Effects of continuous positive airway pressure on diaphragm dimensions in preterm infants

被引:20
|
作者
Rehan V.K. [1 ]
Laiprasert J. [1 ]
Nakashima J.M. [2 ]
Wallach M. [4 ]
McCool F.D. [3 ]
机构
[1] Departments of Pediatrics, Memorial Hospital of Rhode Island, Pawtucket, RI
[2] Departments of Pathology, Memorial Hospital of Rhode Island, Pawtucket, RI
[3] Departments of Medicine, Memorial Hospital of Rhode Island, Pawtucket, RI
[4] Departments of Pediatrics and Radiology, Women and Infants’ Hospital, Brown University School of Medicine, Providence, RI
关键词
D O I
10.1038/sj.jp.7210587
中图分类号
学科分类号
摘要
Objective: The use of continuous positive airway pressure (CPAP) in the treatment of a variety of neonatal respiratory conditions is associated with improvement in arterial oxygen saturation, decreased long-term morbidity, and an overall improvement in infant survival. We reasoned that CPAP might change diaphragm length by increasing end-expiratory lung volume (EEV), but the extent to which this occurs has not been assessed. This study was designed to evaluate (1) the extent to which CPAP shortens the diaphragm and (2) the relationship of diaphragm thickness and excursion with arterial oxygen saturation in spontaneously breathing preterm infants. Study design: Ultrasonographically (7.5 MHz transducer), diaphragm thickness and diaphragm excursion were measured in 12 stable preterm infants [birth weight 1120±225 g (mean±SD); study weight 1187±400 g; gestational age 29±1 week; postnatal age 10±8 days, six males and six females] at three levels of CPAP [1-3, 4-6, and 7-9 cm H2O (low, medium, and high, respectively)]. Heart rate, respiratory rate, and arterial oxygen saturation were simultaneously recorded. Results: We found that diaphragm thickness and arterial oxygen saturation increased, and diaphragm excursion decreased significantly at higher levels of CPAP (p<0.05). The shortening of the diaphragm at the high levels of CPAP, calculated from the increase in diaphragm thickness, was 36% at EEV and 31% at end-inspiratory volume. Conclusion: We conclude that the improvement in arterial oxygen saturation with CPAP occurred despite the presence of a shorter and a less mobile diaphragm, and that other physiological and mechanical alterations accompanying the application of CPAP offset its negative effects on diaphragm function. We speculate that with excessive CPAP, however, diaphragm dysfunction along with the previously described adverse hemodynamic effects may outweigh its benefits on oxygenation.
引用
收藏
页码:521 / 524
页数:3
相关论文
共 50 条
  • [1] Effects of Nasal Continuous Positive Airway Pressure on Cerebral Hemodynamics in Preterm Infants
    Zhou, Han
    Hou, Xuewen
    Cheng, Rui
    Zhao, Youyan
    Qiu, Jie
    [J]. FRONTIERS IN PEDIATRICS, 2020, 8
  • [2] Decreasing Continuous Positive Airway Pressure Failure in Preterm Infants
    Kakkilaya, Venkatakrishna B.
    Weydig, Heather M.
    Smithhart, William E.
    Renfro, Shelly D.
    Garcia, Kristi M.
    Brown, Cari M.
    He, Henry
    Wagner, Sheron A.
    Metoyer, Glenn C.
    Brown, L. Steven
    Kapadia, Vishal S.
    Savani, Rashmin C.
    Jaleel, Mambarambath A.
    [J]. PEDIATRICS, 2021, 148 (04) : 85 - 95
  • [3] Nasal continuous positive airway pressure and outcomes of preterm infants
    De Klerk, AM
    De Klerk, RK
    [J]. JOURNAL OF PAEDIATRICS AND CHILD HEALTH, 2001, 37 (02) : 161 - 167
  • [4] Lung and diaphragm ultrasound as predictors of successful weaning from nasal continuous positive airway pressure in preterm infants
    Nour, Basma Ahmed
    Abd El-Rahman, Ashraf Mohamed
    Abd El Hameed, Suzy Abd Elmabood
    Mohsen, Nada
    Mohamed, Adel
    El-Bayoumi, Mohammed Attia
    Abdel-Hady, Hesham Elsayed
    [J]. PEDIATRIC PULMONOLOGY, 2024, 59 (05) : 1428 - 1437
  • [5] Pharyngeal pressure in preterm infants receiving nasal continuous positive airway pressure
    De Paoli, AG
    Lau, R
    Davis, PG
    Morley, CJ
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2005, 90 (01): : F79 - F81
  • [6] Comparative Study of the Effects of Continuous Positive Airway Pressure and Nasal High-Flow Therapy on Diaphragmatic Dimensions in Preterm Infants
    El-Mogy, Mohamed
    El-Halaby, Hanan
    Attia, Gehan
    Abdel-Hady, Hesham
    [J]. AMERICAN JOURNAL OF PERINATOLOGY, 2018, 35 (05) : 448 - 454
  • [8] Neonatal helmet-continuous positive airway pressure in preterm infants
    Trevisanuto, D.
    Doglioni, N.
    Grazzina, N.
    [J]. ANAESTHESIA, PAIN, INTENSIVE CARE AND EMERGENCY MEDICINE, 2005, : 787 - 793
  • [9] TRANSCUTANEOUS ELECTROMYOGRAPHY OF THE DIAPHRAGM TO COMPARE NASAL CONTINUOUS POSITIVE AIRWAY PRESSURE AND HIGH FLOW NASAL CANNULA IN PRETERM INFANTS
    De Waal, C. G.
    De Jongh, F. H. C.
    Van Kaam, A. H. L. C.
    Hutten, G. J.
    [J]. EUROPEAN JOURNAL OF PEDIATRICS, 2016, 175 (11) : 1594 - 1595
  • [10] The effects of oral feeding while on nasal continuous positive airway pressure (NCPAP) in preterm infants
    Dumpa, Vikramaditya
    Kamity, Ranjith
    Ferrara, Louisa
    Akerman, Meredith
    Hanna, Nazeeh
    [J]. JOURNAL OF PERINATOLOGY, 2020, 40 (06) : 909 - 915