Directional vector visualization of scattered rays in mobile c-arm fluoroscopy

被引:0
|
作者
Kyoko Hizukuri
Toshioh Fujibuchi
Hiroyuki Arakawa
机构
[1] Kyushu University,Division of Medical Quantum Science, Department of Health Sciences, Graduate School of Medical Sciences
[2] Kyushu University,Division of Medical Quantum Science, Department of Health Sciences, Faculty of Medical Sciences
来源
关键词
Scattered ray; Vector; X-ray fluoroscopy; Protective plate; Visualization; Occupational exposure;
D O I
暂无
中图分类号
学科分类号
摘要
Previous radiation protection-measure studies for medical staff who perform X-ray fluoroscopy have employed simulations to investigate the use of protective plates and their shielding effectiveness. Incorporating directional information enables users to gain a clearer understanding of how to position protective plates effectively. Therefore, in this study, we propose the visualization of the directional vectors of scattered rays. X-ray fluoroscopy was performed; the particle and heavy-ion transport code system was used in Monte Carlo simulations to reproduce the behavior of scattered rays in an X-ray room by reproducing a C-arm X-ray fluoroscopy system. Using the calculated results of the scattered-ray behavior, the vectors of photons scattered from the phantom were visualized in three dimensions. A model of the physician was placed on the directional vectors and dose distribution maps to confirm the direction of the scattered rays toward the physician when the protective plate was in place. Simulation accuracy was confirmed by measuring the ambient dose equivalent and comparing the measured and calculated values (agreed within 10%). The directional vectors of the scattered rays radiated outward from the phantom, confirming a large amount of backscatter radiation. The use of a protective plate between the patient and the physician’s head part increased the shielding effect, thereby enhancing radiation protection for the physicians compared to cases without the protective plate. The use of directional vectors and the surrounding dose-equivalent distribution of this method can elucidate the appropriate use of radiation protection plates.
引用
收藏
页码:288 / 296
页数:8
相关论文
共 50 条
  • [1] Directional vector visualization of scattered rays in mobile c-arm fluoroscopy
    Hizukuri, Kyoko
    Fujibuchi, Toshioh
    Arakawa, Hiroyuki
    [J]. RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2024, 17 (01) : 288 - 296
  • [2] Hysterosalpingography with use of mobile C-arm fluoroscopy
    Phillips, Jordana
    Cochavi, Saadia
    Silberzweig, James E.
    [J]. FERTILITY AND STERILITY, 2010, 93 (06) : 2065 - 2068
  • [3] C-ARM FLUOROSCOPY
    COHEN, MD
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (03) : 646 - 647
  • [4] C-ARM FLUOROSCOPY - REPLY
    DAVIS, M
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (03) : 647 - 647
  • [5] Quality assurance programme applied to mobile C-arm fluoroscopy systems
    Tuohy, B
    Marsh, DM
    OReilly, G
    Dowling, A
    Cooney, P
    Malone, JF
    [J]. EUROPEAN RADIOLOGY, 1997, 7 (04) : 534 - 541
  • [6] Quality assurance programme applied to mobile C-arm fluoroscopy systems
    B. Tuohy
    D. M. Marsh
    G. O'Reilly
    A. Dowling
    P. Cooney
    J. F. Malone
    [J]. European Radiology, 1997, 7 : 534 - 541
  • [7] Scattered Radiation Risk To The Lens Of The Eyes For Staff Involved In Using Mobile C-Arm Fluoroscopy Unit: Which Position Is Riskiest?
    Salleh, H.
    Samat, S. B.
    Matori, M. K.
    Isa, M. J. M.
    [J]. 2015 UKM FST POSTGRADUATE COLLOQUIUM, 2015, 1678
  • [8] Brass filtration considerations in reducing patient dose in mobile C-arm fluoroscopy
    Nishino, TK
    Barnes, GT
    [J]. RADIOLOGY, 2001, 221 : 336 - 336
  • [9] C-arm fluoroscopy in orthopaedic surgical practice
    Ojodu I.
    Ogunsemoyin A.
    Hopp S.
    Pohlemann T.
    Ige O.
    Akinola O.
    [J]. European Journal of Orthopaedic Surgery & Traumatology, 2018, 28 (8) : 1563 - 1568
  • [10] Effect of metallic tools on scattered radiation dose during the use of C-arm fluoroscopy in orthopaedic surgery
    Sung, Ki Hyuk
    Jung, Young-Jun
    Cha, Hyemi
    Chung, Chin Youb
    Lee, Kisung
    Park, Moon Seok
    [J]. JOURNAL OF RADIATION RESEARCH, 2019, 60 (01) : 1 - 6