploiting the temporal redundancy of the signal, and a regularized loss function, called CyclicLoss, to impose our prior knowledge about the periodicity of the observed signal. The solution is investigated with a cohort of 25 ultrasound sequences acquired during the third-trimester pregnancy check, and with 1000 synthetic sequences. In the extraction of features, it is shown that a shallow CNN outperforms two other deep CNNs with both the real and synthetic cohorts, suggesting that echocardiographic features are optimally captured by a reduced number of CNN layers. The proposed architecture, working with the shallow CNN, reaches an accuracy substantially superior to previously reported methods, providing an average reduction of the mean squared error from 0.31 (state-of-the-art) to 0.09 mm2\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\mathrm{mm}^2$$\end{document}, and a relative error reduction from 8.1 to 5.3%. The mean execution speed of the proposed approach of 289 frames per second makes it suitable for real-time clinical use.
引用
收藏
页码:6735 / 6744
页数:9
相关论文
共 50 条
  • [1] Real-time diameter of the fetal aorta from ultrasound
    Savioli, Nicolo
    Grisan, Enrico
    Visentin, Silvia
    Cosmi, Erich
    Montana, Giovanni
    Lamata, Pablo
    [J]. NEURAL COMPUTING & APPLICATIONS, 2020, 32 (11): : 6735 - 6744
  • [2] Temporal Convolution Networks for Real-Time Abdominal Fetal Aorta Analysis with Ultrasound
    Savioli, Nicolo
    Visentin, Silvia
    Cosmi, Erich
    Grisan, Enrico
    Lamata, Pablo
    Montana, Giovanni
    [J]. ARTIFICIAL NEURAL NETWORKS AND MACHINE LEARNING - ICANN 2018, PT II, 2018, 11140 : 148 - 157
  • [3] FETAL WEIGHT ESTIMATION BY REAL-TIME ULTRASOUND MEASUREMENT OF BIPARIETAL AND TRANSVERSE TRUNK DIAMETER
    DORNAN, KJ
    HANSMANN, M
    REDFORD, DHA
    WITTMANN, BK
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1982, 142 (06) : 652 - 657
  • [4] REAL-TIME ULTRASOUND OBSERVATION OF FETAL ACTIVITY IN LABOR
    WITTMANN, BK
    DAVISON, BM
    LYONS, E
    FROHLICH, J
    TOWELL, ME
    [J]. BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1979, 86 (04): : 278 - 281
  • [5] GROWTH OF THE FETAL KIDNEY ASSESSED BY REAL-TIME ULTRASOUND
    SATO, A
    YAMAGUCHI, Y
    LIOU, SM
    SATO, M
    SUZUKI, M
    [J]. GYNECOLOGIC AND OBSTETRIC INVESTIGATION, 1985, 20 (01) : 1 - 5
  • [6] DIAGNOSIS OF FETAL DEATH INUTERO BY REAL-TIME ULTRASOUND
    PLATT, LD
    MANNING, FA
    MURATA, Y
    KEEGAN, KA
    DRUZIN, ML
    SOCOL, ML
    [J]. OBSTETRICS AND GYNECOLOGY, 1980, 55 (02): : 191 - 193
  • [7] EARLY FETAL MOVEMENT - REAL-TIME ULTRASOUND STUDY
    SHAWKER, TH
    SCHUETTE, WH
    WHITEHOUSE, W
    RIFKA, SM
    [J]. OBSTETRICS AND GYNECOLOGY, 1980, 55 (02): : 194 - 198
  • [8] DETECTION OF FETAL ANENCEPHALY USING REAL-TIME ULTRASOUND
    HARWOOD, SJ
    PINSKER, MC
    [J]. SOUTHERN MEDICAL JOURNAL, 1979, 72 (02) : 223 - 225
  • [9] Real-Time Ultrasound Assessment of Body and Breathing Movements and Abdominal Diameter in Fetal Lambs From 55 Days of Gestation to Term
    Rurak, Dan
    Wittman, Bernd
    [J]. REPRODUCTIVE SCIENCES, 2013, 20 (04) : 414 - 425
  • [10] Real-Time Ultrasound Assessment of Body and Breathing Movements and Abdominal Diameter in Fetal Lambs From 55 Days of Gestation to Term
    Dan Rurak
    Bernd Wittman
    [J]. Reproductive Sciences, 2013, 20 : 414 - 425