Sensitivity of MEG and EEG to Source Orientation

被引:0
|
作者
Seppo P. Ahlfors
Jooman Han
John W. Belliveau
Matti S. Hämäläinen
机构
[1] MGH/HST Athinoula A. Martinos Center for Biomedical Imaging,
[2] Massachusetts General Hospital/Harvard Medical School,undefined
[3] Harvard-MIT Division of Health Sciences and Technology,undefined
来源
Brain Topography | 2010年 / 23卷
关键词
Magnetoencephalography; Electroencephalography; Suppression ratio; Current dipole; Radial source current;
D O I
暂无
中图分类号
学科分类号
摘要
An important difference between magnetoencephalography (MEG) and electroencephalography (EEG) is that MEG is insensitive to radially oriented sources. We quantified computationally the dependency of MEG and EEG on the source orientation using a forward model with realistic tissue boundaries. Similar to the simpler case of a spherical head model, in which MEG cannot see radial sources at all, for most cortical locations there was a source orientation to which MEG was insensitive. The median value for the ratio of the signal magnitude for the source orientation of the lowest and the highest sensitivity was 0.06 for MEG and 0.63 for EEG. The difference in the sensitivity to the source orientation is expected to contribute to systematic differences in the signal-to-noise ratio between MEG and EEG.
引用
收藏
页码:227 / 232
页数:5
相关论文
共 50 条
  • [1] Sensitivity of MEG and EEG to Source Orientation
    Ahlfors, Seppo P.
    Han, Jooman
    Belliveau, John W.
    Haemaelaeinen, Matti S.
    [J]. BRAIN TOPOGRAPHY, 2010, 23 (03) : 227 - 232
  • [2] EEG and MEG: sensitivity to epileptic spike activity as function of source orientation and depth
    Hunold, A.
    Funke, M. E.
    Eichardt, R.
    Stenroos, M.
    Haueisen, J.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2016, 37 (07) : 1146 - 1162
  • [3] EEG and MEG source localization
    Rampp S.
    [J]. Zeitschrift für Epileptologie, 2018, 31 (2): : 109 - 112
  • [4] Sensitivity of EEG and MEG to conductivity perturbations
    Acar, CE
    Gençer, NG
    [J]. PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 2834 - 2837
  • [5] Sensitivity distributions of EEG and MEG measurements
    Malmivuo, J
    Suihko, V
    Eskola, H
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (03) : 196 - 208
  • [6] Source Connectivity Analysis With MEG and EEG
    Schoffelen, Jan-Mathijs
    Gross, Joachim
    [J]. HUMAN BRAIN MAPPING, 2009, 30 (06) : 1857 - 1865
  • [7] MEG and EEG source localization in beamspace
    Rodríguez-Rivera, A
    Baryshnikov, BV
    Van Veen, BD
    Wakai, RT
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2006, 53 (03) : 430 - 441
  • [8] Simultaneous EEG and MEG source analysis
    van Zuijen, TL
    Heslenfeld, DJ
    Huizenga, HM
    [J]. JOURNAL OF PSYCHOPHYSIOLOGY, 2000, 14 (04) : 266 - 266
  • [9] Simultaneous MEG and EEG source analysis
    Huizenga, HM
    van Zuijen, TL
    Heslenfeld, DJ
    Molenaar, PCM
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (07): : 1737 - 1751
  • [10] Voxel-ICA for reconstruction of source signal time-series and orientation in EEG and MEG
    Yaqub Jonmohamadi
    Govinda Poudel
    Carrie Innes
    Richard Jones
    [J]. Australasian Physical & Engineering Sciences in Medicine, 2014, 37 : 457 - 464