Value of SPECT/CT in Diagnostic I-131 MIBG Scintigraphy in Patients with Neuroblastoma

被引:8
|
作者
Theerakulpisut D. [1 ]
Raruenrom Y. [1 ]
Wongsurawat N. [1 ]
Somboonporn C. [1 ]
机构
[1] Division of Nuclear Medicine, Department of Radiology, Faculty of Medicine, Khon Kaen University, 123 Mittraparp highway, Muang, Khon Kaen
关键词
Diagnostic I-131 MIBG scintigraphy; MIBG; Neuroblastoma; Radionuclide imaging; SPECT/CT;
D O I
10.1007/s13139-018-0532-y
中图分类号
学科分类号
摘要
Purpose: Diagnostic I-131 MIBG scintigraphy is an important imaging modality for evaluation of patients with neuroblastoma (NB) especially in centers where I-123 MIBG is not available. Single photon emission computed tomography/computed tomography (SPECT/CT) could potentially improve lesion detection over planar scintigraphy, but studies regarding its usefulness as an add-on to diagnostic I-131 MIBG scintigraphy are limited. This study aimed to determine the usefulness and factors related to usefulness of SPECT/CT in diagnostic I-131 MIBG scintigraphy in NB patients. Methods: Usefulness of SPECT/CT for lesion detection, lesion localization, resolving suspicious findings, and clarifying the nature of lesions on anatomical imaging were retrospectively reviewed in 86 diagnostic planar I-131 MIBG scintigrams with add-on SPECT/CT. Results: SPECT/CT detected additional lesions in 23.2%(20/86), helped localize lesions in 21.1%(8/38), resolved suspicious findings in 85.7%(6/7), determined functional status of lesions on anatomical imaging in 94.4%(17/18), and changed diagnosis from a negative to a positive study in 19.5%(8/41). Independent predictors of SPECT/CT being useful included presence of suspicious findings on planar imaging (OR 99.08; 95% C.I. 6.99–1404.41; p = 0.001), positive findings on planar imaging (OR 4.61; 95% C.I. 1.05, 20.28; p < 0.001), and presence of structural lesions on anatomical imaging (OR 32.54; 95% C.I. 5.37–196.96; p < 0.001). Conclusion: SPECT/CT is a useful add-on to diagnostic planar I-131 MIBG scintigraphy. Predictors of usefulness of SPECT/CT include suspicious or positive findings on planar scintigraphy and the presence of structural lesions on anatomical imaging. © 2018, Korean Society of Nuclear Medicine.
引用
收藏
页码:350 / 358
页数:8
相关论文
共 50 条
  • [1] Comparison of Diagnostic Value of I-123 MIBG and High-Dose I-131 MIBG Scintigraphy Including Incremental Value of SPECT/CT Over Planar Image in Patients With Malignant Pheochromocytoma/Paraganglioma and Neuroblastoma
    Fukuoka, Makoto
    Taki, Junichi
    Mochizuki, Takafumi
    Kinuya, Seigo
    CLINICAL NUCLEAR MEDICINE, 2011, 36 (01) : 1 - 7
  • [2] Added value of SPECT/CT for correlation of MIBG scintigraphy and diagnostic CT in neuroblastoma and pheochromocytoma
    Rozovsky, Katia
    Koplewitz, Benjamin Z.
    Krausz, Yodphat
    Revel-Vilk, Shoshana
    Weintraub, Michael
    Chisin, Roland
    Klein, Martine
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (04) : 1085 - 1090
  • [3] Incremental diagnostic value of I-131SPECT/CT fusion imaging over I-131 planar scintigraphy in patients with thyroid carcinoma
    Sritara, C.
    Kositwatanarerk, A.
    Chotipanich, C.
    Utamakul, C.
    Chokesuwattanaskul, P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S303 - S303
  • [4] Incremental diagnostic value of SPECT/CT on I-131 scintigraphy in radioiodine therapy for patients with well differentiated thyroid carcinoma
    Maruoka, Yasuhiro
    Abe, Koichiro
    Baba, Shingo
    Sawamoto, Hirofumi
    Tanabe, Yoshitaka
    Sasaki, Masayuki
    Honda, Hiroshi
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [5] I-131 METAIODOBENZYLGUANIDINE SCINTIGRAPHY IN PATIENTS WITH NEUROBLASTOMA
    HIBI, S
    TODO, S
    IMASHUKU, S
    MIYAZAKI, T
    PEDIATRIC RADIOLOGY, 1987, 17 (04) : 308 - 313
  • [6] I-131 mIBG Scintigraphy Curie Versus SIOPEN Scoring: Prognostic Value in Stage 4 Neuroblastoma
    Riaz, Saima
    Bashir, Humayun
    Khan, Saadiya Javed
    Qazi, Abid
    MOLECULAR IMAGING AND RADIONUCLIDE THERAPY, 2018, 27 (03) : 121 - 125
  • [7] Diagnostic Value of I-131 NP-59 SPECT/CT Scintigraphy in Patients with Subclinical or Atypical Features of Primary Aldosteronism
    Chen, Yi-Chun
    Su, Yu-Chieh
    Wei, Chang-Kuo
    Chiu, Jainn-Shiun
    Tseng, Chih-En
    Chen, Shao-Jer
    Wang, Yuh-Feng
    JOURNAL OF BIOMEDICINE AND BIOTECHNOLOGY, 2011,
  • [8] Doughnut appearance on I-131 MIBG scintigraphy
    Ozcan, Z
    Erdem, S
    Akin, H
    Burak, Z
    Ozkilic, H
    CLINICAL NUCLEAR MEDICINE, 1996, 21 (08) : 654 - 655
  • [9] I-123 Ioflupane Brain SPECT and I-131 MIBG Myocardial Scintigraphy as Complementary Diagnostic Tools in Parkinsonism
    Samardzic, T.
    Petrovic, R.
    Relja, M.
    Telarovic, S.
    Miletic, V.
    Tezak, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S348 - S348
  • [10] The additional diagnostic value of I-131 SPECT/CT in differentiated thyroid carcinoma
    Mizutani, Youichi
    Nagamachi, Shigeki
    Nishii, Ryuichi
    Kiyohara, Shogo
    Wakamatsu, Hideyuki
    Fujita, Seigo
    Futami, Shigemi
    Tamura, Shozo
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55