Coaxial Dual-wavelength Interferometric Method for a Thermal Infrared Focal-plane-array with Integrated Gratings

被引:0
|
作者
Yuanfang Shang
Xiongying Ye
Liangcai Cao
Pengfei Song
Jinyang Feng
机构
[1] Institute of Instrument Science and Technology,Department of Precision Instrument
[2] Tsinghua University,Department of Precision Instrument
[3] Institute of Opto-electronic Engineering,undefined
[4] Tsinghua University,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Uncooled infrared (IR) focal-plane-array (FPA) with both large sensing range and high sensitivity is a great challenge due to the limited dynamic range of the detected signals. A coaxial dual-wavelength interferometric system was proposed here to detect thermal-induced displacements of an ultrasensitive FPA based on polyvinyl-chloride(PVC)/gold bimorph cantilevers and carbon nanotube (CNT)-based IR absorbing films. By alternately selecting the two displacement measurements performed by λ1 (=640 nm) and λ2 (=660 nm), the temperature measuring range with greater than 50% maximum sensitivity can be extended by eight-fold in comparison with the traditional single-wavelength mode. Meanwhile, the relative measurement error over the full measuring range is below 0.4%. In addition, it offers a feasible approach for on-line and on-wafer FPA characterization with great convenience and high efficiency.
引用
收藏
相关论文
共 50 条
  • [1] Coaxial Dual-wavelength Interferometric Method for a Thermal Infrared Focal-plane-array with Integrated Gratings
    Shang, Yuanfang
    Ye, Xiongying
    Cao, Liangcai
    Song, Pengfei
    Feng, Jinyang
    [J]. SCIENTIFIC REPORTS, 2016, 6
  • [2] Evaluation of infrared focal-plane-array detectors
    Gross, W
    Hierl, T
    Schulz, M
    [J]. HIGH TEMPERATURES-HIGH PRESSURES, 2001, 33 (02) : 183 - 188
  • [3] Correcting for focal-plane-array temperature dependence in microbolometer infrared cameras lacking thermal stabilization
    Nugent, Paul W.
    Shaw, Joseph A.
    Pust, Nathan J.
    [J]. OPTICAL ENGINEERING, 2013, 52 (06)
  • [4] Statistical recursive filtering for offset nonuniformity estimation in infrared focal-plane-array sensors
    Martin, Cesar San
    Torres, Sergio
    Pezoa, Jorge E.
    [J]. INFRARED PHYSICS & TECHNOLOGY, 2008, 51 (06) : 564 - 571
  • [5] Fourier transform infrared bacteria identification with the use of a focal-plane-array detector and microarray printing
    Kirkwood, J
    Al-Khaldi, SF
    Mossoba, MM
    Sedman, J
    Ismail, AA
    [J]. APPLIED SPECTROSCOPY, 2004, 58 (11) : 1364 - 1368
  • [6] A test method of thermal time constant for uncooled infrared focal plane array
    Liu Z.
    Zhao S.
    Zhao Z.
    Li Y.
    Zheng X.
    Zhang L.
    [J]. Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2019, 48 (12):
  • [7] Correcting for focal-plane-array temperature dependence in microbolometer infrared cameras lacking thermal stabilization (vol 52, 061304, 2013)
    Nugent, Paul W.
    Shaw, Joseph A.
    Pust, Nathan J.
    [J]. OPTICAL ENGINEERING, 2013, 52 (10)
  • [8] A compact polarization-integrated long wavelength infrared focal plane array based on In As/GaSb superlattice
    Jian ZHOU
    Yi ZHOU
    Ying SHI
    Fangfang WANG
    Zhicheng XU
    Zhizhong BAI
    Min HUANG
    Lulu ZHENG
    Zhaoming LIANG
    Yihong ZHU
    Qingqing XU
    Yiming SHEN
    Xiangxiao YING
    Jianxin CHEN
    [J]. Science China(Information Sciences), 2022, 65 (02) : 204 - 210
  • [9] Model-based Correlation Measure for Gain and Offset Nonuniformity in Infrared Focal-Plane-Array Sensors
    Martin, Cesar San
    Torres, Sergio
    [J]. WMSCI 2008: 12TH WORLD MULTI-CONFERENCE ON SYSTEMICS, CYBERNETICS AND INFORMATICS, VOL V, PROCEEDINGS, 2008, : 275 - +
  • [10] nBn extended short-wavelength infrared focal plane array
    Dehzangi, Arash
    Haddadi, Abbas
    Chevallier, Romain
    Zhang, Yiyun
    Razeghi, Manijeh
    [J]. OPTICS LETTERS, 2018, 43 (03) : 591 - 594