Longest reported support (7.5 years) with postauricular type of Jarvik 2000 axial-flow left ventricular assist device

被引:0
|
作者
Sofia Martin-Suarez
Mariafrancesca Fiorentino
Antonio Loforte
Marco Masetti
Luciano Potena
Davide Pacini
机构
[1] S. Orsola Hospital,Cardiac Surgery Unit, Cardio Thoracic and Vascular Department
[2] University of Bologna,Cardiology Unit, Cardio Thoracic and Vascular Department
[3] S. Orsola Hospital,undefined
[4] University of Bologna,undefined
来源
关键词
Mechanical Support; Drive line; Heart transplantation;
D O I
暂无
中图分类号
学科分类号
摘要
Mechanical circulatory supports with left ventricular assist devices (LVAD) are nowadays an established treatment in end-stage heart failure for those patients who are waiting for an organ donation or are unsuitable for transplantation. The duration of LVAD support is variable, depending on the device, the intention to treat and the issues occurring during treatment, which can change the purpose treatment or accelerate the transplantation. Moreover, length of reported supports in the literature is heterogenous. In here, we present the clinical and surgical case of the longest LVAD support reported in the literature, as a bridge to transplantation, with axial pump Jarvik 2000 (Jarvik Heart, Inc, New York, NY).
引用
收藏
页码:503 / 506
页数:3
相关论文
共 50 条
  • [1] Longest reported support (7.5 years) with postauricular type of Jarvik 2000 axial-flow left ventricular assist device
    Martin-Suarez, Sofia
    Fiorentino, Mariafrancesca
    Loforte, Antonio
    Masetti, Marco
    Potena, Luciano
    Pacini, Davide
    [J]. JOURNAL OF ARTIFICIAL ORGANS, 2021, 24 (04) : 503 - 506
  • [2] Research and development of an implantable, axial-flow left ventricular assist device: The Jarvik 2000 heart
    Frazier, OH
    Myers, TJ
    Jarvik, RK
    Westaby, S
    Pigott, DW
    Gregoric, ID
    Khan, T
    Tamez, DW
    Conger, JL
    Macris, MP
    [J]. ANNALS OF THORACIC SURGERY, 2001, 71 (03): : S125 - S132
  • [3] Midterm experience with the Jarvik 2000 axial flow left ventricular assist device
    Haj-Yahia, Saleem
    Birks, Emma J.
    Rogers, Paula
    Bowles, Christopher
    Hipkins, Mandy
    George, Robert
    Amrani, Mohammed
    Petrou, Mario
    Pepper, John
    Dreyfus, Gilles
    Khaghani, Asghar
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2007, 134 (01): : 199 - 203
  • [4] Intermediate experience with the Jarvik 2000 axial flow left ventricular assist device (LVAD)
    Haj-Yahya, S. M.
    Birks, E. J.
    Hardy, J.
    Hipkin, M.
    Bowles, C.
    Dreyfus, G.
    Banner, N.
    Khaghani, A.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2005, 24 (02): : S58 - S58
  • [5] Initial clinical experience with the Jarvik 2000 implantable axial-flow left ventricular assist system
    Frazier, OH
    Myers, TJ
    Gregoric, ID
    Khan, T
    Delgado, R
    Croitoru, M
    Miller, K
    Jarvik, R
    Westaby, S
    [J]. CIRCULATION, 2002, 105 (24) : 2855 - 2860
  • [6] Gastrointestinal bleeding from arteriovenous malformations in patients supported by the Jarvik 2000 axial-flow left ventricular assist device
    Letsou, GV
    Shah, N
    Gregoric, ID
    Myers, TJ
    Delgado, R
    Frazier, OH
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2005, 24 (01): : 105 - 109
  • [7] Current Axial-Flow Devices-the HeartMate II and Jarvik 2000 Left Ventricular Assist Devices
    John, Ranjit
    [J]. SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2008, 20 (03) : 264 - 272
  • [8] Continuous axial-flow left ventricular assist device (Jarvik 2000) maintains kidney and liver perfusion for up to 6 months
    Letsou, GV
    Myers, TJ
    Gregoric, ID
    Delgado, R
    Shah, N
    Robertson, K
    Radovancevic, B
    Frazier, OH
    [J]. ANNALS OF THORACIC SURGERY, 2003, 76 (04): : 1167 - 1170
  • [9] Clinical results with Jarvik 2000 axial flow left ventricular assist device: Osaka University Experience
    Daisuke Yoshioka
    Goro Matsumiya
    Koichi Toda
    Taichi Sakaguchi
    Yasushi Yoshikawa
    Shunsuke Saito
    Hikaru Matsuda
    Yoshiki Sawa
    [J]. Journal of Artificial Organs, 2014, 17 : 308 - 314
  • [10] Durability testing of components for the Jarvik 2000 completely implantable axial flow left ventricular assist device
    Marlinski, E
    Jacobs, G
    Deirmengian, C
    Jarvik, R
    [J]. ASAIO JOURNAL, 1998, 44 (05) : M741 - M744