Design study of the KAGRA output mode cleaner

被引:0
|
作者
Ayaka Kumeta
Charlotte Bond
Kentaro Somiya
机构
[1] Tokyo Institute of Technology,Department of Physics
[2] University of Birmingham,School of Physics and Astronomy
来源
Optical Review | 2015年 / 22卷
关键词
Interferometer; Simulation; Gravitational waves;
D O I
暂无
中图分类号
学科分类号
摘要
Most second-generation gravitational-wave detectors employ an optical resonator called an output mode cleaner (OMC), which filters out junk light from the signal and the reference light, before it reaches the detection photodiode located at the asymmetric port of the large-scale interferometer. The optical parameters of the OMC should be carefully chosen to satisfy the requirements to filter out unwanted light whilst transmitting the gravitational-wave signal. We use the simulation program FINESSE and realistic mirror phase maps that have the same surface quality as the KAGRA test masses to find out a proper design of the KAGRA OMC.
引用
收藏
页码:149 / 152
页数:3
相关论文
共 50 条
  • [1] Design study of the KAGRA output mode cleaner
    Kumeta, Ayaka
    Bond, Charlotte
    Somiya, Kentaro
    [J]. OPTICAL REVIEW, 2015, 22 (01) : 149 - 152
  • [2] Design study and prototype experiment of the KAGRA output mode-cleaner
    Yano, Kazushiro
    Kumeta, Ayaka
    Somiya, Kentaro
    [J]. 11TH EDOARDO AMALDI CONFERENCE ON GRAVITATIONAL WAVES (AMALDI 11), 2016, 716
  • [3] Optical design and suspension system of the KAGRA output mode-cleaner
    Kasuya, Junko
    Winterflood, John
    Li, Ju
    Somiya, Kentaro
    [J]. 12TH EDOARDO AMALDI CONFERENCE ON GRAVITATIONAL WAVES (AMALDI 12), 2018, 957
  • [4] The output mode cleaner of GEO 600
    Prijatelj, M.
    Degallaix, J.
    Grote, H.
    Leong, J.
    Affeldt, C.
    Hild, S.
    Lueck, H.
    Slutsky, J.
    Wittel, H.
    Strain, K.
    Danzmann, K.
    [J]. CLASSICAL AND QUANTUM GRAVITY, 2012, 29 (05)
  • [5] Design and prototype tests of a seismic attenuation system for the advanced-LIGO output mode cleaner
    Bertolini, A.
    DeSalvo, R.
    Galli, C.
    Gennaro, G.
    Mantovani, M.
    Marka, S.
    Sannibale, V.
    Takamori, A.
    Torrie, C.
    [J]. CLASSICAL AND QUANTUM GRAVITY, 2006, 23 (08) : S111 - S118
  • [6] Control and automatic alignment of the output mode cleaner of GEO 600
    Prijatelj, M.
    Grote, H.
    Degallaix, J.
    Hewitson, M.
    Hild, S.
    Affeldt, C.
    Freise, A.
    Leong, J.
    Lueck, H.
    Strain, K. A.
    Wittel, H.
    Willke, B.
    Danzmann, K.
    [J]. 8TH EDOARDO AMALDI CONFERENCE ON GRAVITATIONAL WAVES, 2010, 228
  • [7] Noise Conversion of a Mode-cleaner Cavity and Noise Analysis of Output Fields
    Wang Xiaohui
    Yan Hongmei
    Yang Wenguang
    Jing Mingyong
    Zhang Hao
    Zhang Linjie
    [J]. ACTA PHOTONICA SINICA, 2022, 51 (04) : 33 - 39
  • [8] Optical design of a high power mode-cleaner for AIGO
    Barriga, P
    Zhao, C
    Blair, DG
    [J]. GENERAL RELATIVITY AND GRAVITATION, 2005, 37 (09) : 1609 - 1619
  • [9] Optical design of a high power mode-cleaner for AIGO
    P. Barriga
    C. Zhao
    D. G. Blair
    [J]. General Relativity and Gravitation, 2005, 37 : 1609 - 1619
  • [10] Upper-limit on the Advanced Virgo output mode cleaner cavity length noise
    Bonnand, R.
    Ducrot, M.
    Gouaty, R.
    Marion, F.
    Masserot, A.
    Mours, B.
    Pacaud, E.
    Rolland, L.
    Was, M.
    [J]. CLASSICAL AND QUANTUM GRAVITY, 2017, 34 (17)