Does ultrasonographic assessment of gastric antrum correlate with gastric residual volume in critically ill patients? A prospective observational study

被引:0
|
作者
Gurhan Taskin
Volkan Inal
Levent Yamanel
机构
[1] University of Health Sciences,Department of Intensive Care
[2] Trabzon Kanuni Training and Research Hospital,Department of Intensive Care, Faculty of Medicine
[3] Trakya University,Department of Intensive Care
[4] University of Health Sciences,undefined
[5] Gulhane Training and Research Hospital,undefined
关键词
Critical care; Ultrasonography; Enteral nutrition; Feeding intolerance; Gastric volume;
D O I
暂无
中图分类号
学科分类号
摘要
This study aimed to evaluate the relationship between ultrasonographic gastric antral measurements and aspirated gastric residual volume (GRV) in mechanically ventilated critically ill patients receiving enteral nutrition (EN). This prospective observational study included 56 enterally-fed critically ill patients in one-year period. All imaging procedures were done at 30-degree head-of-bed elevation and supine position on epigastric region of abdomen with 2.5–6 MHz convex-array probe just before routine GRV aspiration. The antral cross-sectional area (CSA) was calculated by measuring the anteroposterior (dAP) and craniocaudal diameters (dCC) of the gastric antrum. Total 283 ultrasonographic gastric antrum imaging procedures were done. In only eight (2.82%) attempts, the antrum could not be visualized due to inhibition from intra-gastric air or gas in the surrounding intestinal lumen. The calculated mean antral CSA was 568.15 ± 348.37 mm2 (103.43–2,846.30). The antral CSA correlated significantly with aspirated GRV, and the antral CSA increased linearly with increasing aspirated GRV (R2 = 0.73, p < 0.0001). In Receiver operating characteristic (ROC) analysis of antral CSA ≥ 920 mm2 (mean + 1*SD) for estimating aspirated GRV, the area under the curve (AUC) was 0.848 (95% CI, 0.76 ~ 0.93) (p < 0.0001), and ROC analysis of antral CSA to discriminate aspirated GRV ≥ 250 mL showed a significant relation (AUC = 0.969, 95% CI 0.94 ~ 0.99, p < 0.0001). Ultrasonographic measurement of gastric antral CSA is an easy and reliable bedside procedure to estimate GRV in critically ill patients receiving EN in 30-degree head-of-bed elevation and supine position. Trial registration number: NCT04413474, date of registration: June 17, 2020, retrospectively registered.
引用
收藏
页码:923 / 929
页数:6
相关论文
共 50 条
  • [1] Does ultrasonographic assessment of gastric antrum correlate with gastric residual volume in critically ill patients? A prospective observational study
    Taskin, Gurhan
    Inal, Volkan
    Yamanel, Levent
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2021, 35 (04) : 923 - 929
  • [2] Ultrasonographic assessment of preoperative gastric volume in patients with dyspepsia: a prospective observational study
    Yuming Tan
    Xianchun Wang
    Han Yang
    Chuanlong Pan
    Nanbo Luo
    Junjie Li
    Fang Yang
    Yanling Bei
    Zhen Cahilog
    Qian Chen
    Zhiheng Liu
    Xinping Yang
    [J]. BMC Anesthesiology, 22
  • [3] Ultrasonographic assessment of preoperative gastric volume in patients with dyspepsia: a prospective observational study
    Tan, Yuming
    Wang, Xianchun
    Yang, Han
    Pan, Chuanlong
    Luo, Nanbo
    Li, Junjie
    Yang, Fang
    Bei, Yanling
    Cahilog, Zhen
    Chen, Qian
    Liu, Zhiheng
    Yang, Xinping
    [J]. BMC ANESTHESIOLOGY, 2022, 22 (01)
  • [4] Serial Ultrasonographic-measurement of Gastric Residual Volume in Critically Ill Patients for Prediction of Gastric Tube Feed Intolerance
    Ankalagi, Basavaraj
    Singh, Preet Mohinder
    Rewari, Vimi
    Ramachandran, Rashmi
    Aggarwal, Richa
    Soni, Kapil Dev
    Das, Debashish
    Madhusudhan, Kumble Seetharama
    Srivastava, Deep Narayan
    Kaur, Manpreet
    Trikha, Anjan
    [J]. INDIAN JOURNAL OF CRITICAL CARE MEDICINE, 2022, 26 (09) : 987 - 992
  • [5] GASTRIC RESIDUAL VOLUME AND ASPIRATION IN CRITICALLY ILL PATIENTS RECEIVING GASTRIC FEEDINGS
    Metheny, Norma A.
    Schallom, Lynn
    Oliver, Dana A.
    Clouse, Ray E.
    [J]. AMERICAN JOURNAL OF CRITICAL CARE, 2008, 17 (06) : 512 - 519
  • [6] Gastric residual volume and the paracetamol gastric motility test in critically ill patients
    V Zidianakis
    Th Niarchou
    P Miriantheus
    E Mboutzouka
    G Baltopoulos
    [J]. Critical Care, 7 (Suppl 2):
  • [7] Ultrasound assessment of gastric volume in critically ill patients
    Hamada, S. R.
    Garcon, P.
    Ronot, M.
    Kerever, S.
    Paugam-Burtz, C.
    Mantz, J.
    [J]. INTENSIVE CARE MEDICINE, 2014, 40 (07) : 965 - 972
  • [8] Ultrasound assessment of gastric volume in critically ill patients
    S. R. Hamada
    P. Garcon
    M. Ronot
    S. Kerever
    C. Paugam-Burtz
    J. Mantz
    [J]. Intensive Care Medicine, 2014, 40 : 965 - 972
  • [9] Serial Ultrasonographic-measurement of Gastric Residual Volume in Critically Ill Patients for Prediction of Gastric Tube Feed Intolerance: Views
    Pratyusha, Kambagiri
    Jindal, Atul
    [J]. INDIAN JOURNAL OF CRITICAL CARE MEDICINE, 2023, 27 (01) : 79 - 79
  • [10] Feasibility and Predictive Value of Ultrasound Assessment of the Gastric Residual Volume in Surgical Critically Ill Patients: A Pilot Study
    Chatelon, Jeanne
    Bourillon, Camille
    Darmon, Helene
    Carbonne, Helene
    Chhor, Vibol
    Follin, Arnaud
    Cholley, Bernard
    Guinvarc'h, Alain
    Mantz, Jean
    Pirracchio, Romain
    [J]. CRITICAL CARE MEDICINE, 2016, 44 (12) : E1255 - E1257